The text of a manual · part 22 of 48
Symbol DS6707 Digital Imager Scanner Product Reference Guide, pages 153 to 162
Pages 153 to 162 of 394: 123Scan; Symbologies
The original document is the PDF (8.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol DS-6707
Page 153
Chapter 9 123Scan Introduction 123Scan is a Windows®-based utility that programs the digital imager scanner with all parameters including Advanced Data Formatting (ADF) rules. An ADF rule modifies bar code data before sending it to the host to ensure compatibility between bar coded data and the host application. Program digital imager scanners via PC download or by scanning a sheet of bar codes generated by the 123Scan utility. Digital imager scanner programming is saved in a file for electronic distribution. The 123Scan program includes a help file.
Communication with 123Scan To communicate with the 123Scan program which runs on a host computer running a Windows operating system, use an RS-232 cable to connect the digital imager scanner to the host computer (see Connecting an RS-232 Interface on page 8-2). 123Scan requirements:
• Host computer with Windows 98, Windows NT, Windows 2000, or Windows XP • Digital imager scanner • RS-232 cable.
123Scan Parameter To communicate with the 123Scan program, load 123Scan, included in the documentation CD-ROM, onto the host computer, and scan the bar code below. Refer to 123Scan instructions for programming the digital imager scanner. Scan the bar code below to enable the 123Scan interface on the digital imager scanner.
123Scan Configuration
Page 154
9-2
Symbol DS6707 Digital Imager Scanner Product Reference Guide
Page 155
Chapter 10 Symbologies Introduction This chapter describes symbology features and provides programming bar codes for selecting these features. Before programming, follow the instructions in Chapter 1, Getting Started. To set feature values, scan a single bar code or a short bar code sequence. The settings are stored in non-volatile memory and are preserved even when you power down the digital imager scanner. NOTE
Most computer monitors allow scanning the bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where you can see the bar code clearly, and bars and/or spaces are not merging.
Select a host type (see each host chapter for specific host information) after the power-up beeps sound. This is only necessary upon the first power-up when connecting to a new host. To return all features to default values, scan the Set Default Parameter on page 4-4. Throughout the programming bar code menus, asterisks (*) indicate default values.
* Indicates Default
*Enable UPC-A (01h)
Feature/Option Option Hex Value for programming via SSI command
Scanning Sequence Examples In most cases, scanning one bar code sets the parameter value. For example, to transmit bar code data without the UPC-A check digit, simply scan the Do Not Transmit UPC-A Check Digit bar code under Transmit UPC-A Check Digit on page 10-14. The digital imager scanner issues a fast warble beep and the LED turns green, signifying a successful parameter entry. Other parameters, such as Set Length(s) for D 2 of 5 require scanning several bar codes. See the individual parameter, such as Set Length(s) for D 2 of 5, for this procedure.
Page 156
10 - 2 Symbol DS6707 Digital Imager Scanner Product Reference Guide
Errors While Scanning Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.
Symbology Parameter Defaults Table 10-1 lists the defaults for all symbologies parameters. There are two ways to change the default values:
• Scan the appropriate bar codes in this guide. These new values replace the standard default values in memory. To recall the default parameter values, scan the Set Default Parameter on page 4-4.
• Download data through the device’s serial port using SSI. Hexadecimal parameter numbers appear in this chapter below the parameter title, and options appear in parenthesis beneath the accompanying bar codes. See the Simple Serial Interface (SSI) Programmer’s Guide for detailed instructions for changing parameters using this method. NOTE
See Appendix A, Standard Default Parameters for all user preferences, hosts, and miscellaneous default parameters.
