Page 1

E

C t

R h

D e

1 r

7 n

0 e

0 t

-

4 C

0 r

0 a

0 d

E l e

Page 2

C R D 1 7 0 0 - 4 0 0 0 E E t h e r n e t C r a d l e 2000 SYMBOL TECHNOLOGIES, INC. All rights reserved. Symbol reserves the right to make changes to any product to improve reliability, function, or design. Symbol does not assume any product liability arising out of, or in connection with, the application or use of any product, circuit, or application described herein. No license is granted, either expressly or by implication, estoppel, or otherwise under any patent right or patent, covering or relating to any combination, system, apparatus, machine, material, method, or process in which Symbol products might be used. An implied license only exists for equipment, circuits, and subsystems contained in Symbol products. Symbol and the Symbol logo are registered trademarks of Symbol Technologies, Inc. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. Symbol Technologies, Inc. One Symbol Plaza Holtsville, N.Y. 11742-1300 http://www.symbol.com Patents This product is covered by one or more of the following U.S. and foreign Patents: U.S. Patent No. 4,460,120; 4,496,831; 4,593,186; 4,603,262; 4,607,156; 4,652,750; 4,673,805; 4,736,095; 4,758,717; 4,816,660; 4,845,350; 4,896,026; 4,897,532; 4,923,281; 4,933,538; 4,992,717; 5,015,833; 5,017,765; 5,021,641; 5,029,183; 5,047,617; 5,103,461; 5,113,445; 5,130,520; 5,140,144; 5,142,550; 5,149,950; 5,157,687; 5,168,148; 5,168,149; 5,180,904; 5,216,232; 5,229,591; 5,230,088; 5,235,167; 5,243,655; 5,247,162; 5,250,791; 5,250,792; 5,260,553; 5,262,627; 5,262,628; 5,266,787; 5,278,398; 5,280,162; 5,280,163; 5,280,164; 5,280,498; 5,304,786; 5,304,788; 5,306,900; 5,321,246; 5,324,924; 5,337,361; 5,367,151; 5,373,148; 5,378,882; 5,396,053; 5,396,055; 5,399,846; 5,408,081; 5,410,139; 5,410,140; 5,412,198; 5,418,812; 5,420,411; 5,436,440; 5,444,231; 5,449,891; 5,449,893; 5,468,949; 5,471,042; 5,478,998; 5,479,000; 5,479,002; 5,479,441; 5,504,322; 5,519,577; 5,528,621; 5,532,469; 5,543,610; 5,545,889; 5,552,592; 5,557,093; 5,578,810; 5,581,070; 5,589,679; 5,589,680; 5,608,202; 5,612,531; 5,619,028; 5,627,359; 5,637,852; 5,664,229; 5,668,803; 5,675,139; 5,693,929; 5,698,835; 5,705,800; 5,714,746; 5,723,851; 5,734,152; 5,734,153; 5,742,043; 5,745,794; 5,754,587; 5,762,516; 5,763,863; 5,767,500; 5,789,728; 5,789,731; 5,808,287; 5,811,785; 5,811,787; 5,815,811; 5,821,519; 5,821,520; 5,823,812; 5,828,050; 5,850,078; 5,861,615; 5,874,720; 5,875,415; 5,900,617; 5,902,989; 5,907,146; 5,912,450; 5,914,478; 5,917,173; 5,920,059; 5,923,025; 5,929,420; 5,945,658; 5,945,659; 5,946,194; 5,959,285; 6,002,918; 6,021,947; 6,047,892; 6,050,491; 6,053,413; 6,056,200; 6,065,678; 6,067,297; 6,068,190; D305,885; D341,584; D344,501; D359,483; D362,453; D363,700; D363,918; D370,478; D383,124; D391,250; D405,077; D406,581; D414,171; D414,172, D419,548; D423,468; D424,035. Invention No. 55,358; 62,539; 69,060; 69,187 (Taiwan); No. 1,601,796; 1,907,875; 1,955,269 (Japan). European Patent 367,299; 414,281; 367,300; 367,298; UK 2,072,832; France 81/03938; Italy 1,138,713. rev. 06/00

Page 3

Q u i c k

R e f e r e n c e

Introduction The CRD1700-4000E 4-slot Ethernet cradle enables up to 4 SPT 1700 terminals to simultaneously communicate with their associated host computers connected to a network. Up to 4 terminals may be seated in the cradle. Additionally, up to 4 CRD1700-4000S serial cradles may be daisy-chained with this unit, providing a total of 20 slots available for host communications.

Theory of Operation Palm HotSync Manager software supports one HotSync at a time between a single terminal and a single PC. If the application requires multiple devices to communicate simultaneously with a single host, then synchronization server software such as Scout MTSTM or AVANTGOTM is required. This software may be purchased from Symbol. Contact your Symbol sales representative for information.

