The text of a manual · part 44 of 50
Symbol DS3478 Smart Focus Digital Scanner Product Reference Guide: Standard Default Parameters
Pages 367 to 376 of 416, from Symbol DS3478 Smart Focus Digital Scanner Product Reference Guide
The original document is the PDF (9.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol DS-3478
Page 367
Appendix A Standard Default Parameters
Table A-1
Standard Default Parameters Table Parameter
Default
Page Number
User Preferences Set Default Parameter
All Defaults
4-3
Parameter Scanning
Enable
4-3
Beeper Tone
Medium
4-4
Beeper Volume
High
4-5
Power Mode
Reduced
4-5
Beep After Good Decode
Enable
4-6
Picklist Mode
Disabled Always
4-7
Decode Session Timeout
3.0 seconds
4-8
Fuzzy 1D Decoding
Enable
4-8
Decode Mirror Images
Never
4-9
Connection Maintenance Interval
15 minutes
4-10
Radio Output Power (Bluetooth)
Class 1
4-12
Parameter Broadcast
Enable
4-12
Single Point/Multipoint Operation
Single Point
4-13
Radio Communications
1
User selection is required to configure this interface and this is the most common selection.
Page 368
A-2
Symbol DS3478 Product Reference Guide
Table A-1
Standard Default Parameters Table (Continued) Parameter
Default
Page Number
Decoding Options Focus Mode
Far Focus
5-3
Decoding Illumination
Enable
5-4
Decode Aiming Pattern
Enable
5-4
DPM Scanning
Enable
5-5
Keyboard Wedge Host Type
IBM PC/AT& IBM PC Compatibles1
6-4
Keyboard Wedge Country Types (Country Codes)
North American
6-5
Ignore Unknown Characters
Enable
6-7
Keystroke Delay
0 msec (No Delay)
6-7
Intra-Keystroke Delay
Disable
6-8
Alternate Numeric Keypad Emulation
Disable
6-8
Caps Lock On
Disable
6-9
Caps Lock Override
Disable
6-9
Convert Wedge Data
Do Not Convert Wedge Data
6-10
Function Key Mapping
Disable
6-10
FN1 Substitution
Disable
6-11
Send Make and Break
Send Make and Break Scan Codes
6-11
RS-232 Host Types
Standard RS-2321
7-6
Baud Rate
9600
7-7
Parity
None
7-9
Check Receive Errors
Enable
7-10
Stop Bit Select
1 Stop Bit
7-10
Data Bits
8-Bit
7-11
Keyboard Wedge Host Parameters
RS-232 Host Parameters
1User selection is required to configure this interface and this is the most common selection.
Page 369
Standard Default Parameters
Table A-1
Standard Default Parameters Table (Continued) Parameter
Default
Page Number
Hardware Handshaking
None
7-11
Software Handshaking
None
7-13
Host Serial Response Time-out
Minimum: 2 Sec
7-15
RTS Line State
Host: Low RTS
7-16
Beep on <BEL>
Disable
7-16
Intercharacter Delay
Minimum: 0 msec
7-17
Nixdorf Mode A/B and OPOS/JPOS Beep/ LED Options
Normal Operation
7-18
Ignore Unknown Characters
Send Bar Code
7-19
USB Device Type
HID Keyboard Emulation
8-4
USB Country Keyboard Types (Country Codes)
North American
8-5
USB Keystroke Delay
No Delay (0 msec)
8-7
USB CAPS Lock Override
Disable
8-7
USB Ignore Unknown Characters
Enable
8-8
Emulate Keypad
Disable
8-8
USB Keyboard FN1 Substitution
Disable
8-9
Function Key Mapping
Disable
8-9
Simulated Caps Lock
Disable
8-10
Convert Case
No Case Conversion
8-10
Port Address
None Selected
9-4
Convert Unknown to Code 39
Disable
9-5
Wand Emulation Host Types
Symbol OmniLink Interface Controller1
10-4
Leading Margin
80 msec
10-5
Polarity
Bar High/Margin Low
10-6
USB Host Parameters
IBM 468X/469X Host Parameters
Wand Emulation Host Parameters
1
User selection is required to configure this interface and this is the most common selection.
