Page 39
Chapter 3 Maintenance & Technical Specifications Introduction This chapter provides suggested scanner maintenance, troubleshooting, technical specifications, and signal descriptions (pinouts).
Maintenance Cleaning the scan window is the only maintenance required. A dirty window can affect scanning accuracy.
• Do not allow abrasive material to touch the window. • Remove any dirt particles with a damp cloth. • Wipe the window using a tissue moistened with ammonia/water. • Do not spray water or other cleaning liquids directly into the window.
Page 40
3-2
Symbol DS6708 Digital Scanner Product Reference Guide
Troubleshooting Table 3-1 Troubleshooting
Problem The aiming pattern does not appear when pressing the trigger.
Possible Causes
Possible Solutions
No power to the digital scanner.
If the configuration requires a power supply, re-connect the power supply.
Incorrect host interface cable is used.
Connect the correct host interface cable.
Interface/power cables are loose.
Re-connect cables.
Digital scanner is disabled.
For Synapse or IBM 468x mode, enable the digital scanner via the host interface. Otherwise, see the technical person in charge of scanning.
If using RS-232 Nixdorf B mode, CTS is not asserted.
Assert CTS line.
Aiming pattern is disabled.
Enable the aiming pattern. See Decode Aiming Pattern on page 5-5.
Scanner emits short low/short medium/short high beep sequence (power-up beep sequence) more than once.
The USB bus may put the digital scanner in a state where power to the digital scanner is cycled on and off more than once.
Normal during host reset.
Digital scanner emits aiming pattern, but does not decode the bar code.
Digital scanner is not programmed for the correct bar code type.
Program the digital scanner to read that type of bar code. See Chapter 13, Symbologies.
Bar code symbol is unreadable.
Scan test symbols of the same bar code type to determine if the bar code is defaced.
The symbol is not completely inside aiming pattern.
Move the symbol completely within the aiming pattern.
Digital scanner has not completed USB initialization.
Wait several seconds and scan again.
Digital scanner emits 4 short high beeps during decode attempt.
Page 41
Maintenance & Technical Specifications
3-3
Table 3-1 Troubleshooting (Continued)
Problem
Possible Causes
Possible Solutions
Digital scanner decodes bar code, but does not transmit the data to the host.
Digital scanner is not programmed for the correct host type.
Scan the appropriate host type programming bar code. See the chapter corresponding to the host type.
Interface cable is loose.
Re-connect the cable.
If 4 long low beeps are heard, a transmission error occurred.
Set the digital scanner's communication parameters to match the host's setting.
If 5 low beeps are heard, a conversion or format error occurred.
Configure the digital scanner's conversion parameters properly.
If low/high/low beeps are heard, an invalid ADF rule is detected.
Program the correct ADF rules.
If high/low beeps are heard, the digital scanner is buffering Code 39 data.
Normal scanning a Code 39 bar code and the Code 39 Buffering option is enabled.
Digital scanner is not programmed to work with the host.
Scan the appropriate host type programming bar code.
Host displays scanned data incorrectly.
For RS-232, set the digital scanner's communication parameters to match the host's settings. For a Keyboard Wedge configuration, program the system for the correct keyboard type, and turn off the CAPS LOCK key. Program the proper editing options (e.g., UPC-E to UPC-A Conversion). Digital scanner emits high/high/high/low beeps when not in use.
RS-232 receive error.
Normal during host reset. Otherwise, set the digital scanner's RS-232 parity to match the host setting.
Digital scanner emits low/high beeps during programming.
Input error or Cancel bar code was scanned.
Scan the correct numeric bar codes within range for the parameter programmed.
Digital scanner emits low/high/low/high beeps during programming.
Out of ADF parameter storage space.
Erase all rules and re-program with shorter rules.
The digital scanner may be out of Synapse parameter storage space.
Scan Set Synapse Defaults bar code for cables no longer in use and re-program the digital scanner for the current host interface.
Page 42
3-4
Symbol DS6708 Digital Scanner Product Reference Guide
Table 3-1 Troubleshooting (Continued)
Problem
Possible Causes
Possible Solutions
Digital scanner emits low/high/low beeps.
Clearing Code 39 buffer.
Normal when scanning the Code 39 Buffering Clear Buffer bar code or upon attempt to transmit an empty Code 39 buffer.
Digital scanner emits a power-up beep after changing USB host type.
The USB bus re-established power to the digital scanner.
Normal when changing USB host type.
Digital scanner emits one high beep when not in use.
In RS-232 mode, a <BEL> character was received and Beep on <BEL> option is enabled.
Normal when Beep on <BEL> is enabled and the digital scanner is in RS-232 mode.
NOTE
If after performing these checks the digital scanner still experiences problems, contact the distributor or call Motorola Enterprise Mobility Support. See page xvii for the telephone numbers.
