Page 37
Chapter 4 Programming The LS 1004 Chapter Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3 RS-232 Host Type Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6 RS-232C Code ID Characters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7 Scanning Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7 Scanning Sequence Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7 Errors While Scanning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8 Parameter Descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9 Set Parameter Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9 Host Interface Select . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9 RS-232 Host Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10 Power On Beep Enable/Disable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11 Beeper after Decode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11 Beeper Tone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12 Beeper Volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12 Decode Attempt Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13 Operating Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14 Aggressive Scan Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14 Transmit “No Decode” Message. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15 Decode Redundancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15 Code Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15 UPC/EAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-17 Code 128 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-22 Code 39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-23 Code 93 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-24 Interleaved 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-24 Discrete 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-27
4-1
Page 38
LS 1004 Product Reference Guide
Codabar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-29 Data Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-30 RS-232C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-34
4-2
Page 39
Programming the LS 1004
Introduction This chapter provides information on how to program the LS 1004 scanner. Before programming the scanner, follow the instructions in Set-Up on page 1-3. The Table 4-1 illustrates the default values with which the scanner is shipped. If the default values suit your requirements, scan the SET ALL DEFAULTS barcode. This will set the scanner to the default parameters. Changing the scanner’s programmable parameters is accomplished by scanning the bar codes provided in this section. The following table lists the defaults for all parameters. If you wish to change any option, scan the appropriate bar code(s).
Table 4-1. Default Table Parameter
Default
Page Number
Set Default Parameter
All Defaults
4-9
Host Interface Select
RS-232C
4-9
Power On Beep
Disable
4-11
Beep after Decode
Enable
4-11
Beeper Tone
Middle
4-12
Beeper Volume
High Level
4-12
Decode Attempt Time
1 second
4-13
Operating Mode
Low Power
4-14
Aggressive Scan Mode
Disable
4-14
Transmit “No Decode” message
No Message
4-15
Decode Redundancy
Disable
4-15
Code Types
All
4-16
Enable/Disable UPC/EAN
Enable
4-17
Transmit UPC-A Check Digit
Enable
4-17
Transmit UPC-E Check Digit
Enable
4-17
UPC/EAN
4-3
Page 40
LS 1004 Product Reference Guide
Table 4-1. Default Table (Continued) Parameter
Default
Page Number
Decode UPC Only
Disable
4-17
Convert UPC-E to UPC-A
Disable
4-18
EAN Zero Extend
Disable
4-18
Decode UPC/EAN Supplemental
No Supplemental
4-19
UPC-E Preamble
System Character
4-20
UPC-A Preamble
System Character
4-20
UPC/EAN Security Level
Level 0
4-21
Enable/Disable Code 128
Enable
4-22
Send Code 128 Function Character
Disable
4-22
Enable/Disable Code 39
Enable
4-23
Code 39 modulo 43 check
Disable
4-23
Transmit Code 39 Check Digit
Disable
4-23
Enable/Disable Code 39 Full ASCII
Enable
4-24
Enable
4-24
Enable/Disable Code I 2 of 5
Enable
4-24
Set I 2 of 5 Lengths
14 (length 1) 0 (length 2)
4-24
Modulo 10 Check Digit
Disable
4-26
ITF14/EAN13 Conversion
Disable
4-26
Enable/Disable Code D 2 of 5
Enable
4-27
Modulo 10 Check Digit
Disable
4-27
Code 128
Code 39
Code 93 Enable/Disable Code 93 I 2 of 5
D 2 of 5
4-4
Page 41
Programming the LS 1004
Table 4-1. Default Table (Continued) Parameter Set D 2 of 5 Lengths
Default
Page Number
12 (length 1) 0 (length 2)
4-27
Enable/Disable Codabar
Enable
4-29
CLSI Editing
Disable
4-29
NOTIS Editing
Disable
4-29
Transmit Code ID Character
Disable
4-30
Prefix
None
4-31
Suffix
CR/LF
4-31
Baud Rate
9600
4-34
Parity
Even
4-35
Data Format
7 Data Bits (with Parity)
4-36
Stop Bit Select
Two
4-36
Check Parity of Received Data
Enable
4-36
Hardware Handshaking
None
4-37
Software Handshaking
None
4-37
Intercharacter Delay
0msec
4-41
Codabar
Data Options
RS-232C
4-5
Page 42
LS 1004 Product Reference Guide
RS-232 Host Type Defaults Three RS-232C hosts are set up with their own parameter default settings (See Table 4-2.). Selecting the ICL, Fujitsu, or Nixdorf RS-232C terminal sets the defaults listed below. These defaults take precedence over standard defaults. So if you select Fujitsu RS-232C, then select the standard defaults, the Fujitsu defaults still take precedence. Table 4-2.Terminal-Specific RS-232C Defaults Parameter
Standard
ICL
FUJITSU
NIXDORF Mode A/ Mode B
Transmit Code ID
No
Yes
Yes
Yes
Data Transmission Format
Data as is
Data/Suffix
Data/Suffix
Data/Suffix
Suffix
CR/LF (7013)
CR (1013)
CR (1013)
CR (1013)
