Page 337

Appendix A Standard Default Parameters

Table A-1

Standard Default Parameters Table Parameter

Parameter Number

Default

Page Number

User Preferences Set Default Parameter

Restore Defaults

4-4

Parameter Scanning

ECh

Enable

4-5

Beeper Tone

91h

Medium

4-5

Beeper Volume

8Ch

High

4-5

Power Mode

80h

Continuous On

4-6

Time Delay to Low Power Mode

92h

1 Minute

4-7

Trigger Mode

8Ah

Auto Aim

4-8

Picklist Mode

F0h, 92h

Disabled Always

4-9

Decode Session Timeout

88h

9.9 Sec

4-10

Timeout Between Decodes, Same Symbol

89h

0.6 Sec

4-10

Beep After Good Decode

38h

Enable

4-11

Decoding Illumination

F0h, 2Ah

Enable

4-11

DP Illumination

F1h, 3Bh

Auto

4-12

Decode Aiming Pattern

F0h, 32h

Enable

4-13

Fuzzy 1D Processing

F1h, 02h

Enable

4-13

Decode Mirror Images

F1h, 19h

Never

4-14

1

User selection is required to configure this interface and this is the most common selection.

Page 338

A-2

Symbol DS6707 Digital Imager Scanner Product Reference Guide

Table A-1

Standard Default Parameters Table (Continued) Parameter

Parameter Number

Default

Page Number

Miscellaneous Scanner Options Transmit Code ID Character

2Dh

None

4-15

Prefix Value

63h, 69h

7013 <CR><LF>

4-16

Suffix 1 Value Suffix 2 Value

62h, 68h 64h, 6Ah

7013 <CR><LF>

4-16

Scan Data Transmission Format

EBh

Data as is

4-17

FN1 Substitution Values

67h, 6Dh

Set

4-18

Transmit “No Read” Message

5Eh

Disable

4-19

Operational Modes

N/A

N/A

5-4

Low Light Enhancement

F1h 64h

Disable

5-5

Presentation Mode Field of View

F1h 61h

Default (Reduced)

5-5

Image Capture Autoexposure

F0h 68h

Enable

5-6

Image Capture Illumination

F0h 69h

Enable

5-6

Illumination Bank Control

F1h 3Bh

Full

5-7

Fixed Exposure

F4h, F1h, 37h

100

5-8

Fixed Gain

F1h 38h

50

5-8

Gain Exposure Priority for Snapshot Mode

F1h 32h

Autodetect

5-9

Snapshot Mode Timeout

F0h 43h

0 (30 seconds)

5-10

Snapshot Aiming Pattern

F0h 2Ch

Enable

5-10

Image Cropping

F0h 2Dh

Disable

5-11

Crop to Pixel Addresses

F4h F0h 3Bh; F4h F0h 3Ch; F4h F0h 3Dh; F4h F0h 3Eh

0 top, 0 left, 1023 bottom, 1279 right

5-12

Image Size (Number of Pixels)

F0h 2Eh

Full

5-13

Image Brightness (Target White)

F0h 86h

180

5-14

JPEG Image Options

F0h 2Bh

Quality

5-14

JPEG Target File Size

F1h 31h

160 kB

5-15

Imaging Preferences

1

User selection is required to configure this interface and this is the most common selection.

Page 339

Standard Default Parameters

Table A-1

Standard Default Parameters Table (Continued) Parameter

Parameter Number

Default

Page Number

JPEG Quality and Size Value

F0h 31h

65

5-15

Image Enhancement

F1h 34h

Off (0)

5-16

Image File Format Selection

F0h 30h

JPEG

5-17

Bits per Pixel (BPP)

F0h 2Fh

8 BPP

5-18

Signature Capture

5Dh

Disable

5-19

Signature Capture Image File Format Selection

F0h 39h

JPEG

5-20

Signature Capture Bits per Pixel (BPP)

F0h 3Ah

8 BPP

5-21

Signature Capture Width

F4h F0h 6Eh

400

5-22

Signature Capture Height

F4h F0h 6Fh

100

5-22

Signature Capture JPEG Quality

F0h A5h

65

5-22

Video View Finder

F0h 44h

Disable

5-23

Target Video Frame Size

F0h 48h

2200 bytes

5-23

Video View Finder Image Size

F0h 49h

1700 bytes

5-24

Baud Rate

9Ch

9600

6-4

Parity

9Eh

None

6-6

Check Parity

97h

Enable

6-7

Software Handshaking

9Fh

ACK/NAK

6-7

Host RTS Line State

9Ah

Low

6-8

Decode Data Packet Format

EEh

Send Raw Decode Data

6-8

Stop Bits

9Dh

1

6-9

Host Serial Response Time-out

9Bh

2 sec

6-10

Host Character Time-out

EFh

200 msec

6-11

Multipacket Option

F0h 4Eh

Option 1

6-12

Interpacket Delay

F0h 4Fh

0 ms

6-13

Decode Event

F0h 00h

Disable

6-14

Boot Up Event

F0h 02h

Disable

6-15

SSI Host Preferences

SSI Event Reporting

1

User selection is required to configure this interface and this is the most common selection.

