Page 11

Q u i c k

R e f e r e n c e

Inter-Connecting Cradles Up to four 4-slot CRD1700-4000S serial cradles may be interconnected (daisy-chained) with the CRD1700-4000E using an RJ-45/ 10 to RJ-45/10 inter-cradle cable (p/n 70349-001). This cable is required for each cradle to be connected. WARNING Each cradle must have its own power supply. Any other method of power hookup is unsafe. To inter-connect cradles: 1. Connect the power supply to the second 4-slot cradle as described in the Connecting Power section. Note: You must use a 8V. 5A. power supply on the serial cradle being connected to the ethernet cradle. 2. Plug one end of the inter-cradle cable into the modular jack labeled EXP on the back of the first cradle. The Expansion Connector is the modular jack located furthest from the Power Connector, as shown in the following illustration. 3. Plug the other end of the inter-cradle cable into the modular jack labeled Host on the back of the second serial cradle. The Host Connector is located between the Power Connector and the Expansion Connector, as shown in the following illustration.

4. Repeat the previous steps for any additional 4-slot serial cradles you want to connect. Serial Cradle

Ethernet Cradle

Inter-Cradle Cable

9

Page 12

C R D 1 7 0 0 - 4 0 0 0 E E t h e r n e t C r a d l e

Software Configuration The CRD1700-4000E appears to SPT 1700 terminals inserted into the cradle as a direct-connect PPP service. Therefore, just as you would set up a Palm III terminal to connect to an Internet Service Provider (ISP) like Compuserve or Earthlink, the SPT 1700 terminals must be configured for use with the cradle. This section describes the steps necessary to configure the SPT 1700 terminal.

Configuring NetSync Options NetSync must be configured for use with the CRD1700-4000E. From the HotSync panel on your SPT 1700, select each of the option panels available from the “Options” menu (accessed by tapping the Menu icon) and configure them as follows: 1. To configure the Modem Sync Preferences: a. Select the HotSync application from the main application screen. b. Select the menu icon to display the options menu. c. Select Modem Sync Prefs. d. Select “Network” and tap “OK”. 2. To configure the Primary PC host Setup: Note: This panel is very important! It tells the SPT 1700 terminal which machine to synchronize with on the network. a. Select HotSync from the main application screen. b. Select the menu icon to display the options menu. c. Select Primary PC host Setup. d. Using the PC you will synchronize with most often, right click on the HotSync Manager in the Windows tray on the host PC. Left click on Setup, click on the Network tab and then click on the TCP/IP Settings button. Copy down the Primary PC Name, Primary PC address, and the Subnet mask, and enter that information manually on your SPT 1700. Note: If the Subnet Mask box on your PC is empty, you do not need to enter anything in that section on your SPT 1700. Also, Network HotSync setup must be run on this PC be-

10

Page 13

Q u i c k

R e f e r e n c e fore the Network tab will be available. 3. To configure the Conduit Setup: a. Select the HotSync application from the main application screen. b. Select the menu icon to display the options menu. c. Select Conduit Setup. d. Check any items that you want synchronized and uncheck any items that you don’t want synchronized. Then tap “OK.” 4. To configure the Connection Setup: a. Select the HotSync application from the main application screen. b. Select the menu icon to display the options menu. c. Choose the Name: Direct Serial. d. Choose Port: Cradle. e. Choose Speed: 57,600 bps. f. Choose Flow Ctl: Automatic, Direct g. Tap “Done.”

Creating a CRD1700-4000E Modem Sync Service The SPT 1700 terminal communicates with the CRD1700-4000E via a Modem Sync. The Modem Sync offers many options which must be configured for use with the CRD1700-4000E. Create a separate CRD1700-4000E network configuration and select it as your default Modem Sync service. Use either Graffiti or the keyboard feature (click in the lower left-hand corner of the scratch pad on the abc to access the keyboard) to enter the following information: 1. Select the HotSync application from the main application screen. 2. Choose the Select Service box under the Modem Sync icon to create a new CRD1700-4000E service. 3. Select the Earthlink service, Click Menu->Duplicate. 4. Change the service name to CRD1700-4000E. Leave the user name and password blank. Choose the Direct Serial Connection option.

11

Page 14

C R D 1 7 0 0 - 4 0 0 0 E E t h e r n e t C r a d l e

Configuring the Remote Host PC The remote PC you wish to HotSync the SPT 1700 to must be set up for Network HotSync and configured to run from the network. 1. Make sure HotSync Manager is installed and running. 2. From the HotSync Manager, make sure Network is checked. If you don’t want HotSync Manager to use a serial port, make sure Local is unchecked. Note: The PC must be configured for proper TCP/IP network operation.

