Page 201
Symbologies 13 - 29
Convert Code 39 to Code 32 Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry. Scan the appropriate bar code below to enable or disable converting Code 39 to Code 32. NOTE
Code 39 must be enabled for this parameter to function.
Convert Code 39 to Code 32 (Enable)
*Do Not Convert Code 39 to Code 32 (Disable)
Code 32 Prefix Scan the appropriate bar code to enable or disable adding the prefix character “A” to all Code 32 bar codes. NOTE
Convert Code 39 to Code 32 must be enabled for this parameter to function.
Enable Code 32 Prefix
*Disable Code 32 Prefix
Page 202
13 - 30 Symbol DS3478 Product Reference Guide
Set Lengths for Code 39 The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 39 for any length, one or two discrete lengths, or lengths within a specific range. If Code 39 Full ASCII is enabled, Length Within a Range or Any Length are the preferred options. NOTE
When setting lengths for different bar code types, enter a leading zero for single digit numbers.
One Discrete Length - This option allows the digital scanner to decode only those Code 39 symbols containing a selected length. Use the numeric bar codes in Appendix D, Numeric Bar Codes to select the length. For example, to decode only Code 39 symbols with 14 characters, scan Code 39 - One Discrete Length, then scan 1 followed by 4. In case of an error, or to change the selection, scan Cancel on page D-3. Two Discrete Lengths - This option allows the digital scanner to decode only those Code 39 symbols containing either of two selected lengths. Use the numeric bar codes in Appendix D, Numeric Bar Codes to select lengths. For example, to decode only Code 39 symbols containing either 2 or 14 characters, select Code 39 - Two Discrete Lengths, then scan 0, 2, 1, and then 4. In case of an error, or to change the selection, scan Cancel on page D-3. Length Within Range - This option allows the digital scanner to decode a Code 39 symbol within a specific length range. Use the numeric bar codes in Appendix D, Numeric Bar Codes to select the length range. For example, to decode Code 39 symbols containing between 4 and 12 characters, first scan Code 39 - Length Within Range. Then scan 0, 4, 1, and 2 (enter a leading zero for single digit numbers). In case of an error, or to change the selection, scan Cancel on page D-3. Any Length - This option allows the digital scanner to decode Code 39 symbols containing any number of characters within the digital scanner’s capability.
Page 203
Symbologies 13 - 31
Set Lengths for Code 39 (continued)
Code 39 - One Discrete Length
Code 39 - Two Discrete Lengths
Code 39 - Length Within Range
Code 39 - Any Length
Page 204
13 - 32 Symbol DS3478 Product Reference Guide
Code 39 Check Digit Verification Enable this feature to check the integrity of all Code 39 symbols to verify that the data complies with a specified check digit algorithm. The digital scanner decodes only those Code 39 symbols that include a modulo 43 check digit. Enable this feature only if the Code 39 symbols contain a modulo 43 check digit.
Enable Code 39 Check Digit
*Disable Code 39 Check Digit Transmit Code 39 Check Digit Scan a bar code below to transmit Code 39 data with or without the check digit.
Transmit Code 39 Check Digit (Enable)
*Do Not Transmit Code 39 Check Digit (Disable)
NOTE
Code 39 Check Digit Verification must be enabled for this parameter to function.
Page 205
Symbologies 13 - 33
Code 39 Full ASCII Conversion Code 39 Full ASCII is a variant of Code 39 that pairs characters to encode the full ASCII character set. To enable or disable Code 39 Full ASCII, scan the appropriate bar code below. Mapping Code 39 characters to ASCII values is host dependent. For keyboard wedge host conversion, see Table 6-2 on page 6-14. For RS-232 host conversion, see Table 7-4 on page 7-20. For USB host conversion, see Table 8-2 on page 8-11.
Enable Code 39 Full ASCII
*Disable Code 39 Full ASCII
NOTE
You cannot enable Trioptic Code 39 and Code 39 Full ASCII simultaneously.
Page 206
13 - 34 Symbol DS3478 Product Reference Guide
Code 39 Buffering (Scan & Store) This feature allows the digital scanner to accumulate data from multiple Code 39 symbols. Select Buffer Code 39 to temporarily buffer all Code 39 symbols with a leading space as a first character for later transmission. The leading space is not buffered. Since this feature affects Code 39 only, for best performance configure the digital scanner to decode the Code 39 symbology only. Decoding a valid Code 39 symbol with no leading space transmits in sequence all buffered data in a first-in first-out format, plus the “triggering” symbol. See the following pages for further details. Select Do Not Buffer Code 39 to transmit all decoded Code 39 symbols immediately without storing in the buffer.
Buffer Code 39 (Enable)
*Do Not Buffer Code 39 (Disable) While there is data in the transmission buffer, you cannot select Do Not Buffer Code 39. The buffer holds 200 bytes of information. To disable Code 39 buffering when there is data in the transmission buffer, first force the buffer transmission (see Transmitting Buffer on page 13-35) or clear the buffer.
Buffering Data To buffer data, enable Code 39 buffering and read a Code 39 symbol with a space immediately following the start pattern.
