Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 13 of 19

LS 4071 Product Reference Guide: Chapter 5 Parameter Menus, pages 95 to 104

Pages 95 to 104 of 168, from LS 4071 Product Reference Guide

The original document is the PDF (1.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol LS-4071

Page 95

Parameter Menus

Enable/Disable Code 93 To enable or disable Code 93, scan the appropriate bar code below.

ENABLE CODE 93

DISABLE CODE 93

5-51

Page 96

LS 4071 Product Reference Guide

Set Lengths for Code 93 Lengths for Code 93 may be set for any length, one or two discrete lengths, or lengths within a specific range. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. One Discrete Length - This option allows you to decode only those codes containing a selected length. For example, if you select Code 93 One Discrete Length, then scan 1, 4, only Code 93 symbols containing 14 characters are decoded. Numeric bar codes begin on page 5-98. If you make an error, or wish to change your selection, scan CANCEL on page 5-100.

CODE 93 - ONE DISCRETE LENGTH

Two Discrete Lengths - This option allows you to decode only those codes containing two selected lengths. For example, if you select Code 93 Two Discrete Lengths, then scan 0, 2, 1, 4, only Code 93 symbols containing 2 or 14 characters are decoded. Numeric bar codes begin on page 5-98. If you make an error, or wish to change your selection, scan CANCEL on page 5-100.

CODE 93 - TWO DISCRETE LENGTHS

5-52

Page 97

Parameter Menus

Set Lengths for Code 93 (Cont’d) Length Within Range - This option allows you to decode a code type within a specified range. For example to decode Code 93 symbols containing between 4 and 12 characters, first scan Code 93 Length Within Range. Then scan 0, 4, 1 and 2 (single digit numbers must always be preceded by a leading zero). Numeric bar codes begin on page 5-98. If you make an error, or wish to change your selection, scan CANCEL on page 5-100.

CODE 93 - LENGTH WITHIN RANGE

Any Length - Scanning this option allows you to decode Code 93 symbols containing any number of characters.

CODE 93 - ANY LENGTH

5-53

Page 98

LS 4071 Product Reference Guide

Enable/Disable Interleaved 2 of 5 To enable or disable Interleaved 2 of 5, scan the appropriate bar code below.

ENABLE INTERLEAVED 2 OF 5

DISABLE INTERLEAVED 2 OF 5

5-54

Page 99

Parameter Menus

Set Lengths for Interleaved 2 of 5 Lengths for I 2 of 5 may be set for any length, one or two discrete lengths, or lengths within a specific range. The length of a code refers to the number of characters (i.e., human readable characters) the code contains and includes check digits. One Discrete Length - This option allows you to decode only those codes containing a selected length. For example, if you select I 2 of 5 One Discrete Length, then scan 1, 4, the only I 2 of 5 symbols decoded are those containing 14 characters. Numeric bar codes begin on page 5-98. If you make an error, or wish to change your selection, scan CANCEL on page 5-100.

I 2 of 5 - ONE DISCRETE LENGTH

Two Discrete Lengths - This option allows you to decode only those codes containing two selected lengths. For example, if you select I 2 of 5 Two Discrete Lengths, then scan 0, 2, 1, 4, the only I 2 of 5 symbols decoded are those containing 2 or 14 characters. Numeric bar codes begin on page 5-98. If you make an error, or wish to change your selection, scan CANCEL on page 5100.

I 2 of 5 - TWO DISCRETE LENGTHS

5-55

Page 100

LS 4071 Product Reference Guide

Set Lengths for Interleaved 2 of 5 (Cont’d) Length Within Range - This option allows you to decode a code type within a specified range. For example to decode I 2 of 5 symbols containing between 4 and 12 characters, first scan I 2 of 5 Length Within Range. Then scan 0, 4, 1 and 2 (single digit numbers must always be preceded by a leading zero). Numeric bar codes begin on page 5-98. If you make an error, or wish to change your selection, scan CANCEL on page 5-100.

I 2 of 5 - LENGTH WITHIN RANGE

Any Length - Scanning this option allows you to decode I 2 of 5 symbols containing any number of characters. Note: Selecting this option may lead to misdecodes for I 2 of 5 codes.

I 2 of 5 - ANY LENGTH

5-56

Page 101

Parameter Menus

I 2 of 5 Check Digit Verification When enabled, this parameter checks the integrity of an I 2 of 5 symbol to ensure it complies a specified algorithm, either USS (Uniform Symbology Specification), or OPCC (Optical Product Code Council).

DISABLE

USS CHECK DIGIT

OPCC CHECK DIGIT

5-57

Page 102

LS 4071 Product Reference Guide

Transmit I 2 of 5 Check Digit Scan this symbol if you want to transmit the check digit with the data.

TRANSMIT I 2 of 5 CHECK DIGIT (ENABLE)

Do Not Transmit I 2 of 5 Check Digit Scan this symbol if you want to transmit the data without the check digit.

DO NOT TRANSMIT I 2 of 5 CHECK DIGIT (DISABLE)

5-58

Page 103

Parameter Menus

Convert I 2 of 5 to EAN-13 This parameter converts a 14 character I 2 of 5 code into EAN-13, and transmits to the host as EAN-13. In order to accomplish this, the I 2 of 5 code must be enabled, one length must be set to 14, and the code must have a leading zero and a valid EAN-13 check digit.

CONVERT I 2 of 5 to EAN-13 (ENABLE)

DO NOT CONVERT I 2 of 5 to EAN-13 (DISABLE)

5-59

Page 104

LS 4071 Product Reference Guide

Enable/Disable Discrete 2 of 5 To enable or disable Discrete 2 of 5, scan the appropriate bar code below.

ENABLE DISCRETE 2 OF 5

DISABLE DISCRETE 2 OF 5

5-60