Page 181

Symbologies

Enable/Disable Trioptic Code 39 Trioptic Code 39 is a variant of Code 39 used in the marking of computer tape cartridges. Trioptic Code 39 symbols always contain six characters. To enable or disable Trioptic Code 39, scan the appropriate bar code below.

Enable Trioptic Code 39

*Disable Trioptic Code 39

Note: Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously.

11-29

Page 182

LS 2200/2208 Product Reference Guide

Convert Code 39 to Code 32 Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry. Scan the appropriate bar code below to enable or disable converting Code 39 to Code 32. Note: Code 39 must be enabled in order for this parameter to function.

Enable Convert Code 39 to Code 32

*Disable Convert Code 39 to Code 32

11-30

Page 183

Symbologies

Code 32 Prefix Scan the appropriate bar code below to enable or disable adding the prefix character “A” to all Code 32 bar codes. Note: Convert Code 39 to Code 32 must be enabled for this parameter to function.

Enable Code 32 Prefix

*Disable Code 32 Prefix

11-31

Page 184

LS 2200/2208 Product Reference Guide

Set Lengths for Code 39 The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Lengths for Code 39 may be set for any length, one or two discrete lengths, or lengths within a specific range. If Code 39 Full ASCII is enabled, Length Within a Range or Any Length are the preferred options. Note: When setting lengths for different bar code types by scanning single digit numbers, single digit numbers must always be preceded by a leading zero. One Discrete Length - This option allows you to decode only those Code 39 symbols containing a selected length. Lengths are selected from the numeric bar codes beginning on page D-1 in Appendix D. For example, to decode only Code 39 symbols with 14 characters, scan Code 39 - One Discrete Length, then scan 1 followed by 4. If you make an error or wish to change your selection, scan Cancel on page D-5.

Code 39 - One Discrete Length

Two Discrete Lengths - This option allows you to decode only those Code 39 symbols containing either of two selected lengths. Lengths are selected from the numeric bar codes beginning on page D-1 in Appendix D. For example, to decode only those Code 39 symbols containing either 2 or 14 characters, select Code 39 - Two Discrete Lengths, then scan 0, 2, 1, and then 4. If you make an error or wish to change your selection, scan Cancel on page D-5.

Code 39 - Two Discrete Lengths

11-32

Page 185

Symbologies

Set Lengths for Code 39 (continued) Length Within Range - This option allows you to decode a Code 39 symbol with a specific length range. The length range is selected from numeric bar codes beginning on page D-1 in Appendix D. For example, to decode Code 39 symbols containing between 4 and 12 characters, first scan Code 39 - Length Within Range. Then scan 0, 4, 1, and 2 (single digit numbers must always be preceded by a leading zero). If you make an error or wish to change your selection, scan Cancel on page D-5.

Code 39 - Length Within Range

Any Length - Scanning this option allows you to decode Code 39 symbols containing any number of characters within the scanner capability.

Code 39 - Any Length

11-33

Page 186

LS 2200/2208 Product Reference Guide

Code 39 Check Digit Verification When this feature is enabled, the scanner checks the integrity of all Code 39 symbols to verify that the data complies with specified check digit algorithm. Only those Code 39 symbols which include a modulo 43 check digit are decoded when this feature is enabled. This feature should only be enabled if your code 39 symbols contain a Modulo 43 check digit.

Enable Code 39 Check Digit

*Disable Code 39 Check Digit

11-34

Page 187

Symbologies

Transmit Code 39 Check Digit Scan a bar code below to transmit Code 39 data with or without the check digit.

Transmit Code 39 Check Digit (Enable)

*Do Not Transmit Code 39 Check Digit (Disable)

Note: Code 39 Check Digit Verification must be enabled for this parameter to function.

11-35

Page 188

LS 2200/2208 Product Reference Guide

Code 39 Full ASCII Conversion Code 39 Full ASCII is a variant of Code 39 which pairs characters to encode the full ASCII character set. To enable or disable Code 39 Full ASCII, scan the appropriate bar code below. Refer to Table 5-2 on page 5-19 and for the mapping of Code 39 characters to ASCII values.

Enable Code 39 Full ASCII

*Disable Code 39 Full ASCII

Note: Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously.

Note:

11-36

Code 39 Full ASCII to Full ASCII Correlation is host-dependent, and is therefore described in the "ASCII Character Set" Table for the appropriate interface. The Wedge Host conversion table can be found on 5-3, USB Host conversion table can be found on 7-4, and RS-232 Host conversion table can be found on 6-3.

Page 189

Symbologies

Code 39 Buffering (Scan & Store) This feature allows the scanner to accumulate data from multiple Code 39 symbols. When you select the Scan and Store option (Buffer Code 39), all Code 39 symbols having a leading space as a first character are temporarily buffered in the unit to be transmitted later. The leading space is not buffered. Decode of a valid Code 39 symbol with no leading space causes transmission in sequence of all buffered data in a first-in first-out format, plus transmission of the “triggering” symbol. See the following pages for further details. When the Do Not Buffer Code 39 option is selected, all decoded Code 39 symbols are transmitted immediately without being stored in the buffer. This feature affects Code 39 only. If you select Buffer Code 39, we recommend that you configure the scanner to decode Code 39 symbology only.

Buffer Code 39 (Enable)

*Do Not Buffer Code 39 (Disable)

While there is data in the transmission buffer, selecting Do Not Buffer Code 39 is not allowed. The buffer holds 200 bytes of information. To disable Code 39 buffering when there is data in the transmission buffer, first force the buffer transmission (see Transmit Buffer on page 11-39) or clear the buffer.

11-37

Page 190

LS 2200/2208 Product Reference Guide

Buffer Data To buffer data, Code 39 buffering must be enabled and a Code 39 symbol must be read with a space immediately following the start pattern. •

Unless the data overflows the transmission buffer, the scanner issues a lo/hi beep to indicate successful decode and buffering. (For overflow conditions, see Overfilling Transmission Buffer.)

•

The scanner adds the decoded data excluding the leading space to the transmission buffer.

•

No transmission occurs.

Clear Transmission Buffer To clear the transmission buffer, scan the Clear Buffer bar code below, which contains only a start character, a dash (minus), and a stop character. •

The scanner issues a short hi/lo/hi beep.

•

The scanner erases the transmission buffer.

•

No transmission occurs.

Clear Buffer

Note: The Clear Buffer contains only the dash (minus) character. In order to scan this command, be sure Code 39 length is set to include length 1.

11-38