The HotSync Process Once the CRD1700-4000E is properly connected, data communication between an SPT 1700 terminal and the host computer can take place. When a terminal is inserted in the cradle, the cradle detects its presence and attempts to initiate the process on the terminal. All local slots in the cradle operate simultaneously; the procedure starts immediately when any terminal is inserted into a local slot. As stated earlier, if multiple slots are to be HotSync’d simultaneously, each must communicate with a different host PC. If the application requires simultaneous connection to a single host database, additional software, available from Symbol, is required. Terminals inserted into daisy-chained cradles are HotSynced in a roundrobin fashion simultaneously with any HotSyncs from local slots. Daisy-chained cradles share a logical “fifth slot” on the CRD17004000E, which, while it shares equal priority with the local slots, allows only one HotSync at a time.

12

Page 15

Q u i c k

R e f e r e n c e

Performing HotSync To initiate communication between the terminal and the host, gently insert the SPT 1700 terminal into a local cradle slot, or a slot on an inter-connected serial cradle. Do not force. When properly inserted, the slot’s LED turns red, then changes to flashing green, indicating that the host and the terminal are communicating. Removing the terminal from the cradle while the LED is flashing green will result in a disruption of communication and data may be lost.If the terminal is inserted into an inter-connected serial cradle slot while another terminal on the serial cradle chain is communicating with a host, the terminal waits (its LED remains red) until the first terminal finishes communicating. After the communication session completes, the slot’s LED turns solid green and remains green until the terminal is removed from the slot. To remove the terminal, pull it straight up from the slot.

Battery Charging The CRD1700-4000E can also be used to recharge the battery in the SPT 1700 Series terminal. All four slots can be used to simultaneously recharge the batteries on four terminals. To charge the battery, insert the terminal(s) in the slot(s). The battery begins to charge. It takes approximately 2 hours to recharge the battery. After two hours, remove the terminal from the cradle and power it on. The battery charge indicator should appear to be full. To verify that the terminal’s battery is charging while seated in the cradle: 1. Power the terminal on. 2. Tap the icon. 3. Centered on the top of the screen, an indicator displays in the shape of a lightening bolt. This indicates that the battery is charging.

13

Page 16

C R D 1 7 0 0 - 4 0 0 0 E E t h e r n e t C r a d l e

Indicator Lights Light

Indication

Off

No terminal is present in the slot.

Solid Red

Terminal is present, but communication has not started.

Green Flashing

Terminal is in the cradle, and communicating with the host computer.

Slow Red Flashing

Error, communication did not start.

Fast Red Flashing

Error, terminal inactivity timeout. The terminal did not finish HotSyncing in 15 minutes.

Solid Green

Terminal is present in the slot, communication is complete.

All LEDs Red Flashing

Automatic configuration of the cradle via the local DHCP service failed. Connect a properly configured DHCP server or DHCP relay agent to the subnet, and power cycle the CRD1700-4000E, or wait 10 minutes for a DHCP configuration retry. Or: Ethernet link is down. Make sure the ethernet cable is connected to an active hub.

Troubleshooting Symptom

Cause

Suggested Action

LEDs do not light when the cradle is powered on.

Cradle is not receiving power.

Make sure the power supply is securely connected and receiving power.

LED does not light when the terminal is inserted.

Terminal is not seated firmly in the cradle, or the battery is not properly installed in the terminal.

Make sure the battery is properly installed in the terminal, and reseat the terminal in the cradle.

Attempt by the cradle to HotSync the terminal failed.

Terminal was removed from the cradle while the LED was blinking green.

Replace the terminal in the cradle. This allows the cradle to attempt another HotSync.

Active Error dialog box on terminal.

Error dialog box must be cleared on the terminal. Use the stylus to press “OK” on the terminal’s touchscreen.

14

Page 17

Q u i c k

R e f e r e n c e

Symptom

Cause

Suggested Action

The cradle’s LEDs are flashing red.

The unit could not configure itself, or it has lost its lease on its IP address.

Connect the unit to an Ethernet network with a correctly functioning DHCP server.

Overcurrent condition on power supply.

Faulty cradle or terminal.

Remove floor power supply input A/C voltage for 30 seconds, then reapply power to establish the proper power supply output voltage.

Regulatory Information Radio Frequency Interference Requirements This device has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the Federal Communications Commissions Rules and Regulation. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. However, there is no guarantee that interference will not occur in a particular installation. If the equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Re-orient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help.

Radio Frequency Interference Requirements - Canada This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la Classe A est conforme à la norme NMB-003 du Canada.

CE Marking and European Union Compliance Products intended for sale within the European Union are marked with the CE Mark which indicates compliance to applicable Directives and European Normes (EN), as follows. Amendments to these Directives or ENs are included:

Applicable Directives • Electromagnetic Compatibility Directive 89/336/EEC • Low Voltage Directive 73/23/EEC