Table 10-1 Parameter Defaults
Parameter
Parameter Number
Default
Page Number
UPC/EAN UPC-A
01h
Enable
10-7
UPC-E
02h
Enable
10-7
UPC-E1
0Ch
Disable
10-8
EAN-8/JAN 8
04h
Enable
10-8
EAN-13/JAN 13
03h
Enable
10-9
Bookland EAN
53h
Disable
10-9
Decode UPC/EAN/JAN Supplementals (2 and 5 digits)
10h
Ignore
10-10 10-13
User-Programmable Supplementals Supplemental 1: Supplemental 2:
F1h 43h F1h 44h
UPC/EAN/JAN Supplemental Redundancy
50h
10
10-14
Transmit UPC-A Check Digit
28h
Enable
10-14
Transmit UPC-E Check Digit
29h
Enable
10-14
Transmit UPC-E1 Check Digit
2Ah
Enable
10-15
UPC-A Preamble
22h
System Character
10-16
UPC-E Preamble
23h
System Character
10-16
Page 157
Symbologies 10 - 3
Table 10-1 Parameter Defaults (Continued)
Parameter
Parameter Number
Default
Page Number
UPC-E1 Preamble
24h
System Character
10-18
Convert UPC-E to A
25h
Disable
10-19
Convert UPC-E1 to A
26h
Disable
10-19
EAN-8/JAN-8 Extend
27h
Disable
10-20
Bookland ISBN Format
F1h 40h
ISBN-10
10-21
UCC Coupon Extended Code
55h
Disable
10-22
Code 128
08h
Enable
10-23
Set Length(s) for Code 128
D1h D2h
Any Length
10-23
GS1-128 (formerly UCC/EAN-128)
0Eh
Enable
10-25
ISBT 128
54h
Enable
10-25
Code 39
00h
Enable
10-26
Trioptic Code 39
0Dh
Disable
10-26
Convert Code 39 to Code 32 (Italian Pharmacy Code)
56h
Disable
10-27
Code 32 Prefix
E7h
Disable
10-27
Set Length(s) for Code 39
12h 13h
2 to 55
10-28
Code 39 Check Digit Verification
30h
Disable
10-29
Transmit Code 39 Check Digit
2Bh
Disable
10-30
Code 39 Full ASCII Conversion
11h
Disable
10-30
Buffer Code 39
71h
Disable
10-31
Code 93
09h
Disable
10-34
Set Length(s) for Code 93
1Ah 1Bh
4 to 55
10-34
Code 11
0Ah
Disable
10-36
Set Lengths for Code 11
1Ch 1Dh
4 to 55
10-36
Code 11 Check Digit Verification
34h
Disable
10-38
Transmit Code 11 Check Digit(s)
2Fh
Disable
10-39
Code 128
Code 39
Code 93
Code 11
Page 158
10 - 4 Symbol DS6707 Digital Imager Scanner Product Reference Guide
Table 10-1 Parameter Defaults (Continued)
Parameter
Parameter Number
Default
Page Number
Interleaved 2 of 5 (ITF) Interleaved 2 of 5 (ITF)
06h
Enable
10-40
Set Lengths for I 2 of 5
16h 17h
14
10-40
I 2 of 5 Check Digit Verification
31h
Disable
10-42
Transmit I 2 of 5 Check Digit
2Ch
Disable
10-42
Convert I 2 of 5 to EAN 13
52h
Disable
10-43
Discrete 2 of 5
05h
Disable
10-44
Set Length(s) for D 2 of 5
14h 15h
12
10-44
Codabar
07h
Disable
10-46
Set Lengths for Codabar
18h 19h
5 to 55
10-46
CLSI Editing
36h
Disable
10-48
NOTIS Editing
37h
Disable
10-48
MSI
0Bh
Disable
10-49
Set Length(s) for MSI
1Eh 1Fh
4 to 55
10-49
MSI Check Digits
32h
One
10-50
Transmit MSI Check Digit
2Eh
Disable
10-51
MSI Check Digit Algorithm
33h
Mod 10/Mod 10
10-51
Inverse 1D
F1h 4Ah