Baud Rate
9600
9600
9600
9600
Parity
None
Even
None
Odd
Hardware Handshaking
None
RTS/CTS Option 3
None
RTS/CTS Option 3
Software Handshaking
None
None
None
None
Serial Response Time-out
2 Sec.
9.9 Sec.
2 Sec.
9.9 Sec.
Stop Bit Select
One
One
One
One
ASCII Format
8-Bit
8-Bit
8-Bit
8-Bit
Beep On <BEL>
Disabled
Disabled
Disabled
Disabled
RTS Line State
Low
High
Low
*Low = No data to send
*In the Nixdorf Mode B, if CTS is Low, scanning is disabled. When CTS is High, the user can scan bar codes.
4-6
Page 43
Programming the LS 1004
RS-232C Code ID Characters Selecting the ICL, Fujitsu, or Nixdorf RS-232C terminal enables the transmission of Code ID Characters listed in Table 4-3. These Code ID Characters are not programmable and are separate from the Transmit Code ID feature. The Transmit Code ID feature should not be enabled for these terminals. Table 4-3.Terminal Specific Code ID Characters ICL
FUJITSU
NIXDORF
UPC-A
“A”
“A”
“A”
UPC-E
“E”
“E”
“C0”
EAN-8
“FF”
“FF”
“B”
EAN-13
“F”
“F”
“A”
Code 39
“C” <len>
None
“M”
Codabar
“N” <len>
None
“N”
Code 128
“L” <len>
None
“K”
I 2 of 5
“I” <len>
None
“I”
Code 93
None
None
“L”
D 2 of 5
“H” <len>
None
“H”
UCC/EAN 128
“L” <len>
None
“P”
Scanning Sequence A scanning sequence establishes a value for one parameter type. During a scanning sequence, bar codes are scanned to select a parameter. All bar codes necessary for programming the scanner are provided in Parameter Menus, beginning on page 4-9.
Scanning Sequence Example In this example, assume you want to program the scanner for all default settings except for two parameters, DECODE UPC ONLY and INTERCHARACTER DELAY. Since you want to keep the majority of the default settings, scan the SET ALL DEFAULTS bar code. The default for DECODE UPC ONLY is DISABLED, but in this example, you need it
4-7
Page 44
LS 1004 Product Reference Guide enabled. To do this, scan the DECODE UPC ONLY ENABLE bar code. You’ll hear hi/lo/hi/ low warble. The warble sound indicates that the scanner has been successfully programmed for the selected parameter. Other beeper indications are listed in Chapter 3. The default for INTERCHARACTER DELAY is 0 msec, but you need it set to 2 msec. To program the scanner for a 2msec intercharacter delay, scan the bar codes listed below. This sequence includes a two-digit entry; single-digit entries require a leading zero. You’ll hear... 1. Scan INTERCHARACTER DELAY
Short high tone
2. Scan 0
Short high tone
3. Scan 2
Hi/Lo/Hi/Lo warble
Errors While Scanning Don’t worry if you make an error during a scanning sequence. If you’re scanning a multi-step sequence, scanning CANCEL removes you from that sequence so that you can start again. Otherwise, simply scan the single correct bar code for the desired parameter.
4-8
Page 45
Programming the LS 1004
Parameter Menus Refer to the Default table in the front of this chapter for the default settings for each parameter type.
Set Parameter Defaults Scanning the SET ALL DEFAULTS bar code returns all parameters to the default values listed in the Default Table.
Set All Defaults
Host Interface Select Scan the bar code corresponding to your host type. You must select a host type when you first set up the scanner and whenever you change host type.
Set RS-232C Host
Set Synapse Host
4-9