Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 7 of 36

LS 5700/LS 5800 Product Reference Guide: Chapter 4 Maintenance and Specifications

Pages 55 to 64 of 352, from LS 5700/LS 5800 Product Reference Guide

The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol LS-5700 and Symbol LS-5800

Page 55

Chapter 4 Maintenance and Specifications Routine Maintenance Cleaning the exit window is the only maintenance required. A dirty or scratched window may affect scanning activity. • Remove any dirt particles with a damp cloth.

• Wipe the window with a tissue moistened with ammonia/water.

LS 5700 To change or clean the exit window: • Press window removal latch and rotate forward (Figure 4-1).

Window Removal Latch

Figure 4-1. Removing window from an LS 5700

To Clean: • Wipe clean the underside of the upper window. • Wipe clean the top surface of the lower window. • Re-install the window by snapping into place.

4-1

Page 56

LS 5700/LS 5800 Product Reference Guide

LS 5800 To change or clean the exit window:

• Insert a coin into the large screw heads on the front of the scanner and turn counter-clockwise (Figure 4-2).

Figure 4-2. Removing Window from an LS 5800

• Lift off the window. To Clean: • Wipe clean the underside of the upper window. • Wipe clean the top surface of the lower window. • Re-install the top cover by tightening the two large screws.

4-2

Page 57

Maintenance and Spcifications

Removal from Counter: • Remove the window as described on the previous page.

• Lift the unit out by the two lift straps (Figure 4-3).

Lift Straps

Figure 4-3. Removing the Scanner

Accessories The following accessories are available from Symbol Technologies. See your Symbol representative or re-seller for ordering information.

• LS 5700 Mounting Stand • LS 5800 In-counter Mounting Kit • LS 5800 Stainless steel top plate with various hardened window options

• LS 5700/LS 5800 External Beeper • Competitive Scanner Adapter Kit* • EAS Antenna kit - Pre-loaded on some models - Add-on kit for either model *Contact your Symbol representative for more information.

4-3

Page 58

LS 5700/LS 5800 Product Reference Guide

Technical Specifications Table 4-1. Technical Specifications Item Power Requirements Scanner System LS 5700 LS 5800 Angular Orientation Yaw Roll Pitch LS 5700 LS 5800

Description +5.0 VDC ± 5% Consumes 3.5 watts nominal 16-line, 4-direction dynamic cross pattern 18-line, 6-direction dynamic cross pattern -45° to +45° 360° -30° to +60° 0° to 90°

Decode Depth of Field

On 100% UPC symbols See Table 4-2.

Print Contrast Minimum

25% absolute dark/light reflectance differential, measured at 675 nm.

Ambient Light Immunity Fluorescent Incandescent Mercury Vapor Sodium Vapor Sunlight

4-4

450 ft. candles 450 ft. candles 450 ft. candles 450 ft. candles 9000 ft. candles

4844 lux 4844 lux 4844 lux 4844 lux 96876 lux

Page 59

Maintenance and Spcifications Table 4-1. Technical Specifications (cont’d) Item

Description

Operating Temperature

32° to 104°F

0° to 40°C

Operating Humidity

5% to 95% non-condensing

Storage Temperature

-40° to 140°F

Storage Humidity

5% to 95% non-condensing

Weight LS 5700 LS 5800

1.9 lbs 1.8 lbs

.86 kg .81 kg

Dimensions LS 5700 Depth Height Width LS 5800

3.82 in. 6.2 in. 5.97 in. See Table 4-3

9.7 cm 15.7 cm 15.2 cm

Cable Length

6 ft.

183 cm

-40° to 60°C

Table 4-2. LS 5700/LS 5800 Decode Range LS 5700

LS 5800

Full Range

10 in. 25.4 cm

6.7 in. 17.0 cm

Medium Range

7.0 in. 17.8 cm

6.0 in. 15.2 cm

Short Range

3.5 in. 8.9 cm

3.5 in. 8.9 cm

Decode range depends on contrast, density, orientation, and quality of the bar code being decoded.

4-5

Page 60

LS 5700/LS 5800 Product Reference Guide Table 4-3. LS 5800 Scanner Dimensions Model

Outer Window Type of Glass

Depth In. (cm)

Outer Width Length Window in. in. (cm) (Glass) Size (cm) in. (cm)

LS 5800-I200TN

Tempax

3.1 (7.62)

6 (15.24)

6 5x5 (15.24) (12.7 x 12.7)

LS 5800-I200TC

Tempax

3.1 (7.62)

6 (15.24)

6 5x5 (15.24) (12.7 x 12.7)

LS 5800-I210DN

Diamond coated

3.3 (8.4)

7.9 (20.1)

7.9 (20.1)

4.6 x 5.1 (11.7 x 12.9)

LS 5800-I210SN

Sapphire coated

3.3 (8.4)

7.9 (20.1)

7.9 (20.1)

4x5 (10.2 x 12.7)

LS 5800-I220SN

Sapphire coated

3.3 (8.4)

11.8 (30.)

8.8 (22.3)

5x4 (12.7 x 10.2)

LS 5800-I210SC

Sapphire coated

3.3 (8.4)

11.8 (30.)

8.8 (22.3)

5x4 (12.7 x 10.2)

4-6

Page 61

Maintenance and Spcifications Table 4-4. LS 5800 Bucket Dimensions Model

Top Plate Width Length In. In. (cm) (cm)

Depth In. (cm)

Standard (12-17206-xx)

7.87 (200)

7.87 (200)

3.16 (80.2)

LS 5000 Replacement (12-17207-xx)

8.5 (216)

11.65 (296)

3.16 (80.2)

Spectra-Physics Freedom Adaptor (12-17208-xx)

11.3 (287)

14.37 (365)

3.16 (80.2)

4-7

Page 62

LS 5700/LS 5800 Product Reference Guide

Beeper Definitions Table 4-5. Beeper Definitions Beeper Sequence

Indication

Standard Use 1 Beep - short high tone

A bar code symbol was decoded, or serial data was received.

Lo/med/hi tone

Power-on reset. Occurs immediately after the unit is turned on or after a system reset, indicating the system software is working properly. If three beeps occur during normal operation, it is due to a reset; any work in progress is lost. If this occurs often, contact the Symbol Support Center.

4 Beeps - long high tone

A format or transmission error has been detected in the serial data or in a scanned symbol. The data is ignored. This occurs if a unit is not properly configured. Check option settings.

5 Beeps - long high tone

Data conversion error.

4-8

Page 63

Maintenance and Spcifications Table 4-5. Beeper Definitions (cont’d) Beeper Sequence

Indication

Parameter Menu Scanning Lo/hi tone

Input error, incorrect bar code or “Cancel” scanned, wrong entry, incorrect bar code programming sequence; remain in program mode.

Hi/lo tone

Keyboard parameter selected. Enter value using bar code keypad.

Hi/lo/hi/lo tone

Successful program exit with change in the parameter setting.

Serial Communication 1 Beep - short high tone

Serial communication was successfully received, then transmitted to the host.

4 Beeps - short high tone

Serial communications error.

Hi/hi/hi/hi

Parity error.

4-9

Page 64

LS 5700/LS 5800 Product Reference Guide

4-10