A-3

Page 340

A-4

Symbol DS6707 Digital Imager Scanner Product Reference Guide

Table A-1

Standard Default Parameters Table (Continued) Parameter

Parameter Event

Parameter Number F0h 03h

Default

Page Number

Disable

6-15

USB Device Type

HID Keyboard Emulation

7-4

Symbol Native API (SNAPI) Status Handshaking

Enable

7-5

USB Country Keyboard Types (Country Codes)

North American

7-6

USB Keystroke Delay

No Delay

7-8

USB CAPS Lock Override

Disable

7-8

USB Ignore Unknown Characters

Enable

7-9

Emulate Keypad

Disable

7-9

Emulate Keypad with Leading Zero

Disable

7-10

USB Keyboard FN1 Substitution

Disable

7-10

Function Key Mapping

Disable

7-11

Simulated Caps Lock

Disable

7-11

Convert Case

No Case Conversion

7-12

RS-232 Host Types

Standard1

8-6

Baud Rate

9600

8-7

Parity Type

None

8-9

Stop Bit Select

1 Stop Bit

8-10

Data Bits

8-Bit

8-10

Check Receive Errors

Enable

8-11

Hardware Handshaking

None

8-11

Software Handshaking

None

8-13

Host Serial Response Time-out

2 Sec

8-15

RTS Line State

Low RTS

8-16

Beep on <BEL>

Disable

8-16

Intercharacter Delay

0 msec

8-17

USB Host Parameters

RS-232 Host Parameters

1

User selection is required to configure this interface and this is the most common selection.

Page 341

Standard Default Parameters

Table A-1

Standard Default Parameters Table (Continued) Parameter

Parameter Number

Default

Page Number

Nixdorf Beep/LED Options

Normal Operation

8-18

Ignore Unknown Characters

Send Bar Code

8-18

None1

9-1

123Scan Configuration Tool 123Scan Configuration UPC/EAN UPC-A

01h

Enable

10-7

UPC-E

02h

Enable

10-7

UPC-E1

0Ch

Disable

10-8

EAN-8/JAN 8

04h

Enable

10-8

EAN-13/JAN 13

03h

Enable

10-9

Bookland EAN

53h

Disable

10-9

Decode UPC/EAN/JAN Supplementals (2 and 5 digits)

10h

Ignore

10-10

User-Programmable Supplementals Supplemental 1: Supplemental 2:

F1h 43h F1h 44h

10-13

UPC/EAN/JAN Supplemental Redundancy

50h

10

10-14

Transmit UPC-A Check Digit

28h

Enable

10-14

Transmit UPC-E Check Digit

29h

Enable

10-15

Transmit UPC-E1 Check Digit

2Ah

Enable

10-15

UPC-A Preamble

22h

System Character

10-16

UPC-E Preamble

23h

System Character

10-17

UPC-E1 Preamble

24h

System Character

10-18

Convert UPC-E to A

25h

Disable

10-19

Convert UPC-E1 to A

26h

Disable

10-19

EAN-8/JAN-8 Extend

27h

Disable

10-20

Bookland ISBN Format

F1h 40h

ISBN-10

10-21

UCC Coupon Extended Code

55h

Disable

10-22

1User selection is required to configure this interface and this is the most common selection.

A-5

Page 342

A-6

Symbol DS6707 Digital Imager Scanner Product Reference Guide

Table A-1

Standard Default Parameters Table (Continued) Parameter

Parameter Number

Default

Page Number

Code 128 Code 128

08h

Enable

10-23

Set Length(s) for Code 128

D1h D2h

Any Length

10-23

GS1-128 (formerly UCC/EAN-128)

0Eh

Enable

10-25

ISBT 128

54h

Enable

10-25

Code 39

00h

Enable

10-26

Trioptic Code 39

0Dh

Disable

10-26

Convert Code 39 to Code 32 (Italian Pharmacy Code)

56h

Disable

10-27

Code 32 Prefix

E7h

Disable

10-27

Set Length(s) for Code 39

12h 13h

2 to 55

10-28

Code 39 Check Digit Verification

30h

Disable

10-29

Transmit Code 39 Check Digit

2Bh

Disable

10-30

Code 39 Full ASCII Conversion

11h

Disable

10-30

Buffer Code 39

71h

Disable

10-31

Code 93

09h

Disable

10-34

Set Length(s) for Code 93

1Ah 1Bh

4 to 55

10-34

Code 11

0Ah

Disable

10-36

Set Lengths for Code 11

1Ch 1Dh

4 to 55

10-36

Code 11 Check Digit Verification

34h

Disable

10-38

Transmit Code 11 Check Digit(s)

2Fh

Disable

10-39

Interleaved 2 of 5 (ITF)

06h

Enable

10-40

Set Lengths for I 2 of 5

16h 17h

14

10-40

I 2 of 5 Check Digit Verification

31h

Disable

10-42

Transmit I 2 of 5 Check Digit

2Ch

Disable

10-42

Code 39

Code 93

Code 11

Interleaved 2 of 5 (ITF)

1

User selection is required to configure this interface and this is the most common selection.