Page 43
Maintenance & Technical Specifications
3-5
Technical Specifications Table 3-2 Technical Specifications
Item
Description
Physical Characteristics Dimensions (For Scanner Only; Not Including Base)
6.55 in. x 4.72 in. x 2.82 in. (16.6 cm x 11.9 cm x 7.1 cm) (H x L x W)
Weight:
6.4 oz. (182 gm)
Voltage & Current:
5 +/-10%VDC @ 350 mA
Color
Cash Register White or Twilight Black
Performance Characteristics Light Source
Aiming: 650 nm laser diode Illumination: 630 nm LED
Field of View (Vertical x Horizontal)
34º (V) x 43º (H)
Roll Pitch Yaw
360º +/- 65º +/- 60º
Symbology Decode Capability 1D
UPC/EAN and with supplementals, Code 39, Code 39 Full ASCII, Tri-optic Code 39, GS1 DataBar Variants (formerly RSS), GS1-128 (formerly UCC/EAN-128), Code 128, Code 128 Full ASCII, Code 93, Codabar (NW1), Interleaved 2 of 5, Discrete 2 of 5, MSI, Code 11, IATA, Bookland EAN, Code 32
PDF417 (& Variants)
PDF417, MicroPDF417, Composite Codes
Postal
U.S. Postnet and Planet, U.K., Japan, Australian, Netherlands KIX Code, USPS 4CB/One Code/Intelligent Mail, UPU FICS Postal
2D
MaxiCode, Data Matrix (ECC 200), QR Code, Micro QR, Aztec
Page 44
3-6
Symbol DS6708 Digital Scanner Product Reference Guide
Table 3-2 Technical Specifications (Continued)
Item
Description
Typical Working Distance
5 mil (Code 39): 10 mil (I 2 of 5): 13 mil (100% UPC/EAN): Postnet 20 mil (Code 39): PDF417 (6.6 Mil): QR Code (10 Mil) PDF417 (10 Mil): MicroPDF (10 Mil) Data Matrix (10 Mil): Maxicode (35 Mil):
0.9 - 5.4 in. (2.3 - 13.7 cm) 1.0 - 7.9 in. (2.5 - 20.1 cm) 0.9 - 8.4 in. (2.3 - 21.3 cm) 2.6 - 12.5 in. (6.6 - 31.8 cm) 0.9 - 12.9 in. (2.3 - 32.8 cm) 3.4 - 5.7 in. (8.6 - 14.5 cm) 2.6 - 6.8 in. (6.6 - 17.3 cm) 1.4 - 6.2 in. (3.6 - 15.7 cm) 2.3 - 7.5 in. (5.8 - 19.1 cm) 1.1 - 7.5 in. (2.8 - 19.1 cm) 1.5 - 12.8 in. (3.8 - 32.5 cm)
Print Contrast
25% minimum reflectance
Motion Tolerances
Horizontal Velocity: 5 in. (12.7 cm) per second
Interfaces Supported
RS-232C (Standard, Nixdorf, ICL, & Fujitsu); USB (Standard, IBM SurePOS, Macintosh); IBM 468x/469x; Keyboard Wedge; and, Synapse Connectivity allows for connectivity to all of the above plus many non-standard interfaces.
User Environment Operating Temperature
32º F to 104º F (0º C to 40º C)
Storage Temperature
-40º F to 158º F (-40º C to 70º C)
Humidity
5% to 95%, non-condensing
Drop Specifications (For Scanner Only; Not Including Base)
Withstands multiple 5 ft. (1.52 m) drops to concrete at operating temperature extremes, and multiple 6 ft. (1.8 m) drops to concrete at room temperature (23º C).
Ambient Light Immunity
Immune to normal artificial indoor and natural outdoor (direct sunlight) lighting.
Regulatory Electrical Safety
UL6950-1, CSA C22.2 No. 60950-1, EN60950-1 / IEC60950-1
Laser Safety
EN60825-1:1994 +A1: 2002 +A2 :2001, IEC60825-1, 21CFR1040.10 and 21CFR1040.11, CDRH Class II, IEC Class 2
EMI/RFI
FCC Part 15 Class B, ICES-003 Class B, CISPR 22, CISPR 24 Medical Electrical Equipment: EN60601-1-2: 2002
RoHS
Compliance with RoHS Directive 2002/95/EEC
Mounting Options (Accessories)
Intellistand with adjustable height: 5-10 in. (12.7-25.4 cm) and adjustable angle: 0º - 90º Desktop & Wall-mount holders are also available.
Power Supplies
Power supplies are available for applications that do not supply power over the host cable.
Page 45
Maintenance & Technical Specifications
3-7
Digital Scanner Signal Descriptions Bottom of digital scanner
Cable interface port
Pin 10
Pin 1
Interface cable modular connector
Figure 3-1 Digital Scanner Cable Pinouts
The signal descriptions in Table 3-3 apply to the connectors on the Symbol DS6708 digital scanner and are for reference only. Table 3-3 Symbol DS6708 Digital Scanner Signal Pin-outs
Pin
IBM
Synapse
RS-232
Keyboard Wedge
Wand
USB
Scanner Emulation
1
Reserved
SynClock
Reserved
Reserved
Reserved
Jump to Pin 6
DBP
2
Power
Power
Power
Power
Power
Power
Power
3
Ground
Ground
Ground
Ground
Ground
Ground
Ground
4
IBM_A(+)
Reserved
TxD
KeyClock
DBP
Reserved
SOS
5
Reserved
Reserved
RxD
TermData
CTS
D+
Decode
6
IBM_B(-)
SynData
RTS
KeyData
RTS
Jump to Pin 1
Trigger
7
Reserved
Reserved
CTS
TermClock
Reserved
D-
Enable
8
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
9
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
10
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Page 46
3-8
Symbol DS6708 Digital Scanner Product Reference Guide