Page 1
RS 2200/3200 Series
LS 4800
Quick Reference
Page 2
© 1997 - 1999 SYMBOL TECHNOLOGIES, INC. All rights reserved. Symbol reserves the right to make changes to any product to improve reliability, function, or design. Symbol does not assume any product liability arising out of, or in connection with, the application or use of any product, circuit, or application described herein. No license is granted, either expressly or by implication, estoppel, or otherwise under any patent right or patent, covering or relating to any combination, system, apparatus, machine, material, method, or process in which Symbol products might be used. An implied license only exists for equipment, circuits, and subsystems contained in Symbol products. Symbol is a registered trademark of Symbol Technologies, Inc. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. Symbol Technologies, Inc. One Symbol Plaza Holtsville, N.Y. 11742-1300 http://www.symbol.com Patents This product is covered by one or more of the following U.S. and foreign Patents: U.S. Patent No.4,360,798; 4,369,361; 4,387,297; 4,460,120; 4,496,831; 4,593,186; 4,603,262; 4,607,156; 4,652,750; 4,673,805; 4,736,095; 4,758,717; 4,816,660; 4,845,350; 4,896,026; 4,897,532; 4,923,281; 4,933,538; 4,992,717; 5,015,833; 5,017,765; 5,021,641; 5,029,183; 5,047,617; 5,103,461; 5,113,445; 5,130,520; 5,140,144; 5,142,550; 5,149,950; 5,157,687; 5,168,148; 5,168,149; 5,180,904; 5,229,591; 5,230,088; 5,235,167; 5,243,655; 5,247,162; 5,250,791; 5,250,792; 5,262,627; 5,262,628; 5,266,787; 5,278,398; 5,280,162; 5,280,163; 5,280,164; 5,280,498; 5,304,786; 5,304,788; 5,306,900; 5,321,246; 5,324,924; 5,337,361; 5,367,151; 5,373,148; 5,378,882; 5,396,053; 5,396,055; 5,399,846; 5,408,081; 5,410,139; 5,410,140; 5,412,198; 5,418,812; 5,420,411; 5,436,440; 5,444,231; 5,449,891; 5,449,893; 5,468,949; 5,471,042; 5,478,998; 5,479,000; 5,479,002; 5,479,441; 5,504,322; 5,519,577; 5,528,621; 5,532,469; 5,543,610; 5,545,889; 5,552,592; 5,578,810; 5,581,070; 5,589,679; 5,589,680; 5,608,202; 5,612,531; 5,619,028; 5,664,229; 5,668,803; 5,675,139; 5,693,929; 5,698,835; 5,705,800; 5,714,746; 5,723,851; 5,734,152; 5,734,153; 5,745,794; 5,754,587; 5,762,516; 5,763,863; 5,767,500; 5,789,728; 5,808,287; 5,811,785; 5,811,787; 5,815,811; 5,821,519; 5,821,520; 5,823,812; 5,828,050; 5,850,078; 5,861,615; 5,874,720; 5,875,415; 5,900,617; 5,902,989; 5,907,146; 5,912,450; 5,914,478; 5,917,173; 5,920,059; 5,923,025;D305,885; D341,584; D344,501; D359,483; D362,453; D363,700; D363,918; D370,478; D383,124; D391,250; D405,077; D406,581. Invention No. 55,358; 62,539; 69,060; 69,187 (Taiwan); No. 1,601,796; 1,907,875; 1,955,269 (Japan). European Patent 367,299; 414,281; 367,300; 367,298; UK 2,072,832; France 81/ 03938; Italy 1,138,713. rev. 7/99
Quick Reference
Page 3
1
Scanner Varieties LS 4800s are powered by a power supply or by host power, while LS 4900s are battery-powered versions. Each scanner has RS-232C or Synapse “Smart Cable” interface capability with the host device. If the cable is a Synapse “Smart Cable,” there is a separate Interface Guide for cabling instructions.
Page 4
2
Setup System Components The system includes one scanner and one interface cable (both general types are illustrated below). If the scanner is battery powered, it also includes a battery pack, as illustrated below.
LS 4800 Scanner RS-232C Cable
Power Supply
SynapseTM Adapter Cable
Battery Pack (for LS 4900)
LS 4800 / 4900 System Components
Quick Reference
Page 5
3
Installation: LS 4800 with RS-232C Host Device Connector
LS 4800 Scanner
Power Adapter Output Cable Connector
Power Supply
LS 4800 System Components 1. Switch off all devices to be connected to the LS 4800 scanning system. 2. Connect the output cable into the port at the base of the scanner’s handle. Use the end indicated in the diagram. • Plug in the modular connector. • Twist the collar clockwise to snap into place. 3. If external power is required, connect the power supply to the Power Adapter input port on the cable and then to a receptacle supplying AC power of the proper voltage level.
Page 6
4
Power Adapter On RS-232C Cable
Power Supply Connector
4. Plug the opposite end of the host interface cable into the receiving port on the host system. 5. Program all desirable host interface, decode, and communications parameters. Use the bar code menus in the Product Reference Guide. 6. Power up the host device.
Quick Reference
Page 7
5
Installation: LS 4800 with Synapse LS 4800 Scanner
Synapse Cable Power Supply Connector Synapse Adapter Cable
LS 4800 System Components 1. Switch off all devices to be connected to the LS 4800 scanning system. 2. Connect the output cable into the port at the base of the scanner’s handle. Use the end indicated in the diagram. • Plug in the modular connector. • Slide the collar up into the keys. 3. Follow additional instructions in the cable’s Interface Guide. Power is applied by the Synapse “Smart Cable” interface.
Page 8
6
Portable Operation: LS 4900 For portable operation, battery-operated LS 4900 scanners must be used with a portable terminal (e.g., PDT 3300). If you want to carry the portable terminal and scanner in holsters, the adjustable belt is important for making portable operation simple. Two holsters also can be very useful. One is available to hold the portable terminal to the belt, while a second holster, for the scanner, attaches directly to the belt.
Setup Procedure for Portable Operation 1. Switch off all devices to be connected to the LS 4900 scanner. 2. If you use the optional belt and holsters, thread the belt through a loop on the back of the portable terminal’s holster. Add the scanner holster in the same way, or use the belt clip. 3. Naturally, locate the equipment to suit left- or righthanded scanning preferences. 4. Adjust the belt to your size and buckle together the locking ends. Note that mounting the portable terminal upside down in the holster actually makes it more immediately accessible than mounting it right-side up.
Quick Reference
Page 9
7
Connect the System Components Plug the connector at the end of the LS 4900 scanner’s coil cord into the receiving port on the portable terminal.
Output Cable Joins Receiving Port on Portable Terminal
LS 4900 Basic Setup with Portable Terminal