Page 235

Parameter Menus

Decode Options Accept Predecode Block This option allows immediate decode of a new UPC/EAN bar code regardless of the previously decoded UPC/EAN bar code’s block content.

ACCEPT PREDECODE BLOCK

5-171

Page 236

LS 5700/LS 5800 Product Reference Guide

Decode Options UPC/EAN Security Level The LS 5700/LS 5800 offers four levels of decode security for UPC/EAN bar codes. Increasing levels of security are provided for decreasing levels of bar code quality. There is an inverse relationship between security and scanner aggressiveness, so be sure to choose only that level of security necessary for any given application. Level 0 This is the default setting which allows the scanner to operate in its most aggressive state, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes.

UPC/EAN SECURITY LEVEL 0

5-172

Page 237

Parameter Menus

Decode Options UPC/EAN Security Level Level 1 As bar code quality levels diminish, certain characters become prone to mis-decodes before others (i.e., 1, 2, 7, 8). If you are experiencing mis-decodes of poorly printed bar codes, and the mis-decodes are limited to these characters, select this security level.

UPC/EAN SECURITY LEVEL 1

5-173

Page 238

LS 5700/LS 5800 Product Reference Guide

Decode Options UPC/EAN Security Level Level 2 If you are experiencing mis-decodes of poorly printed bar codes, and the mis-decodes are not limited to characters 1, 2, 7, and 8, select this security level.

UPC/EAN SECURITY LEVEL 2

5-174

Page 239

Parameter Menus

Decode Options UPC/EAN Security Level Level 3 If you have tried Security Level 2, and are still experiencing misdecodes, select this security level. Be advised, selecting this option is an extreme measure against mis-decoding severely out of spec bar codes. Selection of this level significantly impairs the decoding ability of the scanner. If this level of security is necessary, you should try to improve the quality of your bar codes.

UPC/EAN SECURITY LEVEL 3

5-175

Page 240

LS 5700/LS 5800 Product Reference Guide

Decode Options Linear UPC/EAN Decode This option applies to code types containing two adjacent blocks (e.g. UPC-A, EAN-8, EAN-13). When enabled, a bar code is transmitted only when both the left and right blocks are successfully decoded within one laser scan. This option should be enabled when bar codes are in proximity to each other.

ENABLE LINEAR UPC/EAN DECODE

5-176

Page 241

Parameter Menus

Decode Options Disable Linear UPC/EAN Decode

DISABLE LINEAR UPC/EAN DECODE

5-177

Page 242

LS 5700/LS 5800 Product Reference Guide

Decode Options Linear Supplemental Decode This option applies to code types containing two or five character supplementals. When enabled, a bar code is transmitted only when both the supplemental block and its adjacent block are successfully decoded within one laser scan. This option should be enabled when bar codes are in proximity to each other.

ENABLE LINEAR SUPPLEMENTAL DECODE

5-178

Page 243

Parameter Menus

Decode Options Disable Linear Supplemental Decode

DISABLE LINEAR SUPPLEMENTAL DECODE

5-179

Page 244

LS 5700/LS 5800 Product Reference Guide

Decode Options Decode Redundancy for UPC/EAN (only in Autodiscriminate Mode) With Autodiscriminate UPC/EAN Supplementals selected, this option adjusts the number of times a symbol is decoded before transmission. The range is from two to thirty times. Ten or above is recommended when decoding a mix of UPC/EAN symbols with and without supplementals. Scan the bar code below to select a decode redundancy value. Next scan two numeric bar codes on pages 5-246 to 5-255 that represent the desired number of times. For single digit numbers, include a leading zero. If you make an error, or wish to change your selection, scan CANCEL on page 5-256.

DECODE REDUNDANCY for UPC/EAN