The text of a manual · part 11 of 50
Symbol DS3478 Smart Focus Digital Scanner Product Reference Guide: Keyboard Wedge Interface, pages 75 to 82
Pages 75 to 82 of 416, from Symbol DS3478 Smart Focus Digital Scanner Product Reference Guide
The original document is the PDF (9.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol DS-3478
Page 75
Chapter 6 Keyboard Wedge Interface Introduction This chapter provides instructions for programming the digital scanner for the keyboard wedge host interface, used to connect the digital scanner between the keyboard and host computer. The digital scanner translates the bar code data into keystrokes, and transmits the information to the host computer via the cradle interface. The host computer accepts the keystrokes as if they originated from the keyboard. This interface adds bar code reading functionality to a system designed for manual keyboard input. In this mode the keyboard keystrokes are simply passed through. Throughout the programming bar code menus, asterisks (*) indicate default values.
* Indicates Default
*North American
Feature/Option
Page 76
6-2
Symbol DS3478 Product Reference Guide
Connecting a Keyboard Wedge Interface Male DIN Host Connector
Power Connector
Keyboard Connector
Female DIN Keyboard Connector
Y-Cable
Figure 6-1 Keyboard Wedge Interface Connection with Y-cable
To connect the keyboard wedge interface Y-cable: 1.
Turn off the host computer and unplug the keyboard connector.
2.
Attach the modular connector of the Y-cable to the cable interface port on the digital scanner cradle. See Connecting the Cradle on page 1-4.
3.
Connect the round male DIN host connector of the Y-cable to the keyboard port on the host computer.
4.
Connect the round female DIN keyboard connector of the Y-cable to the keyboard connector.
5.
If required, attach the optional power supply to the power connector on the Y-cable.
6.
Ensure all connections are secure.
7.
Turn on the host system.
8.
Pair the digital scanner to the cradle by scanning the bar code on the cradle.
9.
Select the keyboard wedge host type by scanning the appropriate bar code from Keyboard Wedge Host Types on page 6-4.
10. To modify any other parameter options, scan the appropriate bar codes in this chapter. 11. Connect an external power supply if required. NOTE
Interface cables vary depending on configuration. The connectors may be different from those illustrated in Figure 6-1, but the steps to connect the digital scanner cradle are the same. Disconnect the power supply before changing host cables or the digital scanner may not recognize the new host.
Page 77
Keyboard Wedge Interface
6-3
Keyboard Wedge Default Parameters Table 6-1 lists the defaults for keyboard wedge host parameters. To change any option, scan the appropriate bar code(s) provided in this chapter. NOTE
See Appendix A, Standard Default Parameters for all user preference, host, symbology, and miscellaneous default parameters.
Table 6-1 Keyboard Wedge Host Default Table
Parameter
Default
Page Number
Keyboard Wedge Host Parameters Keyboard Wedge Host Type
IBM PC/AT& IBM PC Compatibles
6-4
Keyboard Wedge Country Types (Country Codes)
North American
6-5
Ignore Unknown Characters
Enable
6-7
Keystroke Delay
0 msec (No Delay)
6-7
Intra-Keystroke Delay
Disable
6-8
Alternate Numeric Keypad Emulation
Disable
6-8
Caps Lock On
Disable
6-9
Caps Lock Override
Disable
6-9
Convert Wedge Data
Do Not Convert Wedge Data
6-10
Function Key Mapping
Disable
6-10
FN1 Substitution
Disable
6-11
Send Make and Break
Send Make and Break Scan Codes
6-11
Page 78
6-4
Symbol DS3478 Product Reference Guide
Keyboard Wedge Parameters Keyboard Wedge Host Types Select the keyboard wedge host by scanning one of the following bar codes.
*IBM PC/AT & IBM PC Compatibles
IBM AT Notebook
NCR 7052
Page 79
Keyboard Wedge Interface
Keyboard Wedge Country Types (Country Codes) Scan the bar code corresponding to the keyboard type. If your keyboard type does not appear, see Alternate Numeric Keypad Emulation on page 6-8.
*North American
German Windows
French Windows
French Canadian Windows 95/98
French Canadian Windows XP/2000
Spanish Windows
6-5
Page 80
6-6
Symbol DS3478 Product Reference Guide
Keyboard Wedge Country Types (Country Codes) (continued)
Italian Windows
Swedish Windows
UK English Windows
Japanese Windows
Brazilian-Portuguese Windows
Page 81
Keyboard Wedge Interface
6-7
Ignore Unknown Characters Unknown characters are characters the host does not recognize. Select Send Bar Codes With Unknown Characters to send all bar code data except for unknown characters. The digital scanner emits no error beeps. Select Do Not Send Bar Codes With Unknown Characters to send bar code data until the scanner encounters the first unknown character. The digital scanner emits an error beep.
*Send Bar Codes with Unknown Characters (Enable)
Do Not Send Bar Codes with Unknown Characters (Disable)
Keystroke Delay This is the delay in milliseconds between emulated keystrokes. Scan a bar code below to increase the delay when hosts require a slower data transmission.
*0 msec (No Delay)
20 msec (Medium Delay)
40 msec (Long Delay)
Page 82
6-8
Symbol DS3478 Product Reference Guide
Intra-Keystroke Delay Enable Intra-Keystroke Delay to insert an additional delay between each emulated key press and release. This also sets the Keystroke Delay parameter to a minimum of 5 msec.
Enable Intra-Keystroke Delay
*Disable Intra-Keystroke Delay
Alternate Numeric Keypad Emulation This allows emulation of most other country keyboard types not listed in Keyboard Wedge Country Types (Country Codes) on page 6-5 in a Microsoft® operating system environment.
Enable Alternate Numeric Keypad
*Disable Alternate Numeric Keypad