Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 7 of 13

LS 1004 Scanner Product Reference Guide: Chapter 4 Programming The LS 1004, pages 37 to 45

Pages 37 to 45 of 96, from LS 1004 Scanner Product Reference Guide

The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol LS-1004

Page 37

Chapter 4 Programming The LS 1004 Chapter Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3 RS-232 Host Type Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6 RS-232C Code ID Characters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7 Scanning Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7 Scanning Sequence Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7 Errors While Scanning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8 Parameter Descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9 Set Parameter Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9 Host Interface Select . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9 RS-232 Host Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10 Power On Beep Enable/Disable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11 Beeper after Decode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11 Beeper Tone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12 Beeper Volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12 Decode Attempt Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13 Operating Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14 Aggressive Scan Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14 Transmit “No Decode” Message. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15 Decode Redundancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15 Code Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15 UPC/EAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-17 Code 128 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-22 Code 39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-23 Code 93 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-24 Interleaved 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-24 Discrete 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-27

4-1

Page 38

LS 1004 Product Reference Guide

Codabar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-29 Data Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-30 RS-232C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-34

4-2

Page 39

Programming the LS 1004

Introduction This chapter provides information on how to program the LS 1004 scanner. Before programming the scanner, follow the instructions in Set-Up on page 1-3. The Table 4-1 illustrates the default values with which the scanner is shipped. If the default values suit your requirements, scan the SET ALL DEFAULTS barcode. This will set the scanner to the default parameters. Changing the scanner’s programmable parameters is accomplished by scanning the bar codes provided in this section. The following table lists the defaults for all parameters. If you wish to change any option, scan the appropriate bar code(s).

Table 4-1. Default Table Parameter

Default

Page Number

Set Default Parameter

All Defaults

4-9

Host Interface Select

RS-232C

4-9

Power On Beep

Disable

4-11

Beep after Decode

Enable

4-11

Beeper Tone

Middle

4-12

Beeper Volume

High Level

4-12

Decode Attempt Time

1 second

4-13

Operating Mode

Low Power

4-14

Aggressive Scan Mode

Disable

4-14

Transmit “No Decode” message

No Message

4-15

Decode Redundancy

Disable

4-15

Code Types

All

4-16

Enable/Disable UPC/EAN

Enable

4-17

Transmit UPC-A Check Digit

Enable

4-17

Transmit UPC-E Check Digit

Enable

4-17

UPC/EAN

4-3

Page 40

LS 1004 Product Reference Guide

Table 4-1. Default Table (Continued) Parameter

Default

Page Number

Decode UPC Only

Disable

4-17

Convert UPC-E to UPC-A

Disable

4-18

EAN Zero Extend

Disable

4-18

Decode UPC/EAN Supplemental

No Supplemental

4-19

UPC-E Preamble

System Character

4-20

UPC-A Preamble

System Character

4-20

UPC/EAN Security Level

Level 0

4-21

Enable/Disable Code 128

Enable

4-22

Send Code 128 Function Character

Disable

4-22

Enable/Disable Code 39

Enable

4-23

Code 39 modulo 43 check

Disable

4-23

Transmit Code 39 Check Digit

Disable

4-23

Enable/Disable Code 39 Full ASCII

Enable

4-24

Enable

4-24

Enable/Disable Code I 2 of 5

Enable

4-24

Set I 2 of 5 Lengths

14 (length 1) 0 (length 2)

4-24

Modulo 10 Check Digit

Disable

4-26

ITF14/EAN13 Conversion

Disable

4-26

Enable/Disable Code D 2 of 5

Enable

4-27

Modulo 10 Check Digit

Disable

4-27

Code 128

Code 39

Code 93 Enable/Disable Code 93 I 2 of 5

D 2 of 5

4-4

Page 41

Programming the LS 1004

Table 4-1. Default Table (Continued) Parameter Set D 2 of 5 Lengths

Default

Page Number

12 (length 1) 0 (length 2)

4-27

Enable/Disable Codabar

Enable

4-29

CLSI Editing

Disable

4-29

NOTIS Editing

Disable

4-29

Transmit Code ID Character

Disable

4-30

Prefix

None

4-31

Suffix

CR/LF

4-31

Baud Rate

9600

4-34

Parity

Even

4-35

Data Format

7 Data Bits (with Parity)

4-36

Stop Bit Select

Two

4-36

Check Parity of Received Data

Enable

4-36

Hardware Handshaking

None

4-37

Software Handshaking

None

4-37

Intercharacter Delay

0msec

4-41

Codabar

Data Options

RS-232C

4-5

Page 42

LS 1004 Product Reference Guide

RS-232 Host Type Defaults Three RS-232C hosts are set up with their own parameter default settings (See Table 4-2.). Selecting the ICL, Fujitsu, or Nixdorf RS-232C terminal sets the defaults listed below. These defaults take precedence over standard defaults. So if you select Fujitsu RS-232C, then select the standard defaults, the Fujitsu defaults still take precedence. Table 4-2.Terminal-Specific RS-232C Defaults Parameter

