Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 24 of 36

LS 5700/LS 5800 Product Reference Guide: Chapter 5 Parameter Menus, pages 225 to 234

Pages 225 to 234 of 352, from LS 5700/LS 5800 Product Reference Guide

The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol LS-5700 and Symbol LS-5800

Page 225

Parameter Menus

Custom Tailoring Disable Decode Buffering When disabled, successive decodes are no longer buffered by the scanner. The scanner waits until a decoded symbol is transmitted to the host device before processing another symbol.

DISABLE DECODE BUFFERING

5-161

Page 226

LS 5700/LS 5800 Product Reference Guide

Custom Tailoring Rest Mode To choose a Rest Mode for the LS 5700/LS 5800, scan the bar code below. The default time is 30 minutes. That is, 30 minutes after a scan attempt, the scanner enters this mode. To change the time to rest mode, scan a bar code beginning on page 5-164.

REST MODE

5-162

Page 227

Parameter Menus

Custom Tailoring Sleep Mode The LS 5700 can be programmed to completely shut down. The default time is 30 minutes. That is, 30 minutes after a scan attempt, the scanner enters this mode. To change the time to sleep mode, scan a bar code beginning on page 5-164.

SLEEP MODE

5-163

Page 228

LS 5700/LS 5800 Product Reference Guide

Custom Tailoring Time Delay to Rest/Sleep Mode This parameter sets the time the scanner remains active after any scanning activity. Scan one of the four options. Depending on the selection, the scanner enters a rest/sleep mode 15, 30, 60, or 90 minutes after the last attempted decode. If you make a mistake, scan CANCEL on page 5-256.

15 MINUTES

5-164

Page 229

Parameter Menus

Custom Tailoring Time Delay to Rest/Sleep Mode

30 MINUTES

5-165

Page 230

LS 5700/LS 5800 Product Reference Guide

Custom Tailoring Time Delay to Rest/Sleep Mode

60 MINUTES

5-166

Page 231

Parameter Menus

Custom Tailoring Time Delay to Rest/Sleep Mode

90 MINUTES

5-167

Page 232

LS 5700/LS 5800 Product Reference Guide

Custom Tailoring Primary Decode Session Time This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in 0.1 second increments from 0.1 to 9.9 seconds. (Setting this between 1.0 and 3.0 seconds is recommended.) Scan the bar code below to select a new time-out. Next scan two numeric bar codes on pages 5-246 to 5-255, the first representing seconds, the second tenths of seconds. If you make an error, or wish to change your selection, scan CANCEL on page 5-256.

DECODE ATTEMPT DURATION

5-168

Page 233

Parameter Menus

Decode Options UPC/EAN Predecode Block UPC/EAN bar codes are made up of two blocks representing “left” and “right” halves. For example, bar code1234567890 is divided into left block “12345,” and right block “67890.” To maximize its aggressiveness, the scanner is capable of decoding a UPC/EAN symbol by “splicing” together a left block read by one of the 20 scan lines, and a right block read by another.

5-169

Page 234

LS 5700/LS 5800 Product Reference Guide

Decode Options Reject Predecode Block This option provides additional protection (beyond the embedded check digit) against mis-splicing a UPC/EAN block from a symbol that has just been decoded (but has not completely exited the scanner’s field of view), with a block from a new symbol that has just been presented to the scanner. This option requires the scanner to compare the new symbol against the symbol just decoded to see if there are common blocks. If either the left or right blocks match between symbols, the scanner rejects the common block for the period of time dictated by the TIME OUT BETWEEN DECODES - SAME SYMBOL parameter.

REJECT PREDECODE BLOCK

5-170