Page 151

Chapter 10 123Scan Introduction This chapter includes the bar code you must scan to use the 123Scan program. 123Scan is a Windows® based utility that allows the scanner to be setup and programmed with all parameters including Advanced Data Formatting (ADF) Rules. An ADF rule allows bar code data to be modified before it is sent on to the host. This ensures compatibility between bar coded data and the host application; the scanner is programmed rather than modifying the host software. Scanners can be programmed via PC download or by scanning a sheet of bar codes generated by the utility. Scanner programming is saved in a file that can be distributed electronically by e-mail. A help file is built into the program 123Scan.

Communication With the 123Scan PC Based Configuration Tool In order to communicate with the 123Scan program, which runs on a PC with Windows, use an RS-232 cable to connect the scanner to the PC (see Connecting an RS-232 Interface on page 6-2). You will need: •

PC with Windows

•

Scanner

•

RS-232 cable.

10-1

Page 152

LS 2200/2208 Product Reference Guide

123Scan Parameter In order to communicate with the 123Scan program, load 123Scan, included in the documentation CD-ROM, onto your PC and scan the bar code below. Refer to 123Scan instructions for programming your scanner. Note: Scanning this bar code enables the 123Scan interface on the scanner.

123Scan Configuration

10-2

Page 153

Chapter 11 Symbologies Introduction This chapter describes all symbology features and provides the programming bar codes necessary for selecting these features for your LS 2200 scanner. Before programming, follow the instructions in Chapter 1, Getting Started. Note: To program the undecoded LS 2200 scanner, refer to the programming guide for your external interface controller or portable terminal. Your scanner is shipped with the settings shown in the Symbology Default Table on page 11-3 (also see Appendix A, Standard Default Parameters for all host device and miscellaneous scanner defaults). If the default values suit your requirements, programming may not be necessary. Features values are set by scanning single bar codes or short bar code sequences. To return all features to their default values, all you need to do is scan the Set All Defaults bar code on page 4-4. If you are not using a Synapse or USB cable you must select a host type. Refer to each host chapter for specific host information.

11-1

Page 154

LS 2200/2208 Product Reference Guide

Scanning Sequence Examples In most cases you need only scan one bar code to set a specific parameter value. For example, if you want to transmit bar code data without the UPC-A check digit, simply scan the Do Not Transmit UPC-A Check Digit bar code listed under Transmit UPC-A/UPC-E/UPCE1 Check Digit on page 11-14. The scanner issues a short high beep and the LED turns green, signifying a successful parameter entry. Other parameters, such as Set Length(s) for D 2 of 5 require that you scan several bar codes in the proper sequence. Refer to the individual parameter, like Set Length(s) for D 2 of 5, for this procedure.

Errors While Scanning Unless otherwise specified, if you make an error during a scanning sequence, just re-scan the correct parameter.

11-2

Page 155

Symbologies

Symbology Default Parameters Table 11-1 lists the defaults for all symbologies parameters. If you wish to change any option, scan the appropriate bar code(s) provided in the Symbologies Parameters section beginning on 11-7. Note: See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.

Table 11-1. Symbology Default Table Default

Page Number

UPC-A

Enable

11-7

UPC-E

Enable

11-7

UPC-E1

Disable

11-8

EAN-8/JAN 8

Enable

11-9

EAN-13/JAN 13

Enable

11-9

Bookland EAN

Disable

11-10

Decode UPC/EAN/JAN Supplementals (2 and 5 digits)

Ignore

11-12

UPC/EAN/JAN Supplemental Redundancy

7

11-13

Transmit UPC-A Check Digit

Enable

11-14

Transmit UPC-E Check Digit

Enable

11-14

Transmit UPC-E1 Check Digit

Enable

11-15

Parameter UPC/EAN

11-3

Page 156

LS 2200/2208 Product Reference Guide

Table 11-1. Symbology Default Table (Continued) Parameter

Default

Page Number

UPC-A Preamble

System Character

11-16

UPC-E Preamble

System Character

11-16

UPC-E1 Preamble

System Character

11-18

Convert UPC-E to A

Disable

11-20

Convert UPC-E1 to A

Disable

11-20

EAN-8/JAN-8 Extend

Disable

11-21

UPC/EAN Security Levels

0

11-22

UCC Coupon Extended Code

Disable

11-24

Code 128

Enable

11-25

ISBT 128

Enable

11-27

UCC/EAN-128

Enable

11-26

Code 39

Enable

11-28

Trioptic Code 39

Disable

11-29

Convert Code 39 to Code 32 (Italian Pharamacy Code)

Disable

11-30

Code 32 Prefix

Disable

11-31

Set Length(s) for Code 39

2 to 55

11-32

Code 39 Check Digit Verification

Disable

11-34

Transmit Code 39 Check Digit

Disable

11-35

Code 128

Code 39

11-4

Page 157

Symbologies

Table 11-1. Symbology Default Table (Continued) Parameter

Default

Page Number

Code 39 Full ASCII Conversion

Disable

11-36

Buffer Code 39

Disable

11-37

Code 93

Disable

11-41

Set Length(s) for Code 93

4 to 55

11-42

Code 11

Disable

11-44

Set Lengths for Code 11

4 to 55

11-45

Code 11 Check Digit Verification

Disable

11-47

Transmit Code 11 Check Digit(s)

Disable

11-48

Interleaved 2 of 5 (ITF)

Enable

11-49

Set Lengths for I 2 of 5

14

11-50

I 2 of 5 Check Digit Verification

Disable

11-52

Transmit I 2 of 5 Check Digit

Disable

11-53

Convert I 2 of 5 to EAN 13

Disable

11-54

Discrete 2 of 5

Disable

11-55

Set Length(s) for D 2 of 5

12

11-56

Code 93

Code 11

Interleaved 2 of 5 (ITF)

Discrete 2 of 5 (DTF)

11-5

Page 158

LS 2200/2208 Product Reference Guide

Table 11-1. Symbology Default Table (Continued) Default

Page Number

Codabar

Disable

11-58

Set Lengths for Codabar

5 to 55

11-59

CLSI Editing

Disable

11-61

NOTIS Editing

Disable

11-62

MSI

Disable

11-63

Set Length(s) for MSI

1 to 55

11-64

MSI Check Digits

One

11-66

Transmit MSI Check Digit

Disable

11-67

MSI Check Digit Algorithm

Mod 10/Mod 10

11-68

RSS 14

Disable

11-69

RSS Limited

Disable

11-69

RSS Expanded

Disable

11-69

Convert RSS to UPC/EAN

Disable

11-71

1

11-72

Parameter Codabar (NW - 7)

MSI

RSS (Reduced Space Symbology)

Symbology - Specific Security Levels Redundancy Level

11-6

Page 159

Symbologies

UPC/EAN Enable/Disable UPC-A/UPC-E To enable or disable UPC-A or UPC-E, scan the appropriate bar code below.

*Enable UPC-A

Disable UPC-A

*Enable UPC-E

Disable UPC-E

11-7

Page 160

LS 2200/2208 Product Reference Guide

Enable/Disable UPC-E1 UPC-E1 is disabled by default. To enable or disable UPC-E1, scan the appropriate bar code below. Note: UPC-E1 is not a UCC (Uniform Code Council) approved symbology.

Enable UPC-E1

*Disable UPC-E1

11-8