The text of a manual · part 23 of 25
Series 3800 Product Reference Guide, pages 123 to 130
Pages 123 to 130 of 138: STAT24; DIAG24
The original document is the PDF (1.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol LRT-3800 and Symbol LRT-3824
Page 123
Spectrum24 Network and Flash Disk Utilities
STAT24 STAT24 is a Terminate and Stay Resident (TSR) program used to provide the status of the radio connection. It can also be used to check for RF association and alternate actions in batch files depending on the association status. This utility is used mainly to check for associations with an AP when RF difficulties are experienced. Some applications may unload the STAT24 TSR if they cannot afford the program execution space it occupies. STAT24 uses the text message file MSG.MSG, read from the same drive and directory as the executable, STAT24.COM. Corrupted screens are an indication that the message file was not found. STAT24 is loaded during standard start-up procedures. To view the STAT24 pop-up screen (Figure E-11), press the hot-key sequence <CTRL+FUNC+1>.
Description In the standard terminal initialization procedure, when the system software is loaded and connection to the RF network is attempted, STAT24 is used in two different ways: ! !
the program loops until the terminal either associates with an Access Point (AP) or times out. By default the default time-out is 10 seconds. the program installs itself as a TSR and provides a hot-key sequence that pops up a display of the current radio connection status and radio quality for the previous minute (refer to Figure E-11). When in this pop-up mode, the program returns to the application screen if any key is pressed. Note: This program can be unloaded due to application memory constraints, if required. RF STATUS v1.xx Term:00a0f8000232æ fw:V3.21 970819 AP:00a0f8f0223d Net Id:15a AP Id:13 AP Cnt:1 Rf Quality: Fair 12,23,8,14
Line 1
Line 8
Figure E-11. STAT24 Screen E-11
Page 124
Series 3800 Product Reference Guide
The fields in Figure E-11 are interpreted as follows:
E-12
Line 1
Title and version number of STAT24.
Line 2
The terminal’s IEEE address.
Line 3
The version and date of the adapter firmware.
Line 4
The IEEE (MAC) address of the Access Point the terminal is associated with.
Line 5
The Net Id for the network.
Line 6
The AP identifier of the AP the terminal is associated with.
Line 7
A qualitative statement about the radio transmissions over the previous minute. The analysis is simplistic and takes no account of how much other radio traffic there may be. The judgements are essentially for a terminal in a quiet environment: what is poor for a single terminal may be good in a heavy traffic environment. The range of statements is “Good”, “Fair”, and “Poor”.
Line 8
Four values used to derive the quality judgement provided in line 7. In order, they represent for the last full minute: " total packets transmitted " total packets received " percent error packets transmitted " percent error packets received
Page 125
Spectrum24 Network and Flash Disk Utilities
DIAG24 DIAG24 is intended for use in two situations: ! !
As a connectivity tool, using a ping that is not re-tried on transmission errors. This test is intrusive as pings are sent as fast as possible. As a diagnostic tool for potential radio problems. It can eliminate or confirm that the traffic problems are in the radio portion of the network. The round-trip time reported during the test indicates the portion of the transaction response time that is attributable to the radio network.
This program uses the text message file MSG.MSG which is read from the same drive and directory as the executable (DIAG24.EXE). Corrupted screens are an indication that the message file was not found.
Syntax DIAG24
Description To run DIAG24 on a 3840: 1. At a DOS prompt on the terminal, type: DIAG24 and press <ENTER>. The menu shown in Figure E-12 is presented. DIAG24 ver 1.xx 1. AP Ping Test 2. Field Diagnostics Select[1-2 or ‘Q’]:
Figure E-12. DIAG24 Screen
E-13
Page 126
Series 3800 Product Reference Guide
Note: Press Q in any subsequent menu to return to the DIAG24 menu or to exit DIAG24 from this menu. 2. Press either (1) AP Ping Test or (2) Field Diagnostics. Press Q to quit. Whichever mode was selected from the DIAG24 menu, the subsequent set-up menus that follow are identical, except for the title line which indicates the selected test mode: AP PING TEST for selection 1; FIELD DIAGNOSTICS for selection 2 (see Figure E-13). <Test Mode> 1. Roaming Enabled 2. bb--eeeeeeeeeeee 3. bb--eeeeeeeeeeee ::: ::: n. bb--eeeeeeeeeeee Select [1-n or ‘Q’]:
Figure E-13. Test Mode Screen 3. Select the roaming mode. For each AP listed by line number: bb represents the AP identifier (or BSS identifier)
eeeeeeeeeeee is the 48-bit MAC address of the AP in hexadecimal notation.