• Unless the data overflows the transmission buffer, the digital scanner issues a low-high beep to indicate successful decode and buffering. For overflow conditions, see Overfilling Transmission Buffer.
• The digital scanner adds the decoded data excluding the leading space to the transmission buffer. • No transmission occurs.
Page 207
Symbologies 13 - 35
Clearing Transmission Buffer To clear the transmission buffer, scan the Clear Buffer bar code below, which contains only a start character, a dash (minus), and a stop character. The digital scanner issues a short high-low-high beep and erases the transmission buffer.
Clear Buffer
NOTE
Because the Clear Buffer bar code contains only the dash (minus) character, set the Code 39 length to include length 1 before scanning this bar code.
Transmitting Buffer There are two methods to transmit the Code 39 buffer:
• Scan the Transmit Buffer bar code, which includes only a start character, a plus (+), and a stop character. The digital scanner transmits and clears the buffer, and issues a low-high beep.
Transmit Buffer
• Scan a Code 39 bar code with a leading character other than a space. The digital scanner appends the new decode data to the buffered data, transmits and clears the buffer, and issues a low-high beep to signal that the buffer was transmitted. NOTE
Because the Transmit Buffer bar code contains only a plus (+) character, set the Code 39 length to include length 1 before scanning this bar code.
Overfilling Transmission Buffer The Code 39 buffer holds 200 characters. If the symbol just read overflows the transmission buffer, the digital scanner issues three long high beeps to indicate it rejected the symbol, and no transmission occurs. The data in the buffer is not affected.
Attempt to Transmit an Empty Buffer If the symbol just read was the Transmit Buffer symbol and the Code 39 buffer is empty, the digital scanner issues a short low-high-low beep to signal that the buffer is empty, and no transmission occurs. The buffer remains empty.
Page 208
13 - 36 Symbol DS3478 Product Reference Guide
Code 93 Enable/Disable Code 93 To enable or disable Code 93, scan the appropriate bar code below.
Enable Code 93
*Disable Code 93 Set Lengths for Code 93 The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 93 for any length, one or two discrete lengths, or lengths within a specific range. One Discrete Length - This option allows the digital scanner to decode only those Code 93 symbols containing a selected length. Use the numeric bar codes in Appendix D, Numeric Bar Codes to select the length. For example, to decode only Code 93 symbols with 14 characters, scan Code 93 - One Discrete Length, then scan 1 followed by 4. In case of an error, or to change the selection, scan Cancel on page D-3. Two Discrete Lengths - This option allows the digital scanner to decode only those Code 93 symbols containing either of two selected lengths. Use the numeric bar codes in Appendix D, Numeric Bar Codes to select lengths. For example, to decode only Code 93 symbols containing either 2 or 14 characters, select Code 93 - Two Discrete Lengths, then scan 0, 2, 1, and then 4. In case of an error, or to change the selection, scan Cancel on page D-3. Length Within Range - This option allows the digital scanner to decode a Code 93 symbol within a specific length range. Use the numeric bar codes in Appendix D, Numeric Bar Codes to select the length range. For example, to decode Code 93 symbols containing between 4 and 12 characters, first scan Code 93 - Length Within Range. Then scan 0, 4, 1, and 2 (insert a leading zero for single digit numbers). In case of an error, or to change the selection, scan Cancel on page D-3. Any Length - This option allows the digital scanner to decode Code 93 symbols containing any number of characters within the digital scanner’s capability.
Page 209
Symbologies 13 - 37
Set Lengths for Code 93 (continued)
Code 93 - One Discrete Length
Code 93 - Two Discrete Lengths
Code 93 - Length Within Range
Code 93 - Any Length
Page 210
13 - 38 Symbol DS3478 Product Reference Guide
Code 11 Code 11 To enable or disable Code 11, scan the appropriate bar code below.
Enable Code 11
*Disable Code 11 Set Lengths for Code 11 The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 11 for any length, one or two discrete lengths, or lengths within a specific range. One Discrete Length - This option allows the digital scanner to decode only those Code 11 symbols containing a selected length. Use the numeric bar codes in Appendix D, Numeric Bar Codes to select the length. For example, to decode only Code 11 symbols with 14 characters, scan Code 11 - One Discrete Length, then scan 1 followed by 4. In case of an error, or to change the selection, scan Cancel on page D-3. Two Discrete Lengths - This option allows the digital scanner to decode only those Code 11 symbols containing either of two selected lengths. Use the numeric bar codes in Appendix D, Numeric Bar Codes to select lengths. For example, to decode only Code 11 symbols containing either 2 or 14 characters, select Code 11 - Two Discrete Lengths, then scan 0, 2, 1, and then 4. In case of an error, or to change the selection, scan Cancel on page D-3. Length Within Range - This option allows the digital scanner to decode a Code 11 symbol within a specific length range. Use the numeric bar codes in Appendix D, Numeric Bar Codes to select the length range. For example, to decode Code 11 symbols containing between 4 and 12 characters, first scan Code 11 - Length Within Range. Then scan 0, 4, 1, and 2 (insert a leading zero for single digit numbers). In case of an error, or to change the selection, scan Cancel on page D-3. Any Length - This option allows the digital scanner to decode Code 11 symbols containing any number of characters within the digital scanner’s capability.