About This Guide This guide provides instruction on the setup and use of the CRD17004000E 4-slot Ethernet cradle. Additionally it describes steps to set up an SPT 1700 terminal for use with the CRD1700-4000E, and steps to setup the SPT 1700 Desktop Software to permit synchronization over an Ethernet network. Specifically, the following topics are discussed: • • • • • • •

Set Up on page 2 Unpacking the Cradle on page 2 Connecting Power on page 2 Setting Up for Network Communications on page 3 Inter-Connecting Cradles on page 9 Software Configuration on page 10 Performing HotSync on page 13.

1

Page 4

C R D 1 7 0 0 - 4 0 0 0 E E t h e r n e t C r a d l e

Set Up The set up of the cradle includes unpacking, placing the cradle on a table top and connecting the power and network communication cables. Before setting up the cradle, make sure that SPT 1500/1700 Desktop Software (p/n SW-35138-xx) is installed and running on the host computer, as well as properly configured Network HotSync software on the SPT 1700 terminal. See the SPT 1700 Product Reference Guide (p/ n 70-37544-xx) for instructions on the installation of this software. Specific software setup necessary to use the CRD1700-4000E is covered in this document.

Unpacking the Cradle The shipping box should include the following: • One 4-slot cradle (p/n CRD1700-4000E) • This Quick Reference Guide (p/n 72-39472-xx). No Ethernet cable is shipped with the cradle, but is required to connect the cradle to an Ethernet hub. You will also need: • 8Volt, 5Ampere power supply (p/n 50-14000-109). • AC line cord If any parts are missing or damaged, contact your authorized Customer Support Representative immediately at 1-800-659-2240 in the USA. See the back of this manual for contact information in other countries. Save the shipping box for storing or shipping.

Connecting Power To connect power to the cradle: 1. Connect the power supply cable plug to the Power Connector on the back of the cradle, as shown in the following illustration. 2. Connect one end of a standard 10 Base-T network cable to the connector labelled Host on the back of the CRD1700-4000E. Connect the other end of the cable to a hub which is connected to your subnet.

2

Page 5

Q u i c k

R e f e r e n c e

3. Connect the Power Supply AC plug to a standard electrical outlet, as shown in the following illustration.

Note:

International customers must use a separate AC line cord appropriate for their respective country. Power

Host

Expansion

HUB

4. The LED on each slot should blink red then green. The LEDs flash green while the cradle attempts to obtain its IP address from the DHCP server. If the cradle is successful in obtaining an address, the LEDs turn off. If the cradle is unsuccessful in its attempt to obtain its IP address from the DHCP server, the LEDs flash red, and the cradle retries in 10 minutes.

Setting Up for Network Communications The CRD1700-4000E cradle facilitates communication between SPT 1700 terminals and their associated host computers connected to an Ethernet network. As the CRD1700-4000E is an Ethernet device, it must be connected to an Ethernet network which is connected to the same network as the host computers, or an Ethernet network connected to the larger Internet via an Internet gateway. There are two methods by which this is accomplished: DHCP mode and Static mode.

DHCP Mode 1 DHCP Address Mode This is the factory default mode of the cradle. When using DHCP mode, the cradle acquires its IP address dynamically from the server. There must be a DHCP server or a DHCP relay agent on the same subnet as the CRD1700-4000E in order for the unit to be automatically

3

Page 6

C R D 1 7 0 0 - 4 0 0 0 E E t h e r n e t C r a d l e configured with an IP address, a gateway IP address, 2 DNS addresses, and a subnet mask. The single IP address is shared between all slots. To set up for network communications: 1. Ensure there is a DHCP server accessible to the CRD1700-4000E on the subnet. 2. Connect one end of a standard 10 Base-T network cable to the connector labelled Host on the back of the CRD1700-4000E. Connect the other end of the cable to a hub which is connected to your subnet. 3. Power-up the unit; the CRD1700-4000E performs its power-up sequence, then attempts to collect all its network parameters from the DHCP server. While collecting network parameters, all LEDs flash green. Once configuration completes, all LEDs shut off. If configuration of the unit from the DHCP server fails, all LED’s flash red. The unit retries the DHCP request every 10 minutes. Note:

Before communication between the SPT 1700 terminal and the host computer can take place, the SPT 1700 Desktop Software must be installed and running on the host computer.

