The text of a manual · part 15 of 48
Symbol DS6707 Digital Imager Scanner Product Reference Guide: SSI Interface, pages 99 to 106
Pages 99 to 106 of 394, from Symbol DS6707 Digital Imager Scanner Product Reference Guide
The original document is the PDF (8.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol DS-6707
Page 99
SSI Interface
6-9
Stop Bit Select Parameter # 9Dh The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving (host) device for the next character in the serial data stream. Set the number of stop bits (one or two) to match host device requirements.
*1 Stop Bit (01h)
2 Stop Bits (02h)
Page 100
6 - 10 Symbol DS6707 Digital Imager Scanner Product Reference Guide
Host Serial Response Time-out Parameter # 9Bh This parameter specifies how long the decoder waits for an ACK or NAK before resending. Also, if the decoder wants to send, and the host was already granted permission to send, the decoder waits for the designated time-out before declaring an error. To set the delay period (options are 2, 5, 7.5, or 9.9 seconds), scan one of the following bar codes. NOTE
Other values are available via SSI command.
*Low - 2 Seconds (14h)
Medium - 5 Seconds (32h)
High - 7.5 Seconds (4Bh)
Maximum - 9.9 Seconds (63h)
Page 101
SSI Interface 6 - 11
Host Character Time-out Parameter # EFh This parameter determines the maximum time the decoder waits between characters transmitted by the host before discarding the received data and declaring an error. To set the delay period (options are 200, 500, 750, or 990 ms), scan one of the following bar codes. NOTE
Other values are available via SSI command.
*Low - 200 ms (0Ah)
Medium - 500 ms (32h)
High - 750 ms (4Bh)
Maximum - 990 ms (63h)
Page 102
6 - 12 Symbol DS6707 Digital Imager Scanner Product Reference Guide
Multipacket Option Parameter # F0h, 4Eh This parameter controls ACK/NAK handshaking for multi-packet transmissions. • Multi-Packet Option 1: The host sends an ACK / NAK for each data packet during a multi-packet transmission. • Multi-Packet Option 2: The digital imager scanner sends data packets continuously, with no ACK/NAK handshaking to pace the transmission. The host, if overrun, can use hardware handshaking to temporarily delay digital imager scanner transmissions. At the end of transmission, the digital imager scanner waits for a CMD_ACK or CMD_NAK. • Multi-Packet Option 3: Option 3 is the same as option 2 with the addition of a programmable interpacket delay.
*Multipacket Option 1 (00h)
Multipacket Option 2 (01h)
Multipacket Option 3 (02h)
Page 103
SSI Interface 6 - 13
Interpacket Delay Parameter # F0h, 4Fh This parameter specifies the interpacket delay when Multipacket Option 3 is selected. To set the delay period (options are 0, 25, 50, 75, or 99 ms), scan one of the following bar codes. NOTE
Other values are available via SSI command.
*Minimum - 0 ms (00h)
Low - 25 ms (19h)
Medium - 50 ms (32h)
High - 75 ms (4Bh)
Maximum - 99 ms (63h)
Page 104
6 - 14 Symbol DS6707 Digital Imager Scanner Product Reference Guide
Event Reporting The host can request the digital imager scanner to provide certain information (events) relative to the digital imager scanner’s behavior. Enable or disable the events listed in Table 6-2 and on the following pages by scanning the appropriate bar codes. Table 6-2 Event Codes
Event Class
Event
Code Reported
Decode Event
Non parameter decode
0x01
Boot Up Event
System power-up
0x03
Parameter Event
Parameter entry error Parameter stored Defaults set (and parameter event is enabled by default) Number expected
0x07 0x08 0x0A 0x0F
Decode Event Parameter # F0h, 00h When enabled, the digital imager scanner generates a message to the host when it successfully decodes a bar code. When disabled, no notification is sent.
Enable Decode Event (01h)
*Disable Decode Event (00h)
Page 105
SSI Interface 6 - 15
Boot Up Event Parameter # F0h, 02h When enabled, the digital imager scanner generates a message to the host when power is applied. When disabled, no notification is sent.
Enable Boot Up Event (01h)
*Disable Boot Up Event (00h)
Parameter Event Parameter # F0h, 03h When enabled, the digital imager scanner generates a message to the host when one of the events specified in Table 6-2 on page 6-14 occurs. When disabled, no notification is sent.
Enable Parameter Event (01h)
*Disable Parameter Event (00h)
Page 106