Page 88

LS 3070 Product Reference Guide: Programming

Parameter Menu Scanning Beeper Sequence

Indication

1 Beep - short high tone

Correct entry scanned or correct menu sequence performed.

1 Beep - lo/hi tone

Input error, incorrect bar code or CANCEL scanned, wrong entry, incorrect bar code programming sequence; remain in program mode.

1 Beep - hi/lo tone

Keyboard parameter selected. Enter value using bar code keypad.

1 Beep - hi/lo/hi/lo tone

Successful program exit with change in the parameter setting.

Code 39 Scan And Store Beeper Sequence

Indication

1 Beep - hi/lo tone

New Code 39 data was entered into the buffer.

3 Beeps - long high tone

Code 39 buffer is full.

1 Beep - lo/hi/lo tone

The buffer was erased, or there was an attempt to transmit an empty buffer. When the Code 39 buffer was empty, the base station read a command to clear or to transmit a Code 39 buffer.

2 Beeps - long high tone

Error in data transmission.

1 Beep - lo/hi tone

A successful transmission of buffered data.

6-25

Page 89

LS 3070 Product Reference Guide: Programming

Code 39 Buffering While there is data in the transmission buffer, deleting Code 39 buffering capability via the parameter menu is not allowed. To allow disabling of Code 39 buffering, first force the buffer transmission (see Transmit Buffer on page 6-27) or clear the buffer.

Buffer Data To buffer data, Code 39 buffering must be enabled, and a symbol must be read with a space immediately following the start pattern. • Unless symbol overflows the transmission buffer, unit gives hi/lo beep to indicate successful decode and buffering. See Overfilling Transmission Buffer on page 6-27. • Unit adds the message, excluding the leading space to the transmission buffer. • No transmission will occur.

Clear Transmission Buffer To clear the transmission buffer, read a symbol which contains only a start character, a dash (minus), and a stop character. • Unit issues a short hi/lo/hi beep to signal that the transmission buffer has been erased, and no transmission has occurred. • Unit erases the transmission buffer. • No transmission will occur.

.

6-26

Page 90

LS 3070 Product Reference Guide: Programming

Transmit Buffer To transmit the buffer, read a symbol containing either the first or second condition: 1. Only a start character, a plus (+), and a stop character. • The unit signals that the transmission buffer has been sent (a hi/lo beep). • Unit sends the buffer. • Unit clears the buffer.

2. A Code 39 bar code with leading character other than a space. • The unit signals a good decode and buffering of that decode has occurred by giving a hi/lo beep. • Unit transmits the buffer. • Unit signals that the buffer has been transmitted with a lo/hi beep.

Overfilling Transmission Buffer If the symbol just read will result in an overflow of the transmission buffer: • Unit indicates that the symbol has been rejected by issuing three long, high beeps. • No transmission will occur. Data in buffer is not affected.

Attempt to Transmit an Empty Buffer If the symbol just read was the transmit buffer symbol and the Code 39 buffer is empty: • A short lo/hi/lo beep signals that the buffer is empty. • No transmission occurs. • The buffer remains empty.

6-27

Page 91

LS 3070 Product Reference Guide: Programming

Default Table Table 6-3. Defaults Parameter

Default

Host Interface

See default table, page 6-31

Code Types

All

Code Lengths: Code 39 Code 128 Codabar I 2 of 5 D 2 of 5 MSI Plessey

1 to 55 3 to 55 2 to 55 14 14 1 to 55

Decode Options Transmit UPC-A Check Digit Transmit UPC-E Check Digit Convert UPC-E to UPC-A EAN Zero Extend Transmit No Decode Message Decode UPC/EAN Supplemental ITF-14/EAN-13 Conversion Transmit Code 39 Check Digit MSI Plessey Check Digit Buffer Code 39 Beeper Volume Beep After Good Decode UPC/EAN Security Level Decode Redundancy

Enabled Enabled Disabled Disabled Disabled Disabled Enabled Disabled One Disabled High Enabled 0 0

UPC-A Preamble

System Character

UPC-E Preamble

System Character

Pause Duration

0

Prefix/Suffix Values**

7013 (<Enter> for wedges, <CR/LF> for serial devices)

Magstripe Data Transmission Format

Data as is

6-28

Page 92

LS 3070 Product Reference Guide: Programming

Table 6-3. Defaults Parameter

Default

Scan Data Transmission Format

Data as is

Laser Control: Laser On Time-out

3 Sec

RS-232C Options Baud Rate Parity Check Parity Hardware Handshaking Software Handshaking Serial Response Time-out Stop Bit Select ASCII Data Format RTS Line State

9600 Odd Enabled None None 2.0 Sec Two 7 Bit Low

Intercharacter Delay

0

Transmit Code ID Character

Disabled

Transmit AIM Code ID

Disabled

Ignore Unknown Characters

Enabled

OCIA Transmit Time-out

3 Sec

OCIA Clock Polarity

Falling

NCR 2152 Fast Transmit

Disabled

IBM 4683/4 Magstripe Communications

Enabled

International Keypad Emulation

Disabled

International Keypad Emulation Fast Xmit

Disabled

National Keyboard Type

U.S. English

Set Transmission Frequency (Channel)

50

Wait for Host Interface Response Time

00

6-29

Page 93

LS 3070 Product Reference Guide: Programming

** Prefix/Suffix values only apply when the selected transmission format uses them. For example, if you select the default setting for Scan Data Transmission Format (Data As Is), any prefix or suffix selected is not recognized, since the format requires neither.

6-30

Page 94

LS 3070 Product Reference Guide: Programming

Terminal Specific RS-232C Defaults Two RS-232C hosts are set up with their own parameter default settings. Selecting the ICL or Nixdorf RS-232C terminal will set the defaults listed below. These defaults take precedence over standard defaults. So, if you’ve selected Nixdorf RS-232C, then select the standard defaults, the Nixdorf defaults will still take precedence. Table 6-4. Terminal-Specific RS-232 Defaults Parameter

Standard

ICL

NIXDORF

Fixed Host Select

No Host

RS-232C

RS-232C

Transmit Code ID

No

Yes

Yes

Data as is

Data/Suffix

Data/Suffix

CR/LF (7013)

CR (1013)

CR (1013)

Baud Rate

9600

9600

9600

Parity

Even

Even

Odd

Check Parity

Enabled

Enabled

Enabled

Hardware Handshaking

None

None

None

Software Handshaking

None

None

None

Serial Response Time-out

2 Sec.

2 Sec.

2 Sec.

Stop Bit Select

Two

One

One

ASCII Format

7-Bit

8-Bit

8-Bit

Beep On <BEL>

Disabled

Disabled

Disabled

RTS Line State

Low

High

Low

RS-232C UPC-A Code ID

“A”

“A”

“A”

RS-232C UPC-E Code ID

“A”

“E0”

“C0”

RS-232C EAN-8 Code ID

“A”

“FF”

“B”

RS-232C EAN-13 Code ID

“A”

“F”

“A”

RS-232C Code 39 Code ID

“B”

“C”

“M”

RS-232C Codabar Code ID

“C”

“N”

“N”

Data Transmission Format Suffix

6-31

Page 95

LS 3070 Product Reference Guide: Programming

Table 6-4. Terminal-Specific RS-232 Defaults Parameter

Standard

ICL

NIXDORF

RS-232C Code 128 Code ID

“D”

None

“K”

RS-232C I 2 of 5 Code ID

“F”

“I”

“I”

RS-232C MSI/Plessey Code ID

“J”

None

“O”

6-32