"
If you select Roaming Enabled, the terminal pings the associated AP and roams as required between APs. " If you select a specific AP in the list, the test is conducted solely with that AP. " If more APs are in range than can fit on one screen, the last selection is “More”. Select this to present more APs for selection.
E-14
Page 127
Spectrum24 Network and Flash Disk Utilities
4. To exit the screen select Q or press <CLEAR>. <Test Mode> MESSAGE SIZE 1. 100 bytes 2. 256 bytes 3. 512 bytes Select[1-3 or ‘Q’]:
Figure E-14. Ping Message Size 5. Select the ping message size in the Message Size screen shown in Figure E-14. Press the corresponding number to make the selection and advance to the next screen. Press Q or <CLEAR> to return to the main menu. <Test Mode> NUMBER OF PINGS 1. 100 pings 2. 500 pings 3. 1000 pings 4. Non-stop Select 1-4 or ‘Q’]
Figure E-15. Number Of Pings Screen 6. Select a counter for the number of test iterations in the Number of Pings screen shown in Figure E-15. Press the corresponding number to make the selection and advance to the next screen. Press Q or <CLEAR> to return to the main menu. <Test Mode> BEEP MODE 1. Beep on error 2. Silent 4. Non-stop Select 1-2 or ‘Q’]
Figure E-16. Beep Mode Screen E-15
Page 128
Series 3800 Product Reference Guide
7. Select whether to sound a beep if an error is encountered in the Beep Mode screen shown in Figure E-16. Press the corresponding number to make the selection and advance to the test screens. Press Q or <CLEAR> to return to the main menu.
Ping Tests During an AP ping test, the screen shown in Figure E-17 is displayed and continuously updated. AP PING TEST A Cnt Err AP RS 56 2 04 36 57 2 04 36 58 3 04 36 TMO 59 3 04 36 55 2 04 36 Press ‘Q’ to Quit
Figure E-17. AP Ping Test Results Each ping results in a new line being displayed, showing the cumulative ping count, error count, AP identifier of the AP the terminal is associated with, and the RSSI value of the terminal reception. If there was an error, an indicator appears at the right-hand end of the line (see line 5 in Figure E-17). The report wraps around so that, at any given time, the last five message reports are visible. The ‘A’ at the left end of line 2 in Figure E-17 indicates that the terminal is associated with an AP. A ‘U’ indicates that the terminal is not associated.
E-16
Page 129
Spectrum24 Network and Flash Disk Utilities
When the ping test is running in non-stop mode, if either of the count fields overflows, the first detail line is pre-empted to show the most significant digits of the count, prefixed with an asterisk (Figure E-18). AP PING TEST A Cnt Err AP RS * 6 * 2 04 36 57 2 04 36 58 3 04 36 TMO 59 3 04 36 55 2 04 36 Press ‘Q’ to Quit
Figure E-18. AP PingTest Results (Non-Stop Mode) In Figure E-18, the first detail line reads “*6*2...” showing that the real values for the counters in the second and subsequent detail lines are 600, 057, and 2,002. Press <Q> or <CLEAR> to terminate the test and return to the DIAG24 menu. AP PING TEST Total secs = 7.4 Pings = 100 Packet size = 100 Retries = 0 Timeouts = 4 [R}epeat or [Q]uit
Figure E-19. AP PingTest Summary When the ping test is stopped, the summary screen (Figure E-19) is displayed, showing the elapsed time of the test, total pings transmitted, packet size used, retry count, and number of timeouts. To repeat the test with the same parameters, press <R>. Press <Q> or <CLEAR> to terminate the test and return to the DIAG24 menu.
E-17
Page 130
Series 3800 Product Reference Guide
Field Diagnostics During a field diagnostic test, the screen shown in Figure E-20 is displayed and continuously updated. FIELD DIAGNOSTICS A Cnt Err Rty ms AP 56 2 0 165 52 57 2 0 55 52 58 3 1 TMO 52 59 3 0 220 52 55 2 0 55 52 Press ‘Q’ to Quit
Figure E-20. Field Diagnostics (Screen 1) Each ping results in a new line being displayed, showing the cumulative ping count, error count, retry count for this message, round-trip time in milliseconds for this message or indication of error type if there was an error, and the AP identifier of the AP that responded to the message. When the test stops, a summary screen is displayed (Figure E-21). FIELD DIAGNOSTICS Total secs = 8.2 Pings = 100 Packet size = 512 Retries = 6 Timeouts = 4 [R]epeat or [Q]uit
Figure E-21. Field Diagnostics Summary Screen Press <Q> or <CLEAR> to terminate the test and return to the DIAG24 menu.
E-18