FMT1000 Series Programmer's Guide: Chapter 2 I/O System Programming, pages 131 to 134

Pages 131 to 134 of 142, from FMT1000 Series Programmer's Guide

The original document is the PDF (965 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol FMT-1020

Page 131

I/O System Programming

ROB – Return State of Battery Sense Format ROB

Summary Returns an integer that indicates on-battery operation.

Returns Battery state, integer 0 or 1 0=Voltage input is 12VDC supply 1=Voltage input is battery pack

Description This command is used to read the battery sense input. When the power input is lost, and the battery pack takes over, this input will switch from 0 to 1.

Example rem echo rem

Read battery sense bit. ROB > COM2 The return string will be '0' or '1'.

2-111

Page 132

FMT1000 Series Programmer’s Guide

SBE, RBE – Set and Return Battery Sense Enable Format SBE 0 | 1

0=disable 1=enable

Summary Enables or disables automatic battery power sense.

Returns Battery sense enable, 0 or 1.

Description This command enables the automatic battery power sense feature. This feature senses the switchover to battery power within 20 seconds of primary power loss. A string is sent to the CPU via the internal path to alert the application of the condition. Also see the SBS command, page 2-113.

Example rem echo rem echo rem rem rem

2-112

Enable battery sense. SBE1 > COM2 Set switched to battery string. SBS Power_Failed! > COM2 If primary power is lost and the battery pack is installed, the string 'Power_Failed!' will be sent to the CPU.

Page 133

I/O System Programming

SBS, RBS – Set and Return Switched to Battery String Format SBS<string>

Maximum string length: 16 characters

Summary Set switched to battery string.

Returns Switched to battery string 0-16 characters.

Description This command sets the switched to battery string used by the automatic battery power sense feature. This feature senses the switchover to battery power within 20 seconds of primary power loss. The string is sent to the CPU via the internal path to alert the application of the condition. Also see SBE command, page 2-112.

Example rem echo rem echo rem rem rem

Enable battery sense. SBE1 > COM2 Set switched to battery string. SBS Power_Failed! > COM2 If primary power is lost and the battery pack is installed, the string 'Power_Failed!' will be sent to the CPU.

2-113

Page 134

FMT1000 Series Programmer’s Guide

2-114