Page 123
Chapter 8 USB Interface Introduction This chapter provides instructions for programming the digital scanner to interface with a USB host. The digital scanner cradle connects directly to a USB host, or a powered USB hub. The USB host can power the cradle and recharge the digital scanner battery, but this charging method has limitations. See Using the Host to Supply Power on page 1-5. Throughout the programming bar code menus, asterisks (*) indicate default values.
* Indicates Default
*North American Standard USB Keyboard
Connecting a USB Interface USB Series A Connector
Interface Cable
Figure 8-1 USB Connection
Feature/Option
Page 124
8-2
Symbol DS3478 Product Reference Guide
The digital scanner cradle connects with USB-capable hosts including:
• Desktop PCs and notebooks • Apple™ iMacs, Power Mac G4s and G5s, iBooks (North America only), PowerBooks • IBM SurePOS terminals • Sun, IBM, and other network computers that support more than one keyboard. The following operating systems support the digital scanner through USB:
• Windows® 98, 2000, ME, XP • Mac OS 8.5 and above • IBM 4690 OS. The digital scanner cradle also interfaces with other USB hosts which support USB Human Interface Devices (HID). For more information on USB technology, hosts, and peripheral devices, visit http://www.symbol.com/usb. To connect the digital scanner cradle to a USB host: 1.
Attach the modular connector of the USB interface cable to the cable interface port on the digital scanner. See Connecting the Cradle on page 1-4.
2.
Plug the series A connector into the USB host or hub, or plug the Plus Power connector into an available port of the IBM SurePOS terminal.
3.
Ensure all connections are secure.
4.
Pair the digital scanner to the cradle by scanning the bar code on the cradle.
5.
Select the USB device type by scanning the appropriate bar code from USB Device Type on page 8-4.
6.
On first installation when using Windows, the software displays a prompt to select or install the Human Interface Device driver. To install this driver, provided by Windows, click Next through all the choices and click Finished on the last choice. The digital scanner powers up during this installation.
7.
To modify any other parameter options, scan the appropriate bar codes in this chapter.
8.
Connect an external power supply if required. NOTE
Interface cables vary depending on configuration. The connectors may be different from those illustrated in Figure 8-1, but the steps to connect the digital scanner cradle are the same. Disconnect the power supply before changing host cables or the digital scanner may not recognize the new host.
If problems occur, see Troubleshooting on page 3-2.
Page 125
USB Interface
USB Default Parameters Table 8-1 lists the defaults for USB host parameters. To change any option, scan the appropriate bar code(s) provided in the parameter descriptions section beginning on page 8-4. NOTE
See Appendix A, Standard Default Parameters for all user preference, host, symbology, and miscellaneous default parameters.
Table 8-1 USB Host Default Table
Parameter
Default
Page Number
USB Host Parameters USB Device Type
HID Keyboard Emulation
8-4
USB Country Keyboard Types (Country Codes)
North American
8-5
USB Keystroke Delay
No Delay (0 msec)
8-7
USB Caps Lock Override
Disable
8-7
USB Ignore Unknown Characters
Enable
8-8
Emulate Keypad
Disable
8-8
USB Keyboard FN1 Substitution
Disable
8-9
Function Key Mapping
Disable
8-9
Simulated Caps Lock
Disable
8-10
Convert Case
No Case Conversion
8-10
8-3
Page 126
8-4
Symbol DS3478 Product Reference Guide
USB Host Parameters USB Device Type Select the desired USB device type. NOTE
When changing USB device types, the digital scanner disconnects and reconnects as the cradle re-enumerates on the USB bus.
*HID Keyboard Emulation
IBM Table Top USB
IBM Hand-Held USB
Page 127
USB Interface
USB Country Keyboard Types (Country Codes) Scan the bar code corresponding to the keyboard type. This setting applies only to the USB HID Keyboard Emulation device. NOTE
When changing USB Country Keyboard Types, the digital scanner disconnects and reconnects as the cradle re-enumerates on the USB bus.
*North American Standard USB Keyboard
German Windows
French Windows
French Canadian Windows 95/98
French Canadian Windows 2000/XP
8-5
Page 128
8-6
Symbol DS3478 Product Reference Guide
USB Country Keyboard Types (Country Codes) (continued)
Spanish Windows
Italian Windows
Swedish Windows
UK English Windows
Japanese Windows (ASCII)
Brazilian-Portuguese Windows
Page 129
USB Interface
8-7
USB Keystroke Delay This parameter sets the delay, in milliseconds, between emulated keystrokes. Scan a bar code below to increase the delay when hosts require slower data transmission.
*No Delay (0 msec)
Medium Delay (20 msec)
Long Delay (40 msec)
USB Caps Lock Override This option applies only to the HID Keyboard Emulation device. Enable this to preserve the case of the data regardless of the state of the caps lock key. This setting is always enabled for the Japanese, Windows (ASCII) keyboard type and can not be disabled.
Override Caps Lock Key (Enable)
*Do Not Override Caps Lock Key (Disable)
Page 130
8-8
Symbol DS3478 Product Reference Guide
USB Ignore Unknown Characters Unknown characters are characters the host does not recognize. Select Send Bar Codes With Unknown Characters to send all bar code data except for unknown characters. The digital scanner issues no error beeps. Select Do Not Send Bar Codes With Unknown Characters to prevent sending bar codes containing at least one unknown character to the host. The digital scanner issues an error beep.
*Send Bar Codes with Unknown Characters (Enable)
Do Not Send Bar Codes with Unknown Characters (Disable)
Emulate Keypad Enable this to send all characters as ASCII sequences over the numeric keypad. For example ASCII A transmits as “ALT make” 0 6 5 “ALT Break.”
*Disable Keypad Emulation
Enable Keypad Emulation