The text of a manual · part 8 of 36
LS 5700/LS 5800 Product Reference Guide: Chapter 5 Parameter Menus, pages 65 to 74
Pages 65 to 74 of 352, from LS 5700/LS 5800 Product Reference Guide
The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol LS-5700 and Symbol LS-5800
Page 65
Chapter 5 Parameter Menus
Set All Defaults EAS Interlock
5-5 5-11 to 5-12
RS-232C Host Types
5-13 to 5-17
RS-232C Port Host Options Baud Rate Parity Check Parity Hardware Handshaking Software Handshaking Serial Response Time-out Stop Bit Select ASCII Format Serial Host RTS Line State Beep on <BEL>
5-19 to 5-55 5-20 to 5-27 5-28 to 5-32 5-33 to 5-34 5-35 to 5-41 5-42 to 5-46 5-47 5-48 to 5-49 5-50 to 5-51 5-52 to 5-53 5-54 to 5-55
RS-232C Port Auxiliary Options Baud Rate Parity Check Parity Hardware Handshaking Software Handshaking Serial Response Time-out Stop Bit Select ASCII Format Aux Serial RTS Line State
5-56 to 5-84 5-57 to 5-64 5-65 to 5-69 5-70 to 5-71 5-72 to 5-75 5-76 to 5-77 5-78 5-79 to 5-80 5-81 to 5-82 5-83 to 5-84
5-1
Page 66
LS 5700/LS 5800 Product Reference Guide Hand-Held Laser Scanner Options 5-85 to 5-91 Program Hand-Held Scanner Only 5-85 Program Primary Scanner Only 5-86 Program Hand-Held Scanner Only* 5-87 Program Primary Scanner Only* 5-88 Program All Scanners 5-89 Hand-Held Scanner Beeper 5-90 *Applies only to LS 2603MX/LS 3603MX and LS 3203 Code Types & Options UPC-A/ UPC-E EAN-8/EAN-13, Bookland, EAN, Supplementals UCC/EAN Coupon Code Random Weight Check Digit Code 128 Code 39 I 2 of 5 Codabar Custom Tailoring Scanning Range Internal Beeper RS-232C Port External Beeper Beeper Volume Beeper Frequency Time-out Between Decodes, Same Symbol Different Symbols Decode Buffering Rest Mode Sleep Mode Time Delay to Rest/Sleep Mode Primary Decode Session Time 5-2
5-92 to 5-144 5-92 to 5-95 5-96 to 5-104 5-105 to 5-106 5-107 to 5-109 5-110 to 5-114 5-115 to 5-125 5-126 to 5-134 5-135 to 5-144 5-145 to 5-168 5-145 to 5-147 5-148 to 5-149 5-150 to 5-151 5-152 to 5-154 5-155 to 5-157 5-158 5-159 5-160 to 5-161 5-162 5-163 5-164 to 5-167 5-168
Page 67
Parameter Menus Decode Options UPC/EAN Predecode Block UPC/EAN Security Level Linear UPC/EAN Decode Linear Supplemental Decode Decode Redundancy for UPC/EAN (only in Autodiscriminate Mode) UPC/EAN Decode Performance Linear Code Type Security Level Code 128 Decode Performance Code 39 Decode Performance
5-169 to 5-199 5-169 to 5-171 5-172 to 5-175 5-176 to 5-177 5-178 to 5-179
Data Transmission Formats UPC-A Check Digit UPC-E Check Digit UPC-A Preamble UPC-E Preamble Convert UPC-E to UPC-A EAN Zero Extend Convert EAN-8 to EAN-13 Type Convert I 2 of 5 to EAN-13 Transmit I 2 of 5 Check Digit Transmit Code 39 Check Digit Beep After Good Decode Intercharacter Delay Transmit Code ID Character Pause Duration Prefix/Suffix Values Scan Data Transmission Format Serial Data Transmission Format Ignore Unknown Characters Data Format Cancel
5-200 to 5-245 5-200 to 5-201 5-202 to 5-203 5-204 to 5-207 5-208 to 5-209 5-210 to 5-211 5-212 to 5-213 5-214 to 5-215 5-216 to 5-217 5-218 to 5-219 5-220 to 5-221 5-222 to 5-223 5-224 5-225 to 5-227 5-228 5-229 to 5-232 5-233 to 5-242 5-238 to 5-242 5-243 to 5-244 5-245
5-180 5-181 to 5-185 5-186 to 5-189 5-190 to 5-194 5-195 to 5-199
5-3
Page 68
LS 5700/LS 5800 Product Reference Guide Programming Utilities Numeric Bar Codes Cancel Enter Application Items
5-4
5-246 to 5-264 5-246 to 5-255 5-256 5-257 5-258 to 5-264
Page 69
Parameter Menus
Set Default Parameter Scanning this bar code returns all parameters to the values listed in the Default Table beginning on page 5-6.
