Page 85

Parameter Menus

Enable/Disable Trioptic Code 39 Trioptic Code 39 symbols always contain six characters. Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously. If you get an error beep when enabling Trioptic Code 39, disable Code 39 Full ASCII and try again. To enable or disable Trioptic Code 39, scan the appropriate bar code below.

ENABLE TRIOPTIC CODE 39

DISABLE TRIOPTIC CODE 39

5-41

Page 86

LS 4071 Product Reference Guide

Set Lengths for Code 39 Lengths for Code 39 may be set for any length, one or two discrete lengths, or lengths within a specific range. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. If Code 39 Full ASCII is enabled, Length Within a Range or Any Length are the preferred options. One Discrete Length - This option allows you to decode only those codes containing a selected length. For example, if you select Code 39 One Discrete Length, then scan 1, 4, only Code 39 symbols containing 14 characters are decoded. Numeric bar codes begin on page 5-98. If you make an error, or wish to change your selection, scan CANCEL on page 5-100.

CODE 39 - ONE DISCRETE LENGTH

Two Discrete Lengths - This option allows you to decode only those codes containing two selected lengths. For example, if you select Code 39 Two Discrete Lengths, then scan 0, 2, 1, 4, only Code 39 symbols containing 2 or 14 characters are decoded. Numeric bar codes begin on page 5-98. If you make an error, or wish to change your selection, scan CANCEL on page 5-100.

CODE 39 - TWO DISCRETE LENGTHS

5-42

Page 87

Parameter Menus

Set Lengths for Code 39 (Cont’d) Length Within Range - This option allows you to decode a code type within a specified range. For example to decode Code 39 symbols containing between 4 and 12 characters, first scan Code 39 Length Within Range. Then scan 0, 4, 1 and 2 (single digit numbers must always be preceded by a leading zero). Numeric bar codes begin on page 5-98. If you make an error, or wish to change your selection, scan CANCEL on page 5-100.

CODE 39 - LENGTH WITHIN RANGE

Any Length - Scanning this option allows you to decode Code 39 symbols containing any number of characters.

CODE 39 - ANY LENGTH

5-43

Page 88

LS 4071 Product Reference Guide

Code 39 Check Digit Verification When enabled, this parameter checks the integrity of a Code 39 symbol to ensure it complies with specified algorithms. Only those code 39 symbols which include a modulo 43 check digit are decoded when this parameter is enabled.

ENABLE CODE 39 CHECK DIGIT

DISABLE CODE 39 CHECK DIGIT

5-44

Page 89

Parameter Menus

Transmit Code 39 Check Digit Scan this symbol if you want to transmit the check digit with the data.

TRANSMIT CODE 39 CHECK DIGIT (ENABLE)

Do Not Transmit Code 39 Check Digit Scan this symbol if you want to transmit the data without the check digit.

DO NOT TRANSMIT CODE 39 CHECK DIGIT (DISABLE)

5-45

Page 90

LS 4071 Product Reference Guide

Enable/Disable Code 39 Full ASCII To enable or disable Code 39 Full ASCII, scan the appropriate bar code below. When enabled, the ASCII character set assigns a code to letters, punctuation marks, numerals, and most control keystrokes on the keyboard. The first 32 codes are non-printable and are assigned to keyboard control characters such as BACKSPACE and RETURN. The other 96 are called printable codes because all but SPACE and DELETE produce visible characters. Code 39 Full ASCII interprets the bar code special character ($ + % /) preceding a Code 39 character and assigns an ASCII character value to the pair. For example, when Code 39 Full ASCII is enabled and a +B is scanned, it is interpreted as b, %J as ?, and $H emulates the keystroke BACKSPACE. Scanning ABC$M will output the keystroke equivalent of ABC ENTER. Refer to the ASCII table in Appendix A. Code 39 Full ASCII and Trioptic Code 39 cannot be enabled simultaneously. If you get an error beep when enabling Code 39 Full ASCII, disable Trioptic Code 39 and try again. The scanner does not autodiscriminate between Code 39 and Code 39 Full ASCII.

ENABLE CODE 39 FULL ASCII

DISABLE CODE 39 FULL ASCII

5-46

Page 91

Parameter Menus

Code 39 Buffering (Scan & Store) When you select the scan and store option, all Code 39 symbols having a leading space as a first character are temporarily buffered in the unit to be transmitted later. The leading space is not buffered. Decode of a valid Code 39 symbol with no leading space causes transmission in sequence of all buffered data in a first-in first-out format, plus transmission of the “triggering” symbol. See the following pages for further details. When the scan and transmit option is selected, decoded Code 39 symbols without leading spaces are transmitted without being stored in the buffer. Scan and Store affects Code 39 decodes only. If you select scan and store, it is recommended that you configure the scanner to decode Code 39 symbology only.

BUFFER CODE 39 (ENABLE)

DO NOT BUFFER CODE 39 (DISABLE)

5-47

Page 92

LS 4071 Product Reference Guide

Code 39 Buffering (Scan & Store) While there is data in the transmission buffer, deleting Code 39 buffering capability via the parameter menu is not allowed. The buffer holds 200 bytes of information. To allow disabling of Code 39 buffering, first force the buffer transmission (see Transmit Buffer) or clear the buffer. Both the CLEAR BUFFER and TRANSMIT BUFFER bar codes are length 1. Be sure Code 39 length is set to include length 1.

Buffer Data To buffer data, Code 39 buffering must be enabled, and a symbol must be read with a space immediately following the start pattern. • Unless symbol overflows the transmission buffer, the unit gives lo/hi beep to indicate successful decode and buffering. See Overfilling Transmission Buffer. • Unit adds the message, excluding the leading space to the transmission buffer. • No transmission occurs.

Clear Transmission Buffer To clear the transmission buffer, read a symbol which contains only a start character, a dash (minus), and a stop character. • Unit issues a short hi/lo/hi beep to signal that the transmission buffer has been erased, and no transmission has occurred. • Unit erases the transmission buffer. • No transmission occurs.

CLEAR BUFFER

5-48

Page 93

Parameter Menus

Code 39 Buffering (Scan & Store) Transmit Buffer To transmit the buffer, read a symbol containing either the first or second condition: 1. Only a start character, a plus (+), and a stop character. • The unit signals that the transmission buffer has been sent (a lo/hi beep). • Unit sends the buffer. • Unit clears the buffer.

TRANSMIT BUFFER

2. A Code 39 bar code with leading character other than a space. • The unit signals a good decode and buffering of that decode has occurred by giving a hi/lo beep. • Unit transmits the buffer. • Unit signals that the buffer has been transmitted with a lo/hi beep.

Overfilling Transmission Buffer If the symbol just read will result in an overflow of the transmission buffer: • Unit indicates that the symbol has been rejected by issuing three long, high beeps. • No transmission occurs. Data in buffer is not affected.

Attempt to Transmit an Empty Buffer If the symbol just read was the transmit buffer symbol and the Code 39 buffer is empty: • A short lo/hi/lo beep signals that the buffer is empty. • No transmission occurs. • The buffer remains empty. 5-49

Page 94

LS 4071 Product Reference Guide

Convert Code 39 to Code 32 Scan this symbol if you want to convert Code 39 to Code 32.

CONVERT CODE 39 TO CODE 32 (ENABLE)

Note: Code 39 must be enabled in order for this parameter to function.

Do Not Convert Code 39 to Code 32 Scan this symbol if you do not want to convert Code 39 to Code 32.

DO NOT CONVERT CODE 39 TO CODE 32 (DISABLE)

5-50