The text of a manual · part 9 of 50
Symbol DS3478 Smart Focus Digital Scanner Product Reference Guide: User Preferences
Pages 55 to 68 of 416, from Symbol DS3478 Smart Focus Digital Scanner Product Reference Guide
The original document is the PDF (9.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol DS-3478
Page 55
Chapter 4 User Preferences Introduction This chapter describes each user preference feature and provides programming bar codes for selecting these features for the digital scanner. The digital scanner ships with the settings shown in the User Preferences Default Table on page 4-2 (also see Appendix A, Standard Default Parameters for all host and miscellaneous defaults). If the default values suit the requirements, programming is not necessary. Set feature values by scanning single bar codes or short bar code sequences. The settings are stored in non-volatile memory and are preserved when you power down the digital scanner. The digital scanner communicates with the host through the digital scanner cradle. During setup, you pair the digital scanner with a cradle, which connects to the host through one of several interfaces (see Pairing on page 1-9 and the applicable host interface chapter). Each cradle can pair with up to four digital scanners. If not using a Synapse or USB cable, select the host type (see the specific host chapter) after the digital scanner emits power-up beeps. This is only necessary upon the first power-up when connecting to a new host. NOTE
Disconnect the power supply before changing host cables or the digital scanner may not recognize the new host.
To return all features to their default values, scan Set All Defaults on page 4-3. Throughout the programming bar code menus, asterisks (*) indicate default values.
* Indicates Default
*Medium Frequency
Feature/Option
Page 56
4-2
Symbol DS3478 Product Reference Guide
Scanning Sequence Examples In most cases, scan only one bar code to set a parameter value. For example, to set the beeper tone to high, scan the High Frequency (beeper tone) bar code under Beeper Tone on page 4-4. The digital scanner issues a fast warble beep and the LED turns green, indicating a successful parameter entry. Other parameters, such as Decode Session Timeout, require scanning several bar codes. See the parameter description for this procedure.
Errors While Scanning Unless otherwise specified, if you make an error during a scanning sequence, re-scan the correct parameter.
User Preferences Default Parameters Table 4-1 lists the defaults for user preference parameters. To change any option, scan the appropriate bar code(s) provided in User Preferences on page 4-3. NOTE
Table 4-1
See Appendix A, Standard Default Parameters for all user preference, host, symbology, and miscellaneous default parameters.
User Preferences Default Table Parameter
Default
Page Number
User Preferences Set Default Parameter
All Defaults
4-3
Parameter Scanning
Enable
4-3
Beeper Tone
Medium
4-4
Beeper Volume
High
4-5
Power Mode
Reduced
4-5
Beep After Good Decode
Enable
4-6
Picklist Mode
Disabled Always
4-7
Decode Session Timeout
3.0 seconds
4-8
Fuzzy 1D Decoding
Enable
4-8
Decode Mirror Images
Never
4-9
Connection Maintenance Interval
15 minutes
4-10
Radio Output Power
Bluetooth Class 1
4-12
Parameter Broadcast
Enable
4-12
Single Point/Multipoint Operation
Single Point
4-13
Page 57
User Preferences
4-3
User Preferences Set Default Parameter Scan this bar code to return all parameters to the default values listed in Table A-1 on page A-1.
Set All Defaults
Parameter Scanning To disable decoding of parameter bar codes, scan the Disable Parameter Scanning bar code below. Note that the digital scanner can still decode the Set Defaults parameter bar code. To enable decoding of parameter bar codes, either scan Enable Parameter Scanning or Set All Defaults.
*Enable Parameter Scanning
Disable Parameter Scanning
Page 58
4-4
Symbol DS3478 Product Reference Guide
Beeper Tone To select a decode beep frequency (tone), scan the Low Frequency, Medium Frequency, or High Frequency bar code.
Low Frequency
*Medium Frequency
High Frequency
Page 59
User Preferences
4-5
Beeper Volume To select a beeper volume, scan the Low Volume, Medium Volume, or High Volume bar code.
Low Volume
Medium Volume
*High Volume Power Mode This parameter determines whether or not the digital scanner enters reduced power mode after a decode attempt. When in reduced power mode, the digital scanner draws less current from its battery.
Continuous On
*Reduced Power Mode
Page 60
4-6
Symbol DS3478 Product Reference Guide
Beep After Good Decode Scan one of the following bar codes to select whether the digital scanner beeps after a good decode. If you select Do Not Beep After Good Decode, the beeper still operates during parameter menu scanning and indicates error conditions.
*Beep After Good Decode (Enable)
Do Not Beep After Good Decode (Disable)
Page 61
User Preferences
Picklist Mode Picklist mode enables the digital scanner to decode only bar codes that are aligned under the laser crosshair. Select one of the following picklist modes for the digital scanner:
• Disabled Always (default) - Picklist mode is always disabled. • Enabled Out of Scanstand - Picklist mode is enabled when the digital scanner is out of presentation (scanstand) mode and disabled when the digital scanner is in presentation mode.
• Enabled Always - Picklist mode is always enabled.
