Page 121
I/O System Programming
SnD, SnU – Set User Defined Key Up and Down Scan Codes RnD, RnU – Return User Defined Key Up and Down Scan Codes Note: n = 1, 2, 3, or 4
Format SnD <string> SnU <string> RnD RnU
Summary Sets the scan codes sent in response to pressing and releasing the user-defined keys or UDKs. This setting is preserved in EEPROM.
Returns Description These functions allow the user to define keys to do any special key sequence that cannot be generated by the keyboard. Due to space limitations, it is not possible to implement the full 83-key keyboard on FMT1000 Series computers; missing sequences that are required for an application can be generated using UDKs. Note: Because keyboard scan codes are used, virtually any keyboard action can be duplicated. Each UDK can hold 8 up and 8 down scan codes. Scan codes are input as 2 hex digits, preceded by a backslash (\).
2-101
Page 122
FMT1000 Series Programmer’s Guide
Example (SnD and SnU): To implement <control><break> on UDK1, the following commands would be used: S1D\1D\EO\46\EO\C6 Set User Defined Key 1 Down (UDK1 DOWN)
S1U\9D Set User Defined Key 1 Up (UDK1 UP)
Implementing hardware reset is a special case. To define a UDK to be hardware reset use: S1D\FF\FF\FF\FF Set User Defined Key 1 Down (UDK1 DOWN)
2-102
Page 123
I/O System Programming
RVR – Return Firmware Version Format RVR
Summary Returns the current firmware revision level of the I/O coprocessor
Returns A string of the format I/O Coprocessor v XX.YY. Description Returns information pertaining to the revision levels of the firmware in the I/O coprocessor board. XX denotes the major version number, and YY designates the revision level within the version.
Example At the DOS prompt, type: C:\>echo rvr > COM2
The following will be returned: C:\>I/O Coprocessor v 01.01
2-103
Page 124
FMT1000 Series Programmer’s Guide
SFD – Reset to Factory Defaults Format SFD
Summary Resets I/O configuration parameters to their factory defaults.
Returns Single beep if successful.
Description This command resets most configuration parameters to factory defaults. If a parameter does not have a factory default, it is not reset. These parameters are noted in this manual. This command does not reset the keyboard type, as set by the SKT command, or the viewing angle.
Example rem echo
2-104
Reset to factory defaults. SFD > COM2
Page 125
I/O System Programming
SEE – Write Setup to EEPROM Format SEE
Summary Writes the I/O configuration data to the EEPROM.
Returns Single beep if successful.
Description Once changes have been made and verified in the I/O processor configuration, they can be written to the EEPROM so that the FMT1000 Series computer will remember them every time it is powered up.
Example rem echo
Write configuration data to EEPROM. SEE > COM2
2-105
Page 126
FMT1000 Series Programmer’s Guide
RER – Return Error Code Format RER
Summary Returns an error code relating to the last command.
Returns Error code, integer 0-5 0=no error 1=command error 2=parameter error 3=timeout error 4=request was canceled 5=busy
Description This command returns an error code relating to the last command executed. It allows sync with I/O processing. RER may be performed after each command.
2-106
Page 127
I/O System Programming
Return Code
Error/Status
Description
1
(command error) indicates that the last command mnemonic was incorrect or inappropriately sequenced.
2
(parameter error) indicates that the parameter following the command was incorrect or inappropriate. This error can also occur if a required parameter is missing from a command.
3
(timeout error)
occurs if the timeout value is exceeded; see the SOO set output timeout or SIO set input commands.
4
(request canceled)
indicates that the SOC output cancel or SIC input cancel command was properly received and executed by the I/O processor.
5
(busy)
used when the auxiliary I/O device has not completed a transfer but has also not timed out.
2-107
Page 128
FMT1000 Series Programmer’s Guide
SBP – Set Beeper Tones Format SBP <0-5>
0=high pitch 1=high, low pitches 2=high, high pitches 3=high, low, high pitches 4=high, high, high pitches 5=tick sound
Summary Allows different beep tones to be generated by the internal beeper.
Returns N/A
Description This command allows the user to easily generate a variety of beep patterns for application specific use. One beep pattern sounds each time the command is executed.
Example rem echo
2-108
Cause beep: high, low, high pitches. SBP3 > COM2
Page 129
I/O System Programming
SSS, RSS – Set and Return Startup String Format SSS <string>
Max length: 16
Summary Sets a string that may be recalled upon demand to execute a terminal specific command on startup. This setting is preserved in EEPROM.
Returns Startup message, string no more than 16 characters.
Description This string is provided to allow a simple method for each FMT1000 Series computer to take a custom action on booting. In general the technique is as follows: 1. For each different power on action, write a batch file or other program to invoke it, and store it in the logon directory on the network. 2. On power up, include commands that a. make the internal response path the keyboard b. recall the startup string. 3. Store the name of the batch file (or other program) as the startup string (remember to include a carriage return or set autoenter mode appropriately). On boot, the startup string is recalled and executed as though typed, and the user-written program or batch file executes. The factory default is null (no message).
Example rem echo
Set startup string to 'INIT'. SSSINIT > COM2
2-109
Page 130
FMT1000 Series Programmer’s Guide
RES – Echo String Via Current Internal Response Path Format RES <string> Max length: 80
Summary Echoes the string to current internal response path.
Returns <string>
Description Used for diagnostic purposes, to check out coprocessor communications.
Example echo rem rem
2-110
RES This is a test. > COM2 'This is a test.' will be sent to the CPU via the internal path.