Page 9
Writing with the CyberPen To use the writing instrument, hold the tip (writing end) of the pen and twist the body, until the full pen tip is exposed.
Pen Refill Removal and Insertion The pen refill cartridge comes equipped with a removal tool. There is a groove in the removal tool to “grab” the refill and pull it out. To remove the ink cartridge: 1.
Twist the bottom of the pen to expose the ink cartridge.
2.
Insert the ink end of the pen into the removal tool on the refill cartridge and pull the cartridge out as shown:
Note: The pen refill can be reordered by contacting the AT Cross Consumer Relations Department at 1-800-510-9660. The part number for the fine point black ink refill is 8669M2. The part number for the broad point black ink refill is 8671M2. 7
Page 10
Pen Refill To insert a new ink cartridge, insert the ink end of the pen into the pen as shown:
groove
8
Page 11
Parameter Bar Codes The following bar code parameter menus can be used to program the scanner.
Clear Bar Codes The following bar code clears the bar code data collected and currently stored in the pen.
Clear Bar Codes
Set Defaults This parameter resets the pen to the default values for all parameters.
Set Defaults
9
Page 12
Good Decode LED On Time This is the duration the Green LED remains on following a good decode.
.25sec
.5 sec
.75 sec. (default)
1.0 sec
10
Page 13
Volume This parameter is used to change the beeper volume on the pen. Alternatively, beeper volume can be changed by doubleclicking the scan button on the pen.
Quiet/Off
Low Volume
Medium Volume
High Volume (default)
11
Page 14
Continuous Scan Enable/Disable When enabled, this parameter allows you to scan multiple bar codes with one press and hold of the scan button. When disabled, the scan button must be pressed each time to initiate a scan.
Continuous Scan Enabled (default)
Continuous Scan Disabled
12
Page 15
Regulatory Information This device has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the Federal Communications Commissions Rules and Regulation. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. However, there is no guarantee that interference will not occur in a particular installation. If the equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • • •
Re-orient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help
Caution: Changes or modifications not expressly approved by Symbol Technologies Inc, could void your authority to operate this equipment. Radio Frequency Interference Requirements - Canada This Class B digital apparatus meets the requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la Classe B respecte toutes les exigences du Reglement sur le Materiél Brouilleur du Canada. CE Marking and European Union Compliance Products intended for sale within the European Union are marked with the CE Mark which indicates compliance to applicable Directives and European Normes (EN), as follows. Amendments to these Directives or ENs are included: Applicable Directives: • •
Electromagnetic Compatibility Directive 89/336/EEC Low Voltage Directive 73/23/EEC
13
Page 16
Applicable Standards: •
EN 55 022 - Limits and Methods of Measurement of Radio Interference Characteristics of Information technology Equipment • EN 50 082-1 - Electromagnetic Compatibility - Generic Immunity Standard, Part 1: Residential, commercial, Light Industry • IEC 801.2 - Electromagnetic Compatibility for Industrial Process Measurement and Control Equipment Part 2: Electrostatic Discharge Requirements • IEC 801.3 - Electromagnetic Compatibility for Industrial Process Measurement and Control Equipment Part 3: Radiated Electromagnetic Field Requirements • IEC 801.4 - Electromagnetic Compatibility for Industrial Process Measurement and Control Equipment Part 4: Electrical Fast Transients Requirements EN 60 950 + Amd 1 + Amd 2 - Safety of Information Technology Equipment Including Electrical Business Equipment
70-33480-02 Rev. B June 1999