NOTE
If you enabled DPM Scanning on page 5-5, disable Picklist Mode when scanning a DPM bar code. Picklist performance is not guaranteed for DPM bar codes.
*Disabled Always
Enabled Out of Scanstand
Enabled Always
4-7
Page 62
4-8
Symbol DS3478 Product Reference Guide
Decode Session Timeout This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in 0.1 second increments from 0.5 to 9.9 seconds. The default timeout is 3.0 seconds. To set a Decode Session Timeout, scan the bar code below. Next, scan two numeric bar codes from Appendix D, Numeric Bar Codes that correspond to the desired on time. Enter a leading zero for single digit numbers. For example, to set a Decode Session Timeout of 0.5 seconds, scan the bar code below, then scan the 0 and 5 bar codes. To correct an error or change the selection, scan Cancel on page D-3.
Decode Session Timeout
Fuzzy 1D Decoding Enable this parameter to increase aggressiveness when decoding significantly damaged 1D symbols. Disabling this parameter reduces decode aggressiveness on such symbols, but increases decode aggressiveness on 2D symbols. NOTE
123Scan does not support this option.
*Enable Fuzzy 1D Decoding
Disable Fuzzy 1D Decoding
Page 63
User Preferences
Decode Mirror Images (Data Matrix Only) Select an option for decoding mirror image Data Matrix bar codes:
• Always - decode only Data Matrix bar codes that are mirror images • Never - do not decode Data Matrix bar codes that are mirror images • Auto - decode both mirrored and unmirrored Data Matrix bar codes.
*Never
Always
Auto
4-9
Page 64
4 - 10 Symbol DS3478 Product Reference Guide
Radio Communications Connection Maintenance Interval When a digital scanner disconnects from a cradle due to a Link Supervision Timeout, the digital scanner immediately attempts to reconnect to the cradle for 30 seconds. If the digital scanner does not reconnected within 30 seconds, it enters low power mode. Thereafter, when you scan a bar code, the digital scanner attempts to reconnect before transmitting the data. To guarantee that a disconnected digital scanner can reconnect when it comes back in range, the cradle reserves the connection for that digital scanner for a period of time defined by the Connection Maintenance Interval. If the cradle already supports the maximum four digital scanners, and one digital scanner disconnects, a fifth digital scanner cannot pair to the cradle during this interval. Connection Maintenance Interval options are:
• 15 minutes • 30 minutes • One hour • Two hours • Four hours • Eight hours • 24 hours • Indefinitely.
Considerations The system administrator determines the Connection Maintenance Interval. A shorter interval allows new users to gain access to abandoned connections more quickly, but causes problems if users leave the work area for extended periods. A longer interval allows existing users to leave the work area for longer periods of time, but ties up the system for new users. To avoid this conflict, users who are going off-shift can scan the unpair bar code on page 4-13 to ignore the Connection Maintenance Interval and make the connection immediately available. To set the Connection Maintenance Interval, select one of the following bar codes.
*Set Interval to 15 Minutes
Set Interval to 30 Minutes
Page 65
User Preferences 4 - 11
Connection Maintenance Interval (continued)
Set Interval to 60 Minutes
Set Interval to 2 Hours
Set Interval to 4 Hours
Set Interval to 8 Hours
Set Interval to 24 Hours
Set Interval to Forever
Page 66
4 - 12 Symbol DS3478 Product Reference Guide
Radio Output Power The Symbol DS3478 uses a Class 1 Bluetooth radio with a transmission range of up to 100m. Optionally place the radio in Class 2 operating mode to restrict the transmission range to 10m and reduce the effect of the radio on neighboring wireless systems. Scan a bar code to select Class 1 or Class 2 operation.
*Bluetooth Class 1
Bluetooth Class 2
Parameter Broadcast Enable Parameter Broadcast to broadcast all parameter bar codes scanned to all other digital scanners in the piconet. Disable this to process parameter bar codes by the individual digital scanner only, and the digital scanner ignores parameters broadcast from other digital scanners or from the cradle (e.g., parameters sent via 123Scan).
*Enable Parameter Broadcast
Disable Parameter Broadcast
Page 67
User Preferences 4 - 13
Single Point/Multipoint Operation The cradle supports communication from up to four digital scanners simultaneously. This multipoint mode requires an external power supply to charge the digital scanners in the cradle. To power the cradle from the interface cable (either from the USB hub or from a power supply attached to the interface cable), place the cradle in single point mode. In single point mode, only one digital scanner can connect to the cradle at a time. NOTE
When operating in bus-powered mode, the cradle must turn off the Bluetooth radio to charge the digital scanner. For this reason, only charge the digital scanner paired with the cradle in the cradle. Placing another digital scanner in the cradle for charging disrupts communication with the paired digital scanner. When setting options while in multipoint mode, allow time for the setting changes to apply to all digital scanners.
To select single point or multipoint mode, scan the appropriate bar code.
Multipoint Mode
*Single Point Mode
Unpair Scan the following bar code to disconnect the digital scanner from its cradle.
Unpairing
NOTE
The Symbol DS3478 Quick Start Guide also includes the unpairing bar code
Page 68
4 - 14 Symbol DS3478 Product Reference Guide