Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 6 of 13

LS 1004 Scanner Product Reference Guide: Chapter 3 Maintenance & Specifications

Pages 27 to 36 of 96, from LS 1004 Scanner Product Reference Guide

The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol LS-1004

Page 27

Chapter 3 Maintenance & Specifications Chapter Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 Maintaining the LS 1004 Scanner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 Battery Box Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 Required Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 What If... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5 LS 1004 Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6 LS 1004 Decode Zone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6

3-1

Page 28

LS 1004 Product Reference Guide

3-2

Page 29

Maintenance and Specifications

Introduction This chapter covers the suggested maintenance of the LS 1004 scanner, as well as the technical specifications, available accessories, pinouts, and beeper definitions.

Maintaining the LS 1004 Scanner Battery Box Operation When using the LS 1000 Series with a battery box, you can use either an alkaline battery (recommended), or a nickel-cadmium rechargeable battery. Low power is signalled by 4 short, high-tone beeps, coupled with scanning interruptions. If this occurs, change or recharge the battery as soon as possible. For battery box operation: 1. Insert a 9-volt battery into the battery box. 2. Plug the scanner’s 9-pin connector at the end of the coil cord into the end of the battery box. 3. An output cable from the battery box connects the LS 1004 to the host device. Connect one end of this cable to the battery box and the other to the appropriate port on the host device. Note: Not all applications require a power supply or battery box. The output cable depends on the wand being replaced.

Changing the Battery 1. Disconnect the battery box. 2. To open the battery box, push up on the flanges at one end of the pack. 3. Remove the old battery. 4. Insert the new or recharged 9-volt battery into the battery box. Match the positive (+) and negative (-) terminals on the battery with the corresponding terminals in the battery box.

3-3

Page 30

LS 1004 Product Reference Guide

Recharging a Nickel-Cadmium Battery !

Remove the battery from the battery box and place it in the recharging unit (not supplied by Symbol).

!

To recharge the battery, follow the instructions supplied with the recharging unit.

Maintenance Cleaning the exit window is the only maintenance required. !

Do not allow any abrasive material to touch the window.

!

Remove any dirt particles with a damp cloth.

!

Wipe the window using a damp cloth, and if necessary, a non-ammonia based detergent.

!

Do not spray water or other cleaning liquids directly into the window.

Accessories Required Accessories Required accessories are listed below. Optional accessories are available at extra cost. Table 3-1. LS 1004 Required Accessories Part Number

Description

ND1222

Synapse Adapter Cable

ND1223

One RS-232 Cable 9-pin female TxD pin 2, or

ND1224

One RS-232 Cable 25-pin male TxD pin 3, or

ND1225

One RS-232 Cable 25-pin TxD pin 3

70-17422-01

LS 1000 Series Quick Reference Guide

Optional Accessories Optional accessories include various stands and holders, which are supplied at extra cost. Additional units of standard accessories may also be purchased at extra cost.

3-4

Page 31

Maintenance and Specifications

What If... Nothing happens when you follow the operating instructions? You Should !

Check the system power; is there a battery in the battery box?

!

Be sure the scanner is programmed for the terminal in use.

!

Make sure the scanner is programmed to read the type of bar code you are scanning.

!

Check for loose cable connections.

!

Check the symbol to make sure it is not defaced.

!

Try scanning test symbols of the same code type.

!

Be sure you are within the proper scanning range.

Symbol is decoded, but not transmitted to the host terminal? You Should !

Be sure the proper host type is selected (See Chapter 4).

Scanned data is incorrectly displayed on the terminal? You Should !

Make sure the system is programmed for the correct keyboard type.

!

Make sure the CAPS LOCK key is off.

!

Be sure the proper host is selected.

!

Be sure editing options (e.g., UPC-E to UPC-A Conversion) are properly programmed.

If after performing these checks the symbol still does not scan, contact your distributor or call the Symbol Support Center. See page viii for the telephone number.

3-5

Page 32

LS 1004 Product Reference Guide

LS 1004 Technical Specifications LS 1004 Decode Zone

In.