SET ALL DEFAULTS
5-5
Page 70
LS 5700/LS 5800 Product Reference Guide
Default Table Table 5-1. Default Table Parameter
Default
Page
Disabled
5-12
Baud Rate
9600
5-26
Parity
Even
5-29
Check Parity
Enable
5-33
Hardware Handshaking
None
5-37
Software Handshaking
None
5-42
Serial Response Time-out
2.0 seconds
5-47
Stop Bit Select
One
5-49
ASCII Format
8-Bit
5-50
Host Serial Line State
High
5-53
Beep on <BEL>
Disable
5-55
Baud Rate
9600
5-63
Parity
Even
5-66
Check Parity
Enable
5-70
Hardware Handshaking
None
5-74
Software Handshaking
None
5-76
Serial Response Time-out
2.0 seconds
5-78
Stop Bit Select
One
5-79
EAS Interlock RS-232C Port Host Options
RS-232C Port Auxiliary Options
5-6
Page 71
Parameter Menus Table 5-1. Default Table (cont’d) Parameter
Default
Page
ASCII Format
8-Bit
5-82
Aux Serial Line State
Low
5-84
Programming Mode
Program Primary Scanner Only
5-86
Beep After Good Decode
Disable
5-91
UPC-A
Enable
5-92
UPC-E
Enable
5-94
EAN-8
Enable
5-96
EAN-13
Enable
5-98
Bookland EAN
Disable
5-101
Decode UPC/EAN Supplementals
Ignore
5-102
UPC/EAN Coupon Code
Disable
5-106
Random Weight Check Digit
Disable
5-107
Code 128
Enable
5-110
UCC/EAN-128
Enable
5-112
Lengths for Code 128
Any Length
5-114
Code 39
Enable
5-115
Code 39 Full ASCII Conversion
Disable
5-119
Set Length(s) for Code 39
5 to 55
5-120
Code 39 Check Digit Verification
Disable
5-125
Hand-Held Laser Scanner Options
Code Types & Options
5-7
Page 72
LS 5700/LS 5800 Product Reference Guide Table 5-1. Default Table (cont’d) Parameter
Default
Page
Interleaved 2 of 5
Disable
5-127
Set Length(s) for I 2 of 5
14
5-128
Codabar
Disable
5-136
Set Lengths for Codabar
5-55
5-137
CLSI Editing
Disable
5-142
NOTIS Editing
Disable
5-144
Scanning Range
Full
5-145
Internal Beeper
Enable
5-148
RS-232C Port External Beeper
Disable
5-151
Beeper Volume
High
5-154
Beeper Frequency
High
5-157
Time out between reads, same symbol
0.6 seconds
5-158
Time out between reads, different symbols
0.2 seconds
5-159
Decode Buffering
Disable
5-161
Time Delay to Rest/Sleep Mode
30 minutes
5-165
Primary Decode Session Time
2.0 seconds
5-168
Custom Tailoring
5-8
Page 73
Parameter Menus Table 5-1. Default Table (cont’d) Parameter
Default
Page
Decode Options Decode Security Measures: - UPC/EAN Predecode block
Reject
5-170
- UPC/EAN Security
Level 0
5-172
- Linear UPC/EAN Decode
Disable
5-177
- Linear Supplemental Decode Decode UPC/EAN Redundncy
Disable
5-179
7
5-180
UPC/EAN Decode Performance
Enable, Level 3
5-185
Linear Code Type Security
Level 1
5-186
Code 128 Decode Performance
Enable, Level 3
5-194
Code 39 Decode Performance
Enable, Level 3
5-199
(only when autodiscriminate mode is enabled)
(for fixed length only) Data Transmission Formatting Transmit UPC-A Check Digit
Enable
5-200
Transmit UPC-E Check Digit
Enable
5-202
UPC-A Preamble
System Char
5-205
UPC-E Preamble
System Char
5-208
Convert UPC-E to A
Disable
5-211
EAN-8 Zero Extend
Disable
5-213
Convert EAN-8 to EAN-13 Type
Type if EAN-13
5-214
Convert I 2 of 5 to EAN-13
Disable
5-217
5-9
Page 74
LS 5700/LS 5800 Product Reference Guide Table 5-1. Default Table (cont’d) Parameter
Default
Page
Transmit I 2 of 5 Check Digit
Disable
5-219
Transmit Code 39 Check Digit
Disable
5-221
Beep After Good Decode
Enable
5-222
Intercharacter Delay
0
5-224
Transmit Code ID Character
None
5-227
Pause Duration
0
5-228
Prefix/Suffix Values
7013 (<CR/LF>
5-229 for serial) Scan Data Transmission Format
Data as is
5-234
Serial Data Transmission Format
Data as is
5-239
Ignore Unknown Characters
Enable
5-243
5-10