Page 24
Series 3800 Product Reference Guide
3865 and 3866 Cradles The CRD 3865 can be wall-mounted on a wall bracket for convenience.
Wall Mounting the 3865 To wall-mount the 3865: 1. Mark where you want the cradle positioned on the wall. 2. Using a fastener appropriate to the wall construction, insert and secure the fastener (A in Figure 2-1). Let the head protrude slightly.
A
B
B
Figure 2-1. Wall Mounting the 3865 3. 4. 5. 6.
2-2
Slide the bracket down over the head of the fastener. Remove the black tape covers from the cradle screw holds. Slide the cradle into the bracket. Secure the cradle to the bracket (B in Figure 2-1) using two #10 metal screws.
Page 25
Hardware Setup
Table Mounting the 3866 Note: Installing the suction cup feet is not mandatory but helps keep the cradle in place. 1. On the bottom of the cradle, thread each of the four suction cup feet into the screw holes. 2. Wet the base of each suction cup and secure the cradle to a smooth tabletop by pushing firmly down on the cradle (Figure 2-2).
Figure 2-2. Installing Suction Cups on the CRD 3866
2-3
Page 26
Series 3800 Product Reference Guide
Connecting Power Note: The process for connecting power is the same for both cradles. 1. Connect the power supply cord’s round plug to the power connector on the left side of the cradle. 2. Connect the power supply’s AC plug to a standard electrical outlet. The green and red indicators light for 3 seconds, blink for 3 seconds, then go out.
3865
3866
Figure 2-3. Connecting the CRD 3865 and CRD 3866 to a Power Source
2-4
Page 27
Hardware Setup
Connecting for Data Communications To connect the CRD 3865 or CRD 3866: Note: Be sure to unplug the cradle’s power supply before connecting the serial cables. 1. Turn off the PC. 2. Plug the RS-232 serial cable’s DB-25 connector in the cradle’s communication port (Figure 2-4). 3. Connect the cable’s other connector to the host computer’s serial (COMM) port.
RS-232 Serial Cable RS-232 Serial Cable
Charging LED
COMM LED Power Supply
Power Supply
CRD 3865
Charging LED
COMM LED
CRD 3866
Figure 2-4. Connecting the 3865 and 3866 Cradles for Communications with Computer, Printer, or Modem
2-5