SR, DC: Regular DP, HD: Autodetect
10-52
US Postnet
59h
Enable
10-53
US Planet
5Ah
Enable
10-53
UK Postal
5Bh
Enable
10-54
Transmit UK Postal Check Digit
60h
Enable
10-54
Japan Postal
F0h 22h
Enable
10-55
Australian Postal
F0h 23h
Enable
10-55
Dutch Postal
F0h 46h
Enable
10-56
Discrete 2 of 5 (DTF)
Codabar (NW - 7)
MSI
Postal Codes
Page 159
Symbologies 10 - 5
Table 10-1 Parameter Defaults (Continued)
Parameter
Parameter Number
Default
Page Number
4State Postal
F1h 50h
Disable
10-56
Post US4
F1h 63h
Disable
10-57
Transmit US Postal Check Digit
5Fh
Enable
10-57
GS1 DataBar-14
F0h 52h
Enable
10-58
GS1 DataBar Limited
F0h 53h
Enable
10-58
GS1 DataBar Expanded
F0h 54h
Enable
10-59
Convert GS1 DataBar to UPC/EAN
F0h 8Dh
Disable
10-59
Composite CC-C
F0h 55h
Disable
10-60
Composite CC-A/B
F0h 56h
Disable
10-60
Composite TLC-39
F0h 73h
Disable
10-61
UPC Composite Mode
F0h 58h
Always Linked
10-62
Composite Beep Mode
F0h 8Eh
Beep As Each Code Type is Decoded
10-63
GS1-128 Emulation Mode for UCC/EAN Composite Codes
F0h ABh
Disable
10-63
PDF417
0Fh
Enable
10-64
MicroPDF417
E3h
Disable
10-64
Code 128 Emulation
7Bh
Disable
10-65
Data Matrix
F0h 24h
Enable
10-66
Data Matrix Inverse
F1h 4Ch
SR, DC: Regular DP, HD: Autodetect
10-67
Maxicode
F0h 26h
Enable
10-68
QR Code
F0h 25h
Enable
10-68
MicroQR
F1h 3Dh
Enable
10-69
QR Inverse
F1h 4Bh
SR, DC: Regular DP, HD: Autodetect
10-70
Aztec
F1h 3Eh
Enable
10-71
Aztec Inverse
F1h 4Dh
SR, DC: Regular DP, HD: Autodetect
10-72
GS1 DataBar
Composite
2-D Symbologies
Page 160
10 - 6 Symbol DS6707 Digital Imager Scanner Product Reference Guide
Table 10-1 Parameter Defaults (Continued)
Parameter
Parameter Number
Default
Page Number
Symbology-Specific Security Levels Redundancy Level
4Eh
1
10-73
Security Level
4Dh
1
10-75
Intercharacter Gap Size
F0h 7Dh
Normal
10-76
Report Version
10-76
Macro PDF Flush Macro PDF Buffer
10-77
Abort Macro PDF Entry
10-77
Page 161
Symbologies 10 - 7
UPC/EAN Enable/Disable UPC-A Parameter # 01h To enable or disable UPC-A, scan the appropriate bar code below.
*Enable UPC-A (01h)
Disable UPC-A (00h)
Enable/Disable UPC-E Parameter # 02h To enable or disable UPC-E, scan the appropriate bar code below.
*Enable UPC-E (01h)
Disable UPC-E (00h)
Page 162
10 - 8 Symbol DS6707 Digital Imager Scanner Product Reference Guide
Enable/Disable UPC-E1 Parameter # 0Ch UPC-E1 is disabled by default. To enable or disable UPC-E1, scan the appropriate bar code below. NOTE
UPC-E1 is not a UCC (Uniform Code Council) approved symbology.
Enable UPC-E1 (01h)
*Disable UPC-E1 (00h)
Enable/Disable EAN-8/JAN-8 Parameter # 04h To enable or disable EAN-8/JAN-8, scan the appropriate bar code below.
*Enable EAN-8/JAN-8 (01h)
Disable EAN-8/JAN-8 (00h)