The text of a manual · part 5 of 44
LS 2200/2208 Product Reference Guide: Chapter 1 Getting Started
Pages 21 to 26 of 376, from LS 2200/2208 Product Reference Guide
The original document is the PDF (3.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol LS-2208
Page 21
Chapter 1 Getting Started Introduction The LS 2200 scanner combines excellent scanning performance and advanced ergonomics to provide the best value in a lightweight laser scanner. Whether used as a hand-held scanner or in hands-free mode in a stand, the scanner ensures comfort and ease of use for extended periods of time.
Figure 1-1. LS 2200 Scanner Note: Unless otherwise noted, the term LS 2200 refers to all versions of the scanner.
1-1
Page 22
LS 2200/2208 Product Reference Guide
Here’s what each member of the LS 2200 family offers you: •
LS 2208 - This decoded scanner supports the following interfaces: •
Standard RS-232 connection to a host. Proper communications of the scanner with the host is set up by scanning bar code menus.
•
Keyboard Wedge connection to a host. Scanned data is interpreted by your host as keystrokes. • International Keyboards supported: North America, German, French, French International, Spanish, Italian, Swedish, British, Japanese, and PortugueseBrazilian.
•
Wand Emulation connection to a host. The scanner is connected to a portable data terminal, a controller, or host which collects the data as wand data and decodes it.
•
Connection to IBM 468X/469X hosts. Proper communications of the scanner with the IBM terminal is set up by scanning bar codes.
•
USB connection to a host. The scanner autodetects a USB host and defaults to the HID keyboard interface type. Other USB interface types are selectable by scanning programming bar code menus. • International Keyboards supported (for Windows environment): North America, German, French, French International, Spanish, Italian, Swedish, British, Portuguese-Brazilian, and Japanese.
•
•
Synapse capability which allows you to connect to a wide variety of host systems using a Synapse and Synapse adapter cable to connect to a host. The scanner autodetects a Synapse.
•
Configuration via 123Scan.
LS 2200 - This undecoded version of the scanner provides connectivity to portable terminals and external interface controllers.
Unpacking Your Scanner Remove the scanner from its packing and inspect it for damage. If the scanner was damaged in transit, call the Symbol Support Center at one of the telephone numbers listed on page xiv. KEEP THE PACKING. It is the approved shipping container and should be used if you ever need to return your equipment for servicing.
1-2
Page 23
Getting Started
Setting Up the Scanner Installing the Interface Cable 1. Plug the interface cable modular connector into the cable interface port on the bottom of the scanner handle. (See Figure 1-2.) 2. Gently tug the cable to ensure the connector is properly secured. 3. Connect the other end of the interface cable to the host (see the specific host chapter for information on host connections).
Cable interface port
Interface cable modular connector
To host
Figure 1-2. Installing the Cable Note: Different cables are required for different hosts. The connectors illustrated in each host chapter are examples only. Your connectors may be different than those illustrated, but the steps to connect your scanner remain the same.
1-3
Page 24
LS 2200/2208 Product Reference Guide
Connecting Power (if required) If your host does not provide power to the scanner, you will need an external power connection to the scanner: 1. Connect the interface cable to the bottom of the scanner, as described in Installing the Interface Cable on page 1-3. 2. Connect the other end of the interface cable to the host (refer to your host manual to locate the correct port). 3. Plug the power supply into the power jack on the interface cable. Plug the other end of the power supply into an AC outlet.
Configuring Your Scanner Two methods are available to configure your scanner: using the bar codes included in this manual, or the 123Scan configuration program. Refer to Chapter 4, User Preferences for information about programming your scanner using bar code menus. Refer to Chapter 10, 123Scan to configure your scanner using this configuration program. A helpfile is available in the program. The scanner supports RS-232, IBM 468X/469X, Keyboard Wedge, Wand Emulation, USB, and Synapse to interface to a host system. Each host specific chapter describes how to set up each of these connections.
1-4
Page 25
Getting Started
Connecting a Synapse Cable Interface Note: See the Synapse Interface Guide provided with your Synapse cable for detailed setup instructions. Symbol’s Synapse Smart Cables enable interfacing to a variety of hosts. The appropriate Synapse cable has the built-in intelligence to detect the host to which it is connected. To host
Synapse adapter cable
Synapse Smart Cable To scanner
Figure 1-3. Synapse Cable Connection 1. Plug the Synapse adapter cable (p/n 25-32463-xx) into the bottom of the scanner, as described in Installing the Interface Cable on page 1-3. 2. Align the ‘S’ on the Synapse adapter cable with the ‘S’ on the Synapse Smart Cable and plug the cable in. 3. Connect the other end of the Synapse Smart Cable to the host.
Removing the Interface Cable To remove the interface cable: 1. Unplug the installed cable’s modular connector by depressing the connector clip with the tip of a screwdriver. 2. Carefully slide out the cable. 3. Follow the steps for Installing the Interface Cable on page 1-3 to connect a new cable.
1-5
Page 26
LS 2200/2208 Product Reference Guide
1-6