The text of a manual · part 10 of 25
Series 3800 Product Reference Guide: Updating System Software on Flash Disk
Pages 56 to 63 of 138, from Series 3800 Product Reference Guide
The original document is the PDF (1.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol LRT-3800 and Symbol LRT-3824
Page 56
Series 3800 Product Reference Guide
Updating System Software on Flash Disk Updating the LWP hex image means loading the new system files on the flash disk using the SENDHEX utility on a PC. It is possible to perform this update on multiple terminals in a cradle at one time, with each terminal running Program Loader from Command Mode. Note:
The Series 384X is shipped with the LWP hex file installed. Use this procedure ONLY: • to load a new version of LWP greater than 3.03 • if you experience serious difficulties • if you are so directed by Symbol’s Technical Support staff.
Option: Using _L.BAT to Update System Software If the Series 384X terminal contains a LWP hex file of version 3.03, you can follow the instructions for installing application software on the flash disk using _L.BAT through step 6, when the terminal is reinitialized. Proceed to step 6 of this procedure at that point. Note: Be sure, when entering the SENDHEX command on the PC, to issue the command from the directory where the hex file (LWP.HEX) is stored.
Initiate Host Communications on the PC To update the system software: 1. Power on the host computer. 2. On the PC, change to the directory where the system hex file (LWP.HEX) is stored and type the following command at a DOS prompt: SENDHEX LWP 384 [1|2] <ENTER>
4-16
Page 57
Spectrum24 Terminal Setup where: SENDHEX is the command.
LWP is the hex file being loaded. LWP.HEX is the hex file specifically for the system files. There may be other hex files which load other software, such as applications, to the flash disk.
384 is the baud rate (38,400 bps).
[1|2] sets the host’s communication port the cradle is connected to.
The following message is displayed: Press <ENTER> when remote is ready. ESC to abort...
3. Do NOT press <ENTER> yet. Set up the terminal as described in Initiate Terminal Communications.
Initiate Terminal Communications 1. Power off the Series 384X and place it in the cradle. 2. Boot the 384X to Command Mode. For the 35-key 384X: "
Press and hold <BKSP + Shift>. " Press and release PWR. " Release <BKSP + Shift>. For the 46-key 384X: "
Press and hold <A + B + D>. " Press and release PWR. " Release <A + B + D>. The terminal displays the function selector screen: COMMAND MODE Select function Self Test
4-17
Page 58
Series 3800 Product Reference Guide
3. Scroll through the Command Mode options using # or $ until “Program loader” is displayed. Press <ENTER>. 4. The 384X displays: Program loader WARNING: EEPROM WILL BE ERASED CONTINUE? <ENT>
Note: To cancel this operation, press <CLEAR>. 5. Press <ENTER> to erase the EEPROM. Wait while the EEPROM is erased. When complete, the program prompts for the communications parameters. 6. Set the parameters to 38,400 bps, 7 data bits, odd parity, and no flow control. Press <ENTER>.
Start Communications 1. The 384X displays: Comm Parameters Start? <ENT>
2. Press <ENTER> on the 384X. 3. The 384X displays: Comm Parameters Receiving: XXXX
If the host is not ready or if the cable is not connected properly between the host PC and the cradle, the 384X displays: Awaiting DSR
4-18
Page 59
Spectrum24 Terminal Setup
4. Press <ENTER> on the host PC to start the download. The 384X displays: Program loader Status XXXX
5. When the transmission is complete, the 384X displays: Program loader Status 0000
A status of 0000 (all zeroes) indicates a successful transfer. If the status is other than 0000, check the cable connections between the host PC and the cradle and repeat the process. If the problem persists, contact the Symbol Support Center for assistance. 6. When the download is complete, the Series 384X displays the following query: LWP.HEX Ver X.XX Loading system files 1. Reformat flash 2. Use flash as-is Select [1,2]:
Caution Reformatting the flash removes all system files and applications stored on the flash disk. Select 1, Reformat flash, ONLY if you have problems with the Series 384X’s operation. Select 2, Use flash as-is, to update the flash while retaining the existing contents. 7. If you select 1, the 384X displays the message: Are You sure Y or N
8. Press Y to continue with the reformat or N to cancel and press <ENTER>. The Series 384X finishes reformatting (if requested), copies the files to the flash disk, and executes them.