Page 343

Standard Default Parameters

Table A-1

Standard Default Parameters Table (Continued) Parameter

Convert I 2 of 5 to EAN 13

Parameter Number

Default

Page Number

52h

Disable

10-43

Discrete 2 of 5

05h

Disable

10-44

Set Length(s) for D 2 of 5

14h 15h

12

10-44

Codabar

07h

Disable

10-46

Set Lengths for Codabar

18h 19h

5 to 55

10-46

CLSI Editing

36h

Disable

10-48

NOTIS Editing

37h

Disable

10-48

MSI

0Bh

Disable

10-49

Set Length(s) for MSI

1Eh 1Fh

4 to 55

10-49

MSI Check Digits

32h

One

10-50

Transmit MSI Check Digit

2Eh

Disable

10-51

MSI Check Digit Algorithm

33h

Mod 10/Mod 10

10-51

Inverse 1D Decoder

F1h 4Ah

SR, DC: Regular DP, HD: Autodetect

10-52

US Postnet

59h

Enable

10-53

US Planet

5Ah

Enable

10-53

UK Postal

5Bh

Enable

10-54

Transmit UK Postal Check Digit

60h

Enable

10-54

Japan Postal

F0h 22h

Enable

10-55

Australian Postal

F0h 23h

Enable

10-55

Dutch Postal

F0h 46h

Enable

10-56

4State Postal

F1h 50h

Disable

10-56

Post US4

F1h 63h

Disable

10-57

Transmit US Postal Check Digit

5Fh

Enable

10-57

Discrete 2 of 5 (DTF)

Codabar (NW - 7)

MSI

Postal Codes

1

User selection is required to configure this interface and this is the most common selection.

A-7

Page 344

A-8

Symbol DS6707 Digital Imager Scanner Product Reference Guide

Table A-1

Standard Default Parameters Table (Continued) Parameter

Parameter Number

Default

Page Number

GS1 DataBar GS1 DataBar-14

F0h 52h

Enable

10-58

GS1 DataBar Limited

F0h 53h

Enable

10-58

GS1 DataBar Expanded

F0h 54h

Enable

10-59

Convert GS1 DataBar to UPC/EAN

F0h 8Dh

Disable

10-59

Composite CC-C

F0h 55h

Disable

10-60

Composite CC-A/B

F0h 56h

Disable

10-60

Composite TLC-39

F0h 73h

Disable

10-61

UPC Composite Mode

F0h 58h

Always Linked

10-62

Composite Beep Mode

F0h 8Eh

Beep As Each Code Type is Decoded

10-63

GS1-128 Emulation Mode for UCC/EAN Composite Codes

F0h ABh

Disable

10-63

PDF417

0Fh

Enable

10-64

MicroPDF417

E3h

Disable

10-64

Code 128 Emulation

7Bh

Disable

10-65

Data Matrix

F0h 24h

Enable

10-66

Data Matrix Inverse

F1h 4Ch

SR, DC: Regular DP, HD: Autodetect

10-67

Maxicode

F0h 26h

Enable

10-68

QR Code

F0h 25h

Enable

10-68

MicroQR

F1h 3Dh

Enable

10-69

QR Inverse

F1h 4Bh

SR, DC: Regular DP, HD: Autodetect

10-70

Aztec

F1h 3Eh

Enable

10-71

Aztec Inverse

F1h 4Dh

SR, DC: Regular DP, HD: Autodetect

10-72

Composite

2D Symbologies

1

User selection is required to configure this interface and this is the most common selection.

Page 345

Standard Default Parameters

Table A-1

Standard Default Parameters Table (Continued) Parameter

Parameter Number

Default

Page Number

Symbology-Specific Security Levels Redundancy Level

4Eh

1

10-73

Security Level

4Dh

1

10-75

Intercharacter Gap Size

F0h 7Dh

Normal

10-76

Report Version

10-76

Macro PDF Flush Macro PDF Buffer

10-77

Abort Macro PDF Entry

10-77

1User selection is required to configure this interface and this is the most common selection.

A-9

Page 346

A - 10 Symbol DS6707 Digital Imager Scanner Product Reference Guide