Cm.

10

25.4

5

12.7

0

0

5

12.7

10

25.4

Scanner

5.0 mil 1.0

2.3

7.5 mil 5.0 0 13 mil

2.0

In. Cm.

0 0

9.0

20 mil minimum element width

5 12.7

10 25.4

15.0

15 38.1

Depth of Field in Inches/Centimeters Depth of field as a function of minimum element width.

Figure 3-1. LS 1004 Decode Zone

3-6

Page 33

Maintenance and Specifications

Table 3-2.Technical Specifications Item Power Requirements* RS-232C/Synapse Low Power

Description 4.75 to 14.5 VDC (max) 100mA @ 5VDC typical 4.75 to 14 VDC (max) 200 mA @ 5V typical

Decode Capability

The LS 1004 can be programmed to decode the following code types: UPC/EAN, Code 39, Code 39 Full ASCII, Code 93, Codabar, Interleaved 2 of 5, Code 128, EAN 128, and Discrete 2 of 5. Set code length(s) for any linear code type. The LS 1004 can auto-discriminate between all of the above code types except for Code 39 and Code 39 Full ASCII.

Beeper Operation

User-selectable: Enabled, Disabled, Volume, Tone

Scan Repetition Rate

36 (± 3) scans/sec (bidirectional)

Skew Tolerance

± 65° from normal

Pitch

± 60° from normal

Decode Depth of Field

See Decode Zone

Print Contrast Minimum

25% absolute dark/light differential, measured at 670 nm.

Ambient Light Immunity Artificial Lighting Sunlight

450 ft. candles 8000 ft. candles

4844 lux 86112 lux

3-7

Page 34

LS 1004 Product Reference Guide

Table 3-2.Technical Specifications (Continued) Item

Description

Operating Temperature

32° to 104°F0° to 40°C

Storage Temperature

-40° to 140°F-40° to 60°C

Humidity

5% to 95% (non-condensing)

Durability

4-ft. drop to concrete1.2 m

Dimensions Height Length Width

4.8 in.122 mm 3.7 in.93 mm 2.4 in.60 mm

Laser Classifications

CDRH Class II IEC 825 Class 2

Start-Up Time

<50 msec from scan enable

Data Acquisition Time

<110 msec from scan enable

Minimum Element Width

0.005 in0.127 mm

Maximum Element Width

0.020 in5.08 mm

*For direct host power connection, make sure the host terminal supplies sufficient power for the specified operation. Symbol is not responsible for damage to host equipment or system mis-operation due to an insufficient power condition.

Table 3-3. Pinouts Pin

3-8

LS 1004

Function

1

Data

Data Line (for synapse)

2

VBAT

Power Supply

3

GND

Ground

4

RTS

Request to Send (for RS-232C)

5

RXD*

Receive Data Input (for RS-232C)

Page 35

Maintenance and Specifications

Table 3-3. Pinouts (Continued) Pin

LS 1004

Function

6

N.C.

Non-Connected (for RS-232C)

7

DTR

Data Terminal Ready (for RS-232C)

8

TXD*

Transmit Data Output (for RS232C)

9

CTS

Clear to Send (for RS232C)

10

Clock

Clock Line (for Synapse)

* active low Table 3-4. Beeper Indications Standard Use Beeper Sequence

Indication

1 Beep - short high tone

A bar code symbol was decoded (if decode beeper is enabled).

4 Beeps - long low tone

A transmission error has been detected in a scanned symbol. The last data scanned was lost. Scan the last data again.

4 Beeps - short high tone

Low power indication; no further scanning is possible. Change or recharge battery.

3 Beeps - short high tone

Power-up (continuous power mode only)

Parameter Menu Scanning 1 Beep - short high tone

Appropriate menu within the scanning sequence has been read

1 Beep - warble sound

Parameter value entered successfully

2 Beeps - long low tone

Parameter not entered, or incorrect sequence performed. Scan CANCEL and restart the scanning sequence.

3-9

Page 36

LS 1004 Product Reference Guide

3-10