Standard

ICL

FUJITSU

NIXDORF Mode A/ Mode B

Transmit Code ID

No

Yes

Yes

Yes

Data Transmission Format

Data as is

Data/Suffix

Data/Suffix

Data/Suffix

Suffix

CR/LF (7013)

CR (1013)

CR (1013)

CR (1013)

Baud Rate

9600

9600

9600

9600

Parity

None

Even

None

Odd

Hardware Handshaking

None

RTS/CTS Option 3

None

RTS/CTS Option 3

Software Handshaking

None

None

None

None

Serial Response Time-out

2 Sec.

9.9 Sec.

2 Sec.

9.9 Sec.

Stop Bit Select

One

One

One

One

ASCII Format

8-Bit

8-Bit

8-Bit

8-Bit

Beep On <BEL>

Disabled

Disabled

Disabled

Disabled

RTS Line State

Low

High

Low

*Low = No data to send

*In the Nixdorf Mode B, if CTS is Low, scanning is disabled. When CTS is High, the user can scan bar codes.

4-6

Page 43

Programming the LS 1004

RS-232C Code ID Characters Selecting the ICL, Fujitsu, or Nixdorf RS-232C terminal enables the transmission of Code ID Characters listed in Table 4-3. These Code ID Characters are not programmable and are separate from the Transmit Code ID feature. The Transmit Code ID feature should not be enabled for these terminals. Table 4-3.Terminal Specific Code ID Characters ICL

FUJITSU

NIXDORF

UPC-A

“A”

“A”

“A”

UPC-E

“E”

“E”

“C0”

EAN-8

“FF”

“FF”

“B”

EAN-13

“F”

“F”

“A”

Code 39

“C” <len>

None

“M”

Codabar

“N” <len>

None

“N”

Code 128

“L” <len>

None

“K”

I 2 of 5

“I” <len>

None

“I”

Code 93

None

None

“L”

D 2 of 5

“H” <len>

None

“H”

UCC/EAN 128

“L” <len>

None

“P”

Scanning Sequence A scanning sequence establishes a value for one parameter type. During a scanning sequence, bar codes are scanned to select a parameter. All bar codes necessary for programming the scanner are provided in Parameter Menus, beginning on page 4-9.

Scanning Sequence Example In this example, assume you want to program the scanner for all default settings except for two parameters, DECODE UPC ONLY and INTERCHARACTER DELAY. Since you want to keep the majority of the default settings, scan the SET ALL DEFAULTS bar code. The default for DECODE UPC ONLY is DISABLED, but in this example, you need it

4-7

Page 44

LS 1004 Product Reference Guide enabled. To do this, scan the DECODE UPC ONLY ENABLE bar code. You’ll hear hi/lo/hi/ low warble. The warble sound indicates that the scanner has been successfully programmed for the selected parameter. Other beeper indications are listed in Chapter 3. The default for INTERCHARACTER DELAY is 0 msec, but you need it set to 2 msec. To program the scanner for a 2msec intercharacter delay, scan the bar codes listed below. This sequence includes a two-digit entry; single-digit entries require a leading zero. You’ll hear... 1. Scan INTERCHARACTER DELAY

Short high tone

2. Scan 0

Short high tone

3. Scan 2

Hi/Lo/Hi/Lo warble

Errors While Scanning Don’t worry if you make an error during a scanning sequence. If you’re scanning a multi-step sequence, scanning CANCEL removes you from that sequence so that you can start again. Otherwise, simply scan the single correct bar code for the desired parameter.

4-8

Page 45

Programming the LS 1004

Parameter Menus Refer to the Default table in the front of this chapter for the default settings for each parameter type.

Set Parameter Defaults Scanning the SET ALL DEFAULTS bar code returns all parameters to the default values listed in the Default Table.

Set All Defaults

Host Interface Select Scan the bar code corresponding to your host type. You must select a host type when you first set up the scanner and whenever you change host type.

Set RS-232C Host

Set Synapse Host

4-9