A-3
Page 370
A-4
Symbol DS3478 Product Reference Guide
Table A-1
Standard Default Parameters Table (Continued) Parameter
Default
Page Number
Ignore Unknown Characters
Enable
10-6
Convert All to Code 39
Disable
10-7
Convert Code 39 to Full ASCII
Disable
10-8
Beep Style
Beep on Successful Transmit
11-4
Parameter Pass-Through
Parameter Process and Pass Through
11-5
Convert Newer Code Types
Convert Newer Code Types
11-6
Module Width
20 µs Module Width
11-7
Convert All Bar Codes to Code 39
Disable
11-7
Code 39 Full ASCII Conversion
Disable
11-8
Transmission Timeout
3 seconds
11-9
Ignore Unknown Characters
Send Bar Codes with Unknown Characters
11-10
Leading Margin
2 ms
11-11
Check for Decode LED
Check for Decode LED
11-12
None1
12-1
UPC-A
Enable
13-7
UPC-E
Enable
13-7
UPC-E1
Disable
13-8
EAN-13
Enable
13-8
EAN-8
Enable
13-9
Bookland EAN
Disable
13-9
Decode UPC/EAN Supplementals (2 and 5 digits)
Ignore Supplementals
13-10
Scanner Emulation Host Parameters
123Scan Configuration Tool 123Scan Configuration UPC/EAN
1User selection is required to configure this interface and this is the most common selection.
Page 371
Standard Default Parameters
Table A-1
Standard Default Parameters Table (Continued) Parameter
Default
User-Programmable Supplementals
Page Number 13-13
UPC/EAN Supplemental Redundancy
10
13-13
Transmit UPC-A Check Digit
Enable
13-14
Transmit UPC-E Check Digit
Enable
13-14
Transmit UPC-E1 Check Digit
Enable
13-15
UPC-A Preamble
System Character
13-16
UPC-E Preamble
System Character
13-17
UPC-E1 Preamble
System Character
13-18
Convert UPC-E to A
Disable
13-19
Convert UPC-E1 to A
Disable
13-19
EAN-8 Extend
Disable
13-20
Bookland ISBN Format
ISBN-10
13-21
UCC Coupon Extended Code
Disable
13-22
ISSN EAN
Disable
13-22
Code 128
Enable
13-23
Set Length(s) for Code 128
Any Length
13-23
GS1-128 (formerly UCC/EAN-128)
Enable
13-25
ISBT 128
Enable
13-25
ISBT Concatenation
Disable
13-26
Check ISBT Table
Enable
13-27
ISBT Concatenation Redundancy
10
13-27
Code 39
Enable
13-28
Trioptic Code 39
Disable
13-28
Convert Code 39 to Code 32
Disable
13-29
Code 32 Prefix
Disable
13-29
Set Length(s) for Code 39
2 to 55
13-30
Code 128
Code 39
1User selection is required to configure this interface and this is the most common selection.
A-5
Page 372
A-6
Symbol DS3478 Product Reference Guide
Table A-1
Standard Default Parameters Table (Continued) Parameter
Default
Page Number
Code 39 Check Digit Verification
Disable
13-32
Transmit Code 39 Check Digit
Disable
13-32
Code 39 Full ASCII Conversion
Disable
13-33
Buffer Code 39
Disable
13-34
Code 93
Disable
13-36
Set Lengths for Code 93
4 to 55
13-36
Code 11
Disable
13-38
Set Lengths for Code 11
4 to 55
13-38
Code 11 Check Digit Verification
Disable
13-40
Transmit Code 11 Check Digits
Disable
13-41
Interleaved 2 of 5 (I 2 of 5)
Enable
13-42
Set Lengths for Interleaved 2 of 5
14
13-42
I 2 of 5 Check Digit Verification
Disable
13-44
Transmit I 2 of 5 Check Digit
Disable
13-44
Convert I 2 of 5 to EAN-13
Disable
13-45
Discrete 2 of 5
Disable
13-46
Set Lengths for D 2 of 5
12
13-46
Codabar
Disable
13-48
Set Lengths for Codabar
5 to 55
13-48
CLSI Editing
Disable
13-50
NOTIS Editing
Disable
13-50
Code 93
Code 11
Interleaved 2 of 5 (I 2 of 5)
Discrete 2 of 5 (D 2 of 5)
Codabar (NW - 7)
1
User selection is required to configure this interface and this is the most common selection.
