The text of a manual · part 28 of 44
LS 2200/2208 Product Reference Guide: Chapter 12 Miscellaneous Scanner Options
Pages 231 to 242 of 376, from LS 2200/2208 Product Reference Guide
The original document is the PDF (3.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol LS-2208
Page 231
Chapter 12 Miscellaneous Scanner Options Introduction This chapter includes commonly used bar codes to customize how your data is transmitted to your host device. In addition to these bar codes for data formatting, refer to each host chapter for the appropriate host connections and host device features for your scanner. Refer to Chapter 11, Symbologies and Chapter 13, Advanced Data Formatting for customizing data for transmission to your host device. Before programming, follow the instructions in Chapter 1, Getting Started. Your scanner is shipped with the settings shown in the Miscellaneous Scanner Options Default Table on page 12-3 (also see Appendix A, Standard Default Parameters for all host device and miscellaneous scanner defaults). If the default values suit your requirements, programming may not be necessary. Features values are set by scanning single bar codes or short bar code sequences.
12-1
Page 232
LS 2200/2208 Product Reference Guide
Scanning Sequence Examples In most cases you need only scan one bar code to set a specific parameter value. Parameters, such as Prefix Value, require that you scan several bar codes in the proper sequence. Refer to each individual parameter for descriptions of this procedure.
Errors While Scanning Unless otherwise specified, if you make an error during a scanning sequence, just re-scan the correct parameter.
12-2
Page 233
Miscellaneous Scanner Options
Miscellaneous Default Parameters Table 12-1 lists the defaults for miscellaneous scanner options parameters. If you wish to change any option, scan the appropriate bar code(s) provided in the Miscellaneous Scanner Parameters section beginning on page 12-4. Note: See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.
Table 12-1. Miscellaneous Scanner Options Default Table Parameter
Default
Page Number
Transmit Code ID Character
None
12-4
Prefix Value
7013 <CR><LF>
12-5
Suffix Value
7013 <CR><LF>
12-5
Scan Data Transmission Format
Data as is
12-6
FN1 Substitution Values
Set
12-9
Transmit “No Read” Message
Disable
12-10
Synapse Interface
Standard
12-11
Transmit Code ID Character
None
12-4
12-3
Page 234
LS 2200/2208 Product Reference Guide
Miscellaneous Scanner Parameters Transmit Code ID Character A Code ID character identifies the code type of a scanned bar code. This may be useful when the scanner is decoding more than one code type. In addition to any single character prefix already selected, the Code ID character is inserted between the prefix and the decoded symbol. The user may select no Code ID character, a Symbol Code ID character, or an AIM Code ID character. For Code ID Characters, see Symbol Code Identifiers on page B-1 and AIM Code Identifiers on page B-3.
Symbol Code ID Character
AIM Code ID Character
*None
12-4
Page 235
Miscellaneous Scanner Options
Prefix/Suffix Values A prefix/suffix may be appended to scan data for use in data editing. These values are set by scanning a four-digit number (i.e., four bar codes) that corresponds to key codes for various terminals. See Table E-1 on page E-1 for conversion information. Numeric bar codes begin on page D-1 in Appendix D. If you make an error or wish to change your selection, scan Cancel on page D-5.
Scan Prefix
Scan Suffix
12-5
Page 236
LS 2200/2208 Product Reference Guide
Scan Data Transmission Format To change the Scan Data Transmission Format, scan the Scan Options bar code below. Then select one of four options: •
Data As Is
•
<DATA> <SUFFIX>
•
<PREFIX> <DATA>
•
<PREFIX> <DATA> <SUFFIX>
When you have made your selection, scan the Enter bar code on page 12-8. If you make a mistake, scan the Data Format Cancel bar code on page 12-8. If you need to have a carriage return/enter after each bar code scanned, scan the following bar codes in order: 1. <SCAN OPTIONS> 2. <DATA> <SUFFIX> 3. Enter (on page 12-8)
Scan Options
12-6
Page 237
Miscellaneous Scanner Options
Scan Data Transmission Format(continued)
*Data As Is
<DATA> <SUFFIX>
<PREFIX> <DATA>
12-7
Page 238
LS 2200/2208 Product Reference Guide
Scan Data Transmission Format (continued)
<PREFIX> <DATA> <SUFFIX>
Enter
Data Format Cancel
12-8
Page 239
Miscellaneous Scanner Options
FN1 Substitution Values The Wedge and USB HID Keyboard hosts support a FN1 Substitution feature. When enabled any FN1 character (0x1b) in an EAN128 barcode is substituted with a value. This value defaults to 7013 (Enter Key) 1. To select a FN1 Substitution Value, scan the bar code below.
Set FN1 Substitution Value
2. Look up the keystroke desired for FN1 Substitution in the ASCII Character Set table for the currently installed host interface. Enter the 4-digit "ASCII Value" by scanning each digit in the Numeric Bar Codes on page D-1. 3. To correct an error or change the selection, scan CANCEL. To enable FN1 Substitution for Wedge, scan the Enable Keyboard Wedge FN1 Substitution bar code on page 5-15. To enable FN1 Substitution for USB HID Keyboard, scan the Enable USB Keyboard FN1 Substituition bar code on page 7-12.
12-9
Page 240
LS 2200/2208 Product Reference Guide
Transmit “No Read” Message Scan a bar code below to select whether or not a “No Read” message is transmitted. When enabled, the characters NR are transmitted when a bar code is not decoded. When disabled, if a symbol does not decode, nothing is sent to the host.
Enable No Read
*Disable No Read
12-10
Page 241
Miscellaneous Scanner Options
Synapse Interface The auto-detection of a Synapse cable needs to vary in duration depending on the type of Synapse connection. If a scanner is connected to another scanner using a Synapse cable then the Auxiliary Synapse Port connection should be used. In all other cases, where the cable is used, the default setting is recommended. Should the user want to disconnect and reconnect the scanner from a Synapse cable that is connected to a live host a Synapse, then the "Plug and Play" setting should be used. This setting should not be changed from the default if an on-board wedge host is enabled.
*Standard Synapse Connection
Auxiliary Synapse Port Connection
“Plug and Play” Synapse Connection
12-11
Page 242
LS 2200/2208 Product Reference Guide
12-12