Page 107
RS-232 Interface
7-9
Parity A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements.
• Select Odd parity to set the parity bit value to 0 or 1, based on data, to ensure that the coded character contains an odd number of 1 bits.
• Select Even parity to set the parity bit value to 0 or 1, based on data, to ensure that the coded character contains an even number of 1 bits.
• Select Mark parity and the parity bit is always 1. • Select Space parity and the parity bit is always 0. • Select None when no parity bit is required.
Odd
Even
Mark
Space
*None
Page 108
7 - 10 Symbol DS3478 Product Reference Guide
Check Receive Errors Select whether or not to check the parity, framing, and overrun of received characters. The parity value of received characters is verified against the parity parameter selected previously.
*Check For Received Errors (Enable)
Do Not Check For Received Errors (Disable)
Stop Bit Select The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. Select the number of stop bits (one or two) based on the number the receiving terminal is programmed to accommodate. Set the number of stop bits to match host device requirements.
*1 Stop Bit
2 Stop Bits
Page 109
RS-232 Interface 7 - 11
Data Bits This parameter allows the digital scanner to interface with devices requiring a 7-bit or 8-bit ASCII protocol.
7-Bit
*8-Bit Hardware Handshaking The data interface consists of an RS-232 port designed to operate either with or without the hardware handshaking lines Request to Send (RTS) and Clear to Send (CTS). Disable Standard RTS/CTS handshaking to transmit scan data as it becomes available. Enable Standard RTS/CTS handshaking to transmit scan data according to the following sequence:
• The digital scanner reads the CTS line for activity. If CTS is asserted, the digital scanner waits up to the Host Serial Response Time-out for the host to de-assert the CTS line. If the CTS line is still asserted after the Host Serial Response Time-out expires (default), the digital scanner sounds a transmit error and discards any scanned data.
• When the CTS line is de-asserted, the digital scanner asserts the RTS line and waits up to the Host Serial Response Time-out for the host to assert CTS. When the host asserts CTS, the digital scanner transmits data. If the CTS line is still de-asserted after Host Serial Response Time-out expires (default), the digital scanner sounds a transmission error and discards the data.
• When data transmission completes, the digital scanner de-asserts RTS 10 msec after sending the last character.
• The host responds by de-asserting CTS. The digital scanner checks for a de-asserted CTS upon the next data transmission. During data transmission, the CTS line should be asserted. If CTS is de-asserted for more than 50 ms between characters, the digital scanner aborts transmission, sounds a transmission error, and discards the data. If this communications sequence fails, the digital scanner issues an error indication and discards the data. Rescan the data. If hardware handshaking and software handshaking are both enabled, hardware handshaking takes precedence. NOTE
The DTR signal is jumpered (set) to the active state.
Page 110
7 - 12 Symbol DS3478 Product Reference Guide
Hardware Handshaking (continued) Scan a bar code to select one of the following hardware handshaking options:
• None - Scan the bar code below if no hardware handshaking is desired. • Standard RTS/CTS - Scan the bar code below to select Standard RTS/CTS hardware handshaking. • RTS/CTS Option 1 - The digital scanner asserts RTS before transmitting and ignores the state of CTS. The digital scanner de-asserts RTS when the transmission completes.
• RTS/CTS Option 2 - RTS is always high or low (user-programmed logic level). However, the digital scanner waits for CTS to be asserted before transmitting data. If CTS is not asserted within Host Serial Response Time-out (default), the digital scanner issues an error indication and discards the data.
• RTS/CTS Option 3 - The digital scanner asserts RTS before data transmission, regardless of the state of CTS. The digital scanner waits up to Host Serial Response Time-out (default) for CTS to be asserted. If CTS is not asserted during this time, the digital scanner issues an error indication and discards the data. The digital scanner de-asserts RTS when transmission completes.
*None
Standard RTS/CTS
RTS/CTS Option 1
RTS/CTS Option 2
RTS/CTS Option 3
Page 111
RS-232 Interface 7 - 13
Software Handshaking This parameter offers control of the data transmission process in addition to, or instead of, that offered by hardware handshaking. There are five options. If software handshaking and hardware handshaking are both enabled, hardware handshaking takes precedence.
None Select this option to transmit data immediately. No response is expected from the host.
ACK/NAK If you select this option, after transmitting data, the digital scanner expects either an ACK or NAK response from the host. When the scanner receives a NAK, it transmits the same data again and waits for either an ACK or NAK. After three unsuccessful attempts to send data after the scanner receives NAKs, the scanner issues an error indication and discards the data. The digital scanner waits up to the programmable Host Serial Response Time-out to receive an ACK or NAK. If the digital scanner does not get a response in this time, it issues an error indication and discards the data. There are no retries when a time-out occurs.
ENQ If you select this option, the digital scanner waits for an ENQ character from the host before transmitting data. If it does not receive an ENQ within the Host Serial Response Time-out, the digital scanner issues an error indication and discards the data. The host must transmit an ENQ character at least every Host Serial Response Time-out to prevent transmission errors.
ACK/NAK with ENQ This combines the two previous options. For re-transmissions of data, due to a NAK from the host, an additional ENQ is not required.
XON/XOFF An XOFF character turns the digital scanner transmission off until the digital scanner receives an XON character. There are two situations for XON/XOFF:
• The digital scanner receives an XOFF before it has data to send. When the digital scanner has data to send, it waits up to Host Serial Response Time-out for an XON character before transmission. If it does not receive the XON within this time, the digital scanner issues an error indication and discards the data.
• The digital scanner receives an XOFF during a transmission. Data transmission then stops after sending the current byte. When the digital scanner receives an XON character, it sends the rest of the data message. The digital scanner waits up to 30 seconds for the XON.
Page 112
7 - 14 Symbol DS3478 Product Reference Guide
Software Handshaking (continued)
*None
ACK/NAK
ENQ
ACK/NAK with ENQ
XON/XOFF
Page 113
RS-232 Interface 7 - 15
Host Serial Response Time-out This parameter specifies how long the digital scanner waits for an ACK, NAK, or CTS before determining that a transmission error occurred. This only applies when in one of the ACK/NAK software handshaking modes, or RTS/CTS hardware handshaking mode. NOTE
This parameter does not apply to the Wincor-Nixdorf RS-232 Mode A/B and the OPOS/JPOS host types.
*Minimum: 2 sec
Low: 2.5 Sec
Medium: 5 Sec
High: 7.5 Sec
Maximum: 9.9 Sec
Page 114
7 - 16 Symbol DS3478 Product Reference Guide
RTS Line State This parameter sets the idle state of the Serial Host RTS line. Scan a bar code below to select the Low RTS or High RTS line state.
*Host: Low RTS
Host: High RTS
Beep on <BEL> Single Point Mode Only If you enable this parameter, the digital scanner issues a beep when it detects a <BEL> character on the RS-232 serial line. <BEL> indicates an illegal entry or other important event. NOTE
This parameter is not supported in Multipoint mode.
Beep On <BEL> Character (Enable)
*Do Not Beep On <BEL> Character (Disable)