Page 373
Standard Default Parameters
Table A-1
Standard Default Parameters Table (Continued) Parameter
Default
Page Number
MSI MSI
Disable
13-51
Set Lengths for MSI
4 to 55
13-51
MSI Check Digits
One
13-53
Transmit MSI Check Digit(s)
Disable
13-53
MSI Check Digit Algorithm
Mod 10/Mod 10
13-54
Disable
13-54
Matrix 2 of 5
Disable
13-55
Matrix 2 of 5 Lengths
1 Length - 14
13-56
Matrix 2 of 5 Redundancy
Disable
13-57
Matrix 2 of 5 Check Digit
Disable
13-57
Transmit Matrix 2 of 5 Check Digit
Disable
13-58
Inverse 1D
Regular
13-58
US Postnet
Enable
13-59
US Planet
Enable
13-59
Transmit US Postal Check Digit
Enable
13-60
UK Postal
Enable
13-60
Transmit UK Postal Check Digit
Enable
13-61
Japan Postal
Enable
13-61
Australian Postal
Enable
13-62
Netherlands KIX Code
Enable
13-62
USPS 4CB/One Code/Intelligent Mail
Disable
13-63
UPU FICS Postal
Disable
13-63
Chinese 2 of 5 Chinese 2 of 5 Matrix 2 of 5
Postal Codes
1
User selection is required to configure this interface and this is the most common selection.
A-7
Page 374
A-8
Symbol DS3478 Product Reference Guide
Table A-1
Standard Default Parameters Table (Continued) Parameter
Default
Page Number
GS1 DataBar GS1 DataBar-14
Enable
13-64
GS1 DataBar Limited
Enable
13-64
GS1 DataBar Expanded
Enable
13-65
Convert GS1 DataBar to UPC/EAN
Disable
13-65
Composite CC-C
Disable
13-66
Composite CC-A/B
Disable
13-66
Composite TLC-39
Disable
13-67
UPC Composite Mode
Always Linked
13-67
GS1-128 Emulation Mode for UCC/EAN Composite Codes
Disable
13-68
PDF417
Enable
13-69
MicroPDF417
Disable
13-69
Code 128 Emulation
Disable
13-70
Data Matrix
Enable
13-71
Data Matrix Inverse
Regular
13-71
Maxicode
Enable
13-72
QR Code
Enable
13-73
QR Inverse
Regular
13-73
MicroQR
Enable
13-74
Aztec
Enable
13-75
Aztec Inverse
Enable
13-75
Redundancy Level
1
13-76
Security Levels
0
13-78
Intercharacter Gap Size
Normal
13-80
Composite
2D Symbologies
Symbology - Specific Security Levels
1
User selection is required to configure this interface and this is the most common selection.
Page 375
Standard Default Parameters
Table A-1
Standard Default Parameters Table (Continued) Parameter
Default
Page Number
Macro PDF Flush Macro PDF Buffer
13-81
Abort Macro PDF Entry
13-81
Miscellaneous Scanner Options Transmit Code ID Character
None
14-3
Prefix Value
7013 <CR><LF>
14-4
Suffix 1 Value Suffix 2 Value
7013 <CR><LF>
14-4
Scan Data Transmission Format
Data As Is
14-5
FN1 Substitution Values
Set FN1 Substitution Value
14-6
Transmit “No Read” Message
Disable No Read
14-7
Report Version 1
14-7
User selection is required to configure this interface and this is the most common selection.
A-9
Page 376
A - 10 Symbol DS3478 Product Reference Guide