4-19
Page 60
Series 3800 Product Reference Guide
Compatibility Issues When Updating While the order in which software packages are loaded is not important, we recommend loading the system files, LWP.HEX, first, before loading any application files. You don’t have to reload existing applications that conformed to previous standards for flash disk applications. Loading just the system files allows the old applications to run with updated system software. Note: Some configuration changes may be required.
Complications: Naming Applications In versions of LWP.HEX for flash disk terminals prior to version 3.03, parameters were defined in NET.CFG to specify the applications that would run on the terminal. If only one application was used and no applications were defined in NET.CFG, the system gave the application the default name, APP. This can cause problems if you plan to add more applications to terminals using version 3.03 HEX files. With LWP.HEX 3.03, the application entries in NET.CFG are not longer required. The system now decides which applications are installed on the terminal by scanning the flash disk’s directories and files. If you had an original application with the default name APP, it will show up in the application selection menu as APP. If you updated that old application (e.g., created a version 3.03 HEX file of the application), the application selection menu will contain both versions, one called APP and one by the “real” name (e.g., STEP). Because of this potential problem, if ALL the software on the flash disk is being replaced in the update, we recommend reformatting the flash disk using FLSHFMT. Reformatting deletes ALL the files on the flash disk and eliminates this duplication. Note: DO NOT run the FLSHFMT utility unless all the HEX files, including LWP.HEX, are available to recreate the flash disk file system.
Complications: System Parameters In flash disk terminals with a LWP.HEX version prior to 3.03, some system parameters were changeable only by editing NET.CFG (e.g., power management mode, boot mode, and diversity). These parameters were not saved in the radio flash.
4-20
Page 61
Spectrum24 Terminal Setup
When the LWP.HEX is updated to 3.03, these values revert to the defaults. Be sure to check them after LWP.HEX is installed. In particular, verify whether a BOOTP or DHCP server is being used to allocate IP addresses. The default boot mode in version 3.03 is manual entry of IP addresses. The terminal enters the configurator during the first terminal initialization after the LWP.HEX upgrade, allowing you to check the settings.
Multiple Applications on the Same Terminal The system files (from LWP.HEX) fill over 200 KB of the flash disk’s 1 MB. Current standard applications such as STEP or TN clients require between 100 KB and 150 KB of flash disk. This leaves ample space for installing more than one application on a single Series 384X. Terminals have been configured to run as many as four applications, with a maximum of five applications allowed. Individual applications may require special terminal configurations that can only be set at boot time, such as RAM disk size. The TN clients require configuring a minimum-size RAM disk (<100 KB) because their limiting resource is program execution space. STEP, on the other hand, uses the RAM disk to hold forms. Some STEP application implementations use forms extensively and require a larger RAM disk (>100 KB). The application loaded last defines the size of the RAM Disk for all applications on the flash disk. Note: The system files contained in theLWP.HEX have the RAM disk defined as 80 KB. It is possible with multiple applications to have applications coexisting on the terminal with conflicting memory requirements. If this occurs, work out a compromise value that both applications can work with before loading the files. If multiple applications are installed on the Series 384X, a menu is presented during the initialization process where you select the application to run for this session. Switching between applications requires re-initializing the terminal and selecting an alternative application when prompted. On warm boots, the terminal re-initializes and reenters the same application that was selected before the re-initialization. On cold boots, if there are multiple applications available, an application selection menu is presented.
4-21
Page 62
Series 3800 Product Reference Guide
4-22
Page 63
Chapter 5 Operating the Series 3800 Overview This chapter describes how to operate a Series 3800 terminal including: ! ! ! ! ! !
Powering the 3800 on and off Booting the 3800 Adjusting the display Entering data using the keyboard Entering data using the scanner Communicating with a PC, printer, or modem.
5-1