The text of a manual · part 9 of 55
Symbol DS6708 Digital Scanner Product Reference Guide: User Preferences & Miscellaneous Digital Scanner Options, pages 47 to 54
Pages 47 to 54 of 458, from Symbol DS6708 Digital Scanner Product Reference Guide
The original document is the PDF (11 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol DS-6708
Page 47
Chapter 4 User Preferences & Miscellaneous Digital Scanner Options Introduction You can program the digital scanner to perform various functions, or activate different features. This chapter describes each user preference feature and provides programming bar codes for selecting these features. The digital scanner ships with the settings shown in Table 4-1 on page 4-2 (also see Appendix A, Standard Default Parameters for all host device and miscellaneous defaults). If the default values suit requirements, programming is not necessary. To set feature values, scan a single bar code or a short bar code sequence. The settings are stored in non-volatile memory and are preserved even when the digital scanner is powered down. NOTE
Most computer monitors allow scanning the bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where you can see the bar code clearly, and bars and/or spaces are not merging.
If not using a USB cable or Synapse cable, select a host type (see each host chapter for specific host information) after the power-up beeps sound. This is only necessary upon the first power-up when connected to a new host. To return all features to default values, scan the Set Default Parameter on page 4-4. Throughout the programming bar code menus, asterisks indicate (*)default values.
* Indicates Default
*High Volume (00h)
Feature/Option
Page 48
4-2
Symbol DS6708 Digital Scanner Product Reference Guide
Scanning Sequence Examples In most cases, scanning one bar code sets the parameter value. For example, to set the beeper tone to high, scan the High Frequency (beeper tone) bar code listed under Beeper Tone on page 4-6. The digital scanner issues a fast warble beep and the LED turns green, signifying a successful parameter entry. Other parameters, such as Serial Response Time-Out or Data Transmission Formats, require scanning several bar codes. See these parameter descriptions for this procedure.
Errors While Scanning Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.
User Preferences/Miscellaneous Options Parameter Defaults Table 4-1 lists defaults for user preferences parameters. There are two ways to change the default values:
• Scan the appropriate bar codes in this guide. These new values replace the standard default values in memory. To recall the default parameter values, scan the Set Default Parameter on page 4-4.
• Configure the digital scanner using the 123Scan configuration program (see Chapter 12, 123Scan). NOTE
Table 4-1
See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.
User Preferences Parameter Defaults Parameter
Parameter Number
Default
Page Number
User Preferences Set Default Parameter
Restore Defaults
4-4
Parameter Scanning
ECh
Enable
4-5
Beeper Tone
91h
Medium
4-6
Beeper Volume
8Ch
High
4-7
Power Mode
80h
Continuous On
4-7
Time Delay to Low Power Mode
92h
1 Minute
4-8
Trigger Mode
8Ah
Auto Aim
4-9
Picklist Mode
F0h 92h
Disabled Always
4-10
Presentation Mode
F1h, 74h
3 Sec
4-11
Decode Session Timeout
88h
9.9 Sec
4-13
Timeout Between Decodes, Same Symbol
89h
0.6 Sec
4-13
Page 49
User Preferences & Miscellaneous Digital Scanner Options
Table 4-1
User Preferences Parameter Defaults (Continued) Parameter
Parameter Number
Default
Page Number
Beep After Good Decode
38h
Enable
4-14
Fuzzy 1D Processing
F1h, 02h
Enable
4-14
Decode Mirror Images
F1h, 19h
Never
4-15
Transmit Code ID Character
2Dh
None
4-16
Prefix Value
63h, 69h
7013 <CR><LF>
4-17
Suffix 1 Value Suffix 2 Value
62h, 68h 64h, 6Ah
7013 <CR><LF>
4-17
Scan Data Transmission Format
EBh
Data as is
4-18
FN1 Substitution Values
67h, 6Dh
Set
4-19
Transmit “No Read” Message
5Eh
Disable
4-20
Synapse Interface
F0h, ACh
Standard Synapse Connection
4-21
Miscellaneous Options
4-3
Page 50
4-4
Symbol DS6708 Digital Scanner Product Reference Guide
User Preferences Set Default Parameter Scan this bar code to return all parameters to the default values listed in Table A-1 on page A-1. You can reset the digital scanner to two types of defaults: factory defaults or custom defaults. Scan the appropriate bar code below to reset the scanner to its default settings and/or set its current settings as custom defaults.
• Restore Defaults - Scan this bar code to reset all default parameters as follows. • If you previously set custom defaults by scanning Write to Custom Defaults, scan Restore Defaults to retrieve and restore the decoder’s custom default settings. • If you did not set custom defaults, scan Restore Defaults to restore the factory default values listed in Table A-1.
• Set Factory Defaults - Scan this bar code to restore the factory default values listed in Table A-1. This deletes any custom defaults set.
• Write to Custom Defaults - Scan this bar code to set the current decoder settings as custom defaults. Once set, you can recover custom default settings by scanning Restore Defaults.
*Restore Defaults
Set Factory Defaults
Write to Custom Defaults
Page 51
User Preferences & Miscellaneous Digital Scanner Options
4-5
Parameter Scanning Parameter # ECh To disable decoding of parameter bar codes, including the Set Defaults parameter bar codes, scan the Disable Parameter Scanning bar code below. To re-enable decoding of parameter bar codes, scan Enable Parameter Scanning.
*Enable Parameter Scanning (01h)
Disable Parameter Scanning (00h)
Page 52
4-6
Symbol DS6708 Digital Scanner Product Reference Guide
Beeper Tone Parameter # 91h To select a decode beep frequency (tone), scan the Low Frequency, Medium Frequency, or High Frequency bar code.
Low Frequency (02h)
*Medium Frequency (Optimum Setting) (01h)
High Frequency (00h)
Page 53
User Preferences & Miscellaneous Digital Scanner Options
4-7
Beeper Volume Parameter # 8Ch To select a beeper volume, scan the Low Volume, Medium Volume, or High Volume bar code.
Low Volume (02h)
Medium Volume (01h)
*High Volume (00h)
Power Mode Parameter # 80h This parameter determines whether or not power remains on after a decode attempt. In reduced power mode, the digital scanner enters into a low power consumption mode to preserve battery life after each decode attempt. In continuous power mode, power remains on after each decode attempt.
*Continuous On (00h)
Reduced Power Mode (01h)
Page 54
4-8
Symbol DS6708 Digital Scanner Product Reference Guide
Time Delay to Low Power Mode Parameter # 92h NOTE
This parameter only applies when Power Mode is set to Reduced Power.
This parameter sets the time the digital scanner remains active after decoding. The digital scanner wakes upon trigger pull or when the host attempts to communicate with the digital scanner.
1 Second (11h)
5 Seconds (15h)
*1 Minute (21h)
5 Minutes (25h)
15 Minutes (2Bh)
1 Hour (31h)