Page 1
Symbol Omnidirectional Scanner Advanced Programmer’s Guide Click on red text at any location in the manual to jump to the specified chapter, topic, or reference.
Table of Contents Chapter 1: Advanced Data Formatting Chapter 2: ADF Bar Codes Copyright
70-15600-01 Revision C June 1997
Page 2
Copyright 1997 by Symbol Technologies, Inc. All rights reserved. No part of this publication may be reproduced or used in any form, or by any electrical or mechanical means, without permission in writing from Symbol. This includes electronic or mechanical means, such as photocopying, recording, or information storage and retrieval systems. The material in this manual is subject to change without notice. Symbol reserves the right to make changes to any product to improve reliability, function, or design. Symbol does not assume any product liability arising out of, or in connection with, the application or use of any product, circuit, or application described herein. No license is granted, either expressly or by implication, estoppel, or otherwise under any patent right or patent, covering or relating to any combination, system, apparatus, machine, material, method, or process in which Symbol products might be used. An implied license only exists for equipment, circuits, and subsystems contained in Symbol products. Symbol Technologies, Inc. One Symbol Plaza Holtsville, N.Y. 11742-1300 FCC Information This device complies with Part 15 of the FCC rules, and Canadian RSS:210. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page 3
Contents Chapter 1. Advanced Data Formatting Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Criteria . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Input Source. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Code Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Code Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Message Containing A Specific Data String . . . . . . . 1-3 Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 Alternate Rule Sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 Rules Hierarchy (in Bar Codes) . . . . . . . . . . . . . . . . . . . . 1-10 Default Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11 Beeper Definitions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12 ADF Bar Code Menu Example . . . . . . . . . . . . . . . . . . . . . 1-14 Formatting Scan Data . . . . . . . . . . . . . . . . . . . . . . . . . 1-14 Rule 1: The Code 128 Scanning Rule . . . . . . . . . . . . 1-15 Rule 2: The UPC Scanning Rule . . . . . . . . . . . . . . . . 1-16 Formatting Magstripe Data (LS 5000/5100/5200) . 1-17 Rule 3: The Bank Credit Card Rule . . . . . . . . . . . . . 1-19 Rule 4: The Store Credit Card Rule . . . . . . . . . . . . . 1-19 Formatting Serial Data . . . . . . . . . . . . . . . . . . . . . . . . 1-22 Rule 5: The Deli Weight Scale Rule . . . . . . . . . . . . . 1-23
Chapter 2. ADF Bar Codes Special Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 Enable Programming . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 Save/Erase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 Rule Sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10 Input Source. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-19 Code Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-28 Code Types (LS 5000/5100/5200 Only) . . . . . . . . . 2-40 Code Lengths. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-53 Specific Data String. . . . . . . . . . . . . . . . . . . . . . . . . . . 2-83 Actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-85 i
Page 4
Character . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-85 Send Pause . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-88 Send Value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-89 Beeps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-95 Turn On/Off Rule Sets . . . . . . . . . . . . . . . . . . . . . . . 2-98 Send Characters/ Data . . . . . . . . . . . . . . . . . . . . . . 2-106 Skip Ahead/Back . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-133 Spaces & Zeros . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-154 Send Control Characters . . . . . . . . . . . . . . . . . . . . . 2-221 Send Keyboard Characters . . . . . . . . . . . . . . . . . . . 2-253 Send Alt Characters . . . . . . . . . . . . . . . . . . . . . . . . . 2-348 Send Special Characters . . . . . . . . . . . . . . . . . . . . . 2-380 Send Keypad Characters. . . . . . . . . . . . . . . . . . . . . 2-401 Send Extended Keyboard Characters . . . . . . . . . . 2-418 Send F Keys. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-437 Send PF Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-467 Numeric Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-497 Alphanumeric Keyboard . . . . . . . . . . . . . . . . . . . . . . . . 2-508 Disable Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-604 ii
Page 5
Chapter 1 Advanced Data Formatting Advanced Data formatting (ADF) is a means of customizing data before it is transmitted to your host device. Scanned data* can be edited to suit your particular requirements. Programming your scanner involves scanning a series of bar codes that represent the desired parameters. LS 5000, LS 5100 and LS 5200 series scanners have a secondary scanner port that can be used for programming using an attached hand-held scanner or wand. In order to program these scanners, you need to first scan the ENABLE PROGRAMMING bar code on page 2-3. When you have finished, you must then scan the DISABLE PROGRAMMING bar code on page 2-604. All other Symbol omnidirectional scanners can be programmed at any time and do not require these symbols. For these scanners, simply scan the bar codes for the parameters you wish to set. An Input Source must be selected first. A beeper table beginning on 1-12 will help guide you through the programming steps. Note: When using an LS 9100, the Primary Scanner Port (page 2-20) must be selected as the Input Source. *The LS 5000, LS 5100 and LS 5200 can also edit magstripe data.
