Page 88
LS 3070 Product Reference Guide: Programming
Parameter Menu Scanning Beeper Sequence
Indication
1 Beep - short high tone
Correct entry scanned or correct menu sequence performed.
1 Beep - lo/hi tone
Input error, incorrect bar code or CANCEL scanned, wrong entry, incorrect bar code programming sequence; remain in program mode.
1 Beep - hi/lo tone
Keyboard parameter selected. Enter value using bar code keypad.
1 Beep - hi/lo/hi/lo tone
Successful program exit with change in the parameter setting.
Code 39 Scan And Store Beeper Sequence
Indication
1 Beep - hi/lo tone
New Code 39 data was entered into the buffer.
3 Beeps - long high tone
Code 39 buffer is full.
1 Beep - lo/hi/lo tone
The buffer was erased, or there was an attempt to transmit an empty buffer. When the Code 39 buffer was empty, the base station read a command to clear or to transmit a Code 39 buffer.
2 Beeps - long high tone
Error in data transmission.
1 Beep - lo/hi tone
A successful transmission of buffered data.
6-25
Page 89
LS 3070 Product Reference Guide: Programming
Code 39 Buffering While there is data in the transmission buffer, deleting Code 39 buffering capability via the parameter menu is not allowed. To allow disabling of Code 39 buffering, first force the buffer transmission (see Transmit Buffer on page 6-27) or clear the buffer.
Buffer Data To buffer data, Code 39 buffering must be enabled, and a symbol must be read with a space immediately following the start pattern. • Unless symbol overflows the transmission buffer, unit gives hi/lo beep to indicate successful decode and buffering. See Overfilling Transmission Buffer on page 6-27. • Unit adds the message, excluding the leading space to the transmission buffer. • No transmission will occur.
Clear Transmission Buffer To clear the transmission buffer, read a symbol which contains only a start character, a dash (minus), and a stop character. • Unit issues a short hi/lo/hi beep to signal that the transmission buffer has been erased, and no transmission has occurred. • Unit erases the transmission buffer. • No transmission will occur.
.
6-26
Page 90
LS 3070 Product Reference Guide: Programming
Transmit Buffer To transmit the buffer, read a symbol containing either the first or second condition: 1. Only a start character, a plus (+), and a stop character. • The unit signals that the transmission buffer has been sent (a hi/lo beep). • Unit sends the buffer. • Unit clears the buffer.
2. A Code 39 bar code with leading character other than a space. • The unit signals a good decode and buffering of that decode has occurred by giving a hi/lo beep. • Unit transmits the buffer. • Unit signals that the buffer has been transmitted with a lo/hi beep.
Overfilling Transmission Buffer If the symbol just read will result in an overflow of the transmission buffer: • Unit indicates that the symbol has been rejected by issuing three long, high beeps. • No transmission will occur. Data in buffer is not affected.
Attempt to Transmit an Empty Buffer If the symbol just read was the transmit buffer symbol and the Code 39 buffer is empty: • A short lo/hi/lo beep signals that the buffer is empty. • No transmission occurs. • The buffer remains empty.
6-27
Page 91
LS 3070 Product Reference Guide: Programming
Default Table Table 6-3. Defaults Parameter
Default
Host Interface
See default table, page 6-31
Code Types
All
Code Lengths: Code 39 Code 128 Codabar I 2 of 5 D 2 of 5 MSI Plessey
1 to 55 3 to 55 2 to 55 14 14 1 to 55
Decode Options Transmit UPC-A Check Digit Transmit UPC-E Check Digit Convert UPC-E to UPC-A EAN Zero Extend Transmit No Decode Message Decode UPC/EAN Supplemental ITF-14/EAN-13 Conversion Transmit Code 39 Check Digit MSI Plessey Check Digit Buffer Code 39 Beeper Volume Beep After Good Decode UPC/EAN Security Level Decode Redundancy
Enabled Enabled Disabled Disabled Disabled Disabled Enabled Disabled One Disabled High Enabled 0 0
UPC-A Preamble
System Character
UPC-E Preamble
System Character
Pause Duration
0
Prefix/Suffix Values**
7013 (<Enter> for wedges, <CR/LF> for serial devices)
Magstripe Data Transmission Format
Data as is
6-28
Page 92
LS 3070 Product Reference Guide: Programming
Table 6-3. Defaults Parameter
Default
Scan Data Transmission Format
Data as is
Laser Control: Laser On Time-out
3 Sec
RS-232C Options Baud Rate Parity Check Parity Hardware Handshaking Software Handshaking Serial Response Time-out Stop Bit Select ASCII Data Format RTS Line State
9600 Odd Enabled None None 2.0 Sec Two 7 Bit Low
Intercharacter Delay
0
Transmit Code ID Character
Disabled
Transmit AIM Code ID
Disabled
Ignore Unknown Characters
Enabled
OCIA Transmit Time-out
3 Sec
OCIA Clock Polarity
Falling
NCR 2152 Fast Transmit
Disabled
IBM 4683/4 Magstripe Communications
Enabled
International Keypad Emulation
Disabled
International Keypad Emulation Fast Xmit
Disabled
National Keyboard Type
U.S. English
Set Transmission Frequency (Channel)
50
Wait for Host Interface Response Time
00
6-29
Page 93
LS 3070 Product Reference Guide: Programming
** Prefix/Suffix values only apply when the selected transmission format uses them. For example, if you select the default setting for Scan Data Transmission Format (Data As Is), any prefix or suffix selected is not recognized, since the format requires neither.
6-30
Page 94
LS 3070 Product Reference Guide: Programming
Terminal Specific RS-232C Defaults Two RS-232C hosts are set up with their own parameter default settings. Selecting the ICL or Nixdorf RS-232C terminal will set the defaults listed below. These defaults take precedence over standard defaults. So, if you’ve selected Nixdorf RS-232C, then select the standard defaults, the Nixdorf defaults will still take precedence. Table 6-4. Terminal-Specific RS-232 Defaults Parameter
Standard
ICL
NIXDORF
Fixed Host Select
No Host
RS-232C
RS-232C
Transmit Code ID
No
Yes
Yes
Data as is
Data/Suffix
Data/Suffix
CR/LF (7013)
CR (1013)
CR (1013)
Baud Rate
9600
9600
9600
Parity
Even
Even
Odd
Check Parity
Enabled
Enabled
Enabled
Hardware Handshaking
None
None
None
Software Handshaking
None
None
None
Serial Response Time-out
2 Sec.
2 Sec.
2 Sec.
Stop Bit Select
Two
One
One
ASCII Format
7-Bit
8-Bit
8-Bit
Beep On <BEL>
Disabled
Disabled
Disabled
RTS Line State
Low
High
Low
RS-232C UPC-A Code ID
“A”
“A”
“A”
RS-232C UPC-E Code ID
“A”
“E0”
“C0”
RS-232C EAN-8 Code ID
“A”
“FF”
“B”
RS-232C EAN-13 Code ID
“A”
“F”
“A”
RS-232C Code 39 Code ID
“B”
“C”
“M”
RS-232C Codabar Code ID
“C”
“N”
“N”
Data Transmission Format Suffix
6-31
Page 95
LS 3070 Product Reference Guide: Programming
Table 6-4. Terminal-Specific RS-232 Defaults Parameter
Standard
ICL
NIXDORF
RS-232C Code 128 Code ID
“D”
None
“K”
RS-232C I 2 of 5 Code ID
“F”
“I”
“I”
RS-232C MSI/Plessey Code ID
“J”
None
“O”
6-32