Page 92

Series 3800 Product Reference Guide

Error Messages If ERR3000 is loaded in the system configuration, the terminal displays the following messages to indicate error conditions that affect system performance. A message is usually accompanied by one or more beeps, after which the system returns to its previous status. The application can change the actual wording of the messages or disable messages. The messages listed in Table 7-1 are representative. Refer to the Series 3000 Application Programmer's Guide or your application guide for additional information. Table 7-1. Error Messages Message

Explanation

Double Key Error

Two or more keys were pressed at the same time.

Low Battery

The battery pack should be recharged or replaced as soon as possible.

Replace Cells

Replace or recharge the battery pack immediately. This message is programmable, so it may be worded differently. See your application guide. After this message is displayed, the terminal shuts itself off.

Power Fault

The last terminal power off was caused by a terminal power failure. Possible causes of a power fault include: • the battery pack is removed with the terminal on. • the terminal is dropped. • the batteries lose power suddenly. • the terminal displays a low battery power error message, and you attempt to power the terminal on without recharging or replacing the batteries.

7-2

Page 93

Error Recovery and Troubleshooting

Troubleshooting Guide Table 7-2 lists some minor problems, causes, and actions to take. If you cannot resolve the problem after checking this list, call the Symbol Support Center for assistance. Table 7-2. Troubleshooting the 3800 Symptom

Possible Cause

Action

Display is blank.

Battery pack is dead or missing.

Replace or recharge battery pack.

Terminal does not respond when keys are pressed.

Application program was not Repeat downloading. successfully downloaded.

Time and date are incorrect.

Real-time clock has malfunctioned or needs setting.

Set time and date. See your application guide.

Startup Failure Problems are most frequently start-up failures. If cold booting the terminal does not start the application successfully, either the application, the system software, or the system is malfunctioning. If you can boot the system to Command Mode, try the following: !

!

Use Program Loader to download a new version of the software to NVM. This procedure is described in Chapter 3, Batch and Spectrum One Terminal Setup. After downloading new software, warm boot the terminal as described in Chapter 5, Operating the Series 3800. Use Self Test to check whether system hardware is operational. The Self Test procedure is described later in this chapter.

Boot Failure Messages During a cold boot, the system briefly displays a status line for each driver as it loads, in the format 0:Driver

#.##

The line shows a status value, usually 0, followed by the name and version number of the driver. If the system halts at one of these lines and displays a status value other than 0, the displayed driver did not load properly.

7-3

Page 94

Series 3800 Product Reference Guide

If such a failure occurs, cold boot the terminal again. If this does not solve the problem, call Symbol Customer Support. More troubleshooting information is found in the documentation listed in Related Publications.

Spectrum24 Terminal (3840) Initialization Failures The Command Mode troubleshooting procedures used by 3800 batch or Spectrum One terminals are not available to terminals operating in a Spectrum24 network environment. Typical initialization and operating problems and solutions for Spectrum24 terminals are listed in Table 7-3. A diagnostic tool, DIAG24, is provided with the 3840 for testing connectivity and diagnosing potential radio problems. Refer to Appendix E, Spectrum24 Network and Flash Disk Utilities, for more information. Table 7-3. Troubleshooting Spectrum24 Terminal s Problem

7-4

Explanation/Action

Boot process fails

Terminal is out of the AP’s range. If you move the terminal during the boot process, terminal may be out of range of the AP and unable to complete the process. Do not move terminal while booting. OR Boot server doesn’t exist. Check to ensure boot server is operating. OR Boot server not configured for this terminal. Check with network administrator.

File transfer process failed.

Terminal is out of the AP’s range. If you move the terminal during download, terminal may be out of range of the AP and unable to complete the download. Move back in range and continue the download process. OR File transfer host is not set up with the boot file information or host is not available. Verify that all required files are available on the file transfer host. OR Segments missing from the file transfer directory. Check directory for all required files.

Page 95

Error Recovery and Troubleshooting

Table 7-3.Troubleshooting Spectrum24 Terminals (Continued) Problem

Explanation/Action

Low battery message.

Place the terminal in a cradle and recharge battery. OR Connect terminal to charger and recharge battery. OR Power terminal off and replace battery.

Battery is dead.

Battery not replaced after receiving low battery message or terminal left on for more than 24 hours. Replace the battery. Note: Terminal loses software when power is lost. To reload software, cold boot terminal and enter Net Id manually. Associate with AP and reacquire boot files as described in Initiate Network Connection.

Terminal disassociated from Access Point.

Application does not respond to interactive operations. Applications using internal batch mode continue to function until required to transmit via radio, then fail to work. No message displayed.

7-5