15

Page 18

C R D 1 7 0 0 - 4 0 0 0 E E t h e r n e t C r a d l e Applicable Standards • EN 55 022 - Limits and Methods of Measurement of Radio Interference Characteristics of Information technology Equipment • EN 55024:1998; Information technology equipment-Immunity characteristics-Limits and methods of measurement. • IEC 1000-4-2(1995-01) - Electromagnetic compatibility (EMC) - Part 4:Testing and measurement techniques - Section 2: Electrostatic discharge immunity test. • IEC 1000-4-3(1995-03) - Electromagnetic compatibility (EMC) - Part 4:Testing and measurement techniques - Section 3: Radiated, radio-frequency, electromagnetic field immunity test. • IEC 1000-4-4(1995-01) - Electromagnetic compatibility (EMC) - Part 4:Testing and measurement techniques - Section 4: Electrical Fast transient/burst immunity test. • IEC 1000-4-5:1995/EN61000-4-5:1995, Electromagnetic compatibility (EMC), Part 4:Testing and Measurement techniques;Section 5: Surge Immunity. • IEC 1000-4-6:1996/EN61000-4-6:1996, Electromagnetic compatibility (EMC), Part 4: Testing and Measurement techniques; Section 6: Immunity to conducted disturbances, induced by radio frequency fields. • IEC 1000-4-11: 1994/EN61000-4-11:1994, Electromagnetic compatibility (EMC), Part 4: Testing and measurement techniques; Section 11: Voltage Dips, Short Interruptions and Voltage Variations. • EN 60 950 + Amd 1 + Amd 2 - Safety of Information Technology Equipment Including Electrical Business Equipment • EN 60 825-1 (EN 60 825) - Safety of Devices Containing Lasers

16

Page 19

Q u i c k

R e f e r e n c e

Warranty Symbol Technologies, Inc. (“Symbol”) manufactures its hardware products in accordance with industry-standard practices. Symbol warrants that for a period of twelve (12) months from date of shipment, products will be free from defects in materials and workmanship. This warranty is provided to the original owner only and is not transferable to any third party. It shall not apply to any product (i) which has been repaired or altered unless done or approved by Symbol, (ii) which has not been maintained in accordance with any operating or handling instructions supplied by Symbol, (iii) which has been subjected to unusual physical or electrical stress, misuse, abuse, power shortage, negligence or accident or (iv) which has been used other than in accordance with the product operating and handling instructions. Preventive maintenance is the responsibility of customer and is not covered under this warranty. Wear items and accessories having a Symbol serial number, will carry a 90-day limited warranty. Nonserialized items will carry a 30-day limited warranty.

Warranty Coverage and Procedure During the warranty period, Symbol will repair or replace defective products returned to Symbol’s manufacturing plant in the US. For warranty service in North America, call the Symbol Support Center at 1-800-653-5350. International customers should contact the local Symbol office or support center. If warranty service is required, Symbol will issue a Return Material Authorization Number. Products must be shipped in the original or comparable packaging, shipping and insurance charges prepaid. Symbol will ship the repaired or replacement product freight and insurance prepaid in North America. Shipments from the US or other locations will be made F.O.B. Symbol’s manufacturing plant. Symbol will use new or refurbished parts at its discretion and will own all parts removed from repaired products. Customer will pay for the replacement product in case it does not return the replaced product to Symbol within 3 days of receipt of the replacement product. The process for return and customer’s charges will be in accordance with Symbol’s Exchange Policy in effect at the time of the exchange. Customer accepts full responsibility for its software and data including the appropriate backup thereof. Repair or replacement of a product during warranty will not extend the original warranty term. Symbol’s Customer Service organization offers an array of service plans, such as on-site, depot, or phone support, that can be implemented to meet customer’s special operational requirements and are available at a substantial discount during warranty period.

General Except for the warranties stated above, Symbol disclaims all warranties, express or implied, on products furnished hereunder, including without limitation implied warranties of merchantability and fitness for a particular purpose. The stated express warranties are in lieu of all obligations or liabilities on part of Symbol for damages, including without limitation, special, indirect, or consequential damages arising out of or in connection with the use or performance of the product. Seller’s liability for damages to buyer or others resulting from the use of any product, shall in no way exceed the purchase price of said product, except in instances of injury to persons or property. Some states (or jurisdictions) do not allow the exclusion or limitation of incidental or consequential damages, so the proceeding exclusion or limitation may not apply to you.

17

Page 20

Service Information Before you use the unit, it must be configured to operate in your facility’s network and run your applications. If you have a problem running your unit or using your equipment, contact your facility’s Technical or Systems Support. If there is a problem with the equipment, they will contact the Symbol Support Center: United States

1-800-653-5350

Canada

905-629-7226

United Kingdom

0800 328 2424

Asia/Pacific

337-6588

Australia

1-800-672-906

Austria

1-505-5794

Denmark

7020-1718

Finland

9 5407 580

France

01-40-96-52-21

Germany

6074-49020

Italy

2-484441

Mexico

5-520-1835

Netherlands

315-271700

Norway

66810600

South Africa

11-4405668

Spain

9-1-320-39-09

Sweden

84452900

Latin America Sales Support

1-800-347-0178 Inside US +1-561-483-1275 Outside US

Europe/Mid-East Distributor Operations Contact local distributor or call +44 208 945 7360

72-39472-01 Revision B, August 2000 Symbol Technologies, Inc. One Symbol Plaza Holtsville, NY 11742-1300