1-1
Page 6
Symbol Omnidirectional Scanners: Advanced Data Formatting
Rules To build a rule, you must select Criteria and Actions. The rules you enter must be logically correct. Criteria include Input Source, Code Type, Code Length, and Message Containing a Specific Data String. Actions are any alterations related to, or affecting these Criteria. Criteria, Actions, and entire Rules may be erased by scanning the appropriate bar code.
Criteria Input Source Select a single input or multiple source to be affected by this customized programming format. An input source must be selected prior to creating any ADF rules.
Code Types Select any number of code types to be affected. All selected codes must be scanned in succession, prior to selecting other criteria. If you don't select a code type, all code types will be affected.
Code Length Define the number of characters the selected code type must contain. If you don't select a code length, selected code types of any length will be affected.
1-2
Page 7
Symbol Omnidirectional Scanners: Advanced Data Formatting
Message Containing A Specific Data String Select whether the formatting will affect data that begins with a specific character or data string, or contains a specific character or data string. Specific String at Start - Scan this bar code, then scan the desired character or characters (up to a total of 8) in the alphanumeric keyboard bar codes. Specific String, Any Location - Scan this bar code, then, using the numeric keypad, scan a two digit number representing the position (use a leading “zero” if necessary) Then scan the desired character or characters (up to a total of 8) on the alphanumeric keyboard, followed by the End of Message bar code. Any Message OK - By not scanning any bar code, all selected code types will be formatted, regardless of information contained.
1-3
Page 8
Symbol Omnidirectional Scanners: Advanced Data Formatting
Actions Select how to format the data for transmission. Send Data - Send all data that follows, send all data up to a specific character selected from the alphanumeric keyboard bar code, or send the next N characters. N = any number from 1 to 254, selected from the alphanumeric keyboard. Setup Field(s) - Select predefined magstripe fields (Track 1 or Track 2, Acct Nr., Exp Data MMYY/YYMM, or Customer Name), or define fields as follows: Move Cursor To a Character - Scan this bar code, then any printable ASCII character from the alphanumeric keyboard. Move Cursor to Start - Scan this bar code to move cursor to the beginning of the data. Move Cursor to Position “N” - Scan this bar code, then select the position to which you wish to move (1 to 254) from the numeric keypad. Move Cursor Ahead “N” Positions - Scan this bar code, then select the number of positions ahead you wish to move (0 to 254) from the numeric keypad. Move Cursor Back “N” Positions - Scan this bar code, then select the number of positions back you wish to move (0 to 254) from the numeric keypad.
1-4
Page 9
Symbol Omnidirectional Scanners: Advanced Data Formatting Move Cursor Past a Character - This parameter will move the cursor past all occurrences of a selected character. Scan this bar code, then select a character from the alphanumeric keyboard. Send Keystroke - Scan the “Send __” bar code for the keystroke you wish to send. Setup Pause - Set the Pause Duration parameter in the Parameter Menus section of the Product Reference Guide prior to entering ADF. To insert a pause, scan the Send Pause bar code. Modify Data - Modify data in the following ways: Remove All Spaces - To remove all spaces, scan this bar code. Crunch All Spaces - To leave one space between words, scan this bar code. This also removes all leading and trailing spaces. Turn off Space Removal - Scan this bar code to disable space removal. Pad Data on Left With Spaces - To pad data to the left, scan the bar code containing the desired number of spaces. This parameter is activated by Send commands. Remove Leading Zeros - Scan this bar code to remove all leading zeros. Turn off Zero Removal - Scan this bar code to disable the removal of zeros.
1-5
Page 10
Symbol Omnidirectional Scanners: Advanced Data Formatting Pad Data on Left With Zeros - To pad data to the left, scan the bar code containing the desired number of zeros. This parameter is activated by Send commands. Send Preset Value - Send Values 1 through 6 by scanning the appropriate bar code. These values must be set in the Prefix/Suffix parameter found in the Par;ameter Menus section of the Product Reference Guide. Value 1 = Scan Suffix Value 2 = Scan Prefix Value 3 = Magstripe Suffix Value 4 = Magstripe Prefix Value 5 = Serial Suffix Value 6 = Serial Prefix
1-6