6 DHCP Address Mode When using the 6 DHCP address mode, the cradle acquires 6 IP addresses dynamically from the DHCP server: one for the cradle, one for each of the 4 slots, and one for the expansion slot. This feature is not enabled when using NAT translation. To perform this configuration, run the flasher utility from the debug monitor. Follow steps 1 through 6 in Static Mode to access the Current Cradle Globals: menu. 1. Select option 1 for Static mode. Set both Static Mode and NAT Mode to 0 to acquire 6 IP addresses from the DHCP server. 2. Type F to write these values to Flash memory. 3. Type Q to quit the program and exit to E86mon. Cycle power to the cradle to effect the latest changes.

4

Page 7

Q u i c k

R e f e r e n c e

In this mode, each slot has its own IP address and may be directly accessed by the network. On power-up, the 6 IP addresses are acquired. Periodically, the lease times are checked and renewed as required. If the renewal request is NAKed by the server, the cradle enters Panic mode and re-boots. If the cradle receives no response from the server and is unable to re-bind, it also Panics and re-boots.

Static Mode If there is no DHCP server on your network, the cradle must be manually configured with IP addresses and other network-related information. This configuration is performed from the debug monitor (i.e., E86MON) by running the flasher utility. To enter the debug monitor: 1. Connect a null modem to a CRD1700-4000S host connector cable (p/n 70245-001). The null modem end should be connected to a COM port on the PC, and should be set to run at 115200 bps, 8N1, with XON/XOFF flow control and ASCII file transfer protocol, using a terminal emulator software, such as ProComm or Hyperterminal. 2. Connect the modular end to the expansion port of the CRD17004000E.

3. Power up the CRD1700-4000E. Before the power up LED sequence begins, type ‘a’ from the terminal program to enter the E86Mon. The following screen displays: Welcome to EtherCradle Monitor version x.xx! (?<Enter> for help)

er86mon:

4. Next, load the flasher utility into the cradle’s RAM by typing l2. Press Enter. The following screen displays: er86mon:l2 er86mon:

5

Page 8

C R D 1 7 0 0 - 4 0 0 0 E E t h e r n e t C r a d l e 5. Type ‘g’ and press Enter to run the flasher utility. The following screen displays: er86mon:g Cradle Utilities Version x.xx I) Flash Info P) Program Cradle Globals Q) Quit

6. Select ‘P’ to program the cradle’s global variables. The following screen displays: Current Cradle Globals: 1) Static mode: 0 NAT Mode: 1 2) Cradle IP Address: 192.168.111.1 3) Router (Gateway) IP Address: 192.168.111.1 4) 1st DNS IP Address: 0.0.0.0 5) 2nd DNS IP Address: 0.0.0.0 6) Subnet mask: 255.255.255.0 7) Diagnostic mode:0 Enter Field to Edit or: Q) quit without saving F) update globals and quit

Note:

Network parameters are used in Static mode only.

7. Select option 1, and update the Static mode setting to 1. Flasher asks you to specify the NAT mode. Enter 0 for no-NAT; enter 1 for NAT. Flasher asks for the Cradle IP Address. If your network uses a DHCP server, this IP address must be reserved for this CRD1700-4000E. See your network administrator for assistance. If you are not using NAT, you are asked to input the Static addresses for the 4 slots and the expansion slot. Note: To configure the cradle for DHCP use, the static mode setting must be ‘0’. 8. Select option 2, and update the cradle IP address. If your network uses a DHCP server, this IP address must be reserved for this CRD1700-4000E. Your network administrator should be able to assist you. 9. Select option 3, and update the Router IP address. This address should be set to the IP address of your internet gateway.

6

Page 9

Q u i c k

R e f e r e n c e

10. Select option 4 and 5, and set the DNS IP addresses for DNS1 and DNS 2. 11. Select option 6, and enter the correct subnet mask for your subnet. Note: When diagnostic mode is enabled (i.e., set to ‘1’), the CRD1700-4000E’s expansion serial port does not communicate with a CRD1700-4000S serial cradle. Instead, the CRD1700-4000E transmits diagnostic information at 115,200 bps, 8N1, using the expansion port. 12. Once all values are set correctly, type ‘F’ to write these values into flash memory. The terminal displays the following screen: Erasing flash sector at E0000... Cradle Utilities Version x.xx I) Flash Info P) Program Cradle Globals Q) Quit

13. Type ‘Q’ to quit the program and exit back to E86mon. The following screen displays. Program terminated with result code ‘00’ er86mon

14. Cycle power to the CRD1700-4000E so that the latest changes take affect.

Network Address Translation (NAT) In both DHCP and static mode, the cradle assigns private IP addresses to each terminal and performs Network Address Translation (NAT) on all TCP/IP and UDP/IP packets as they traverse through the cradle between the outside network and the cradle’s private network. The terminals are assigned private addresses according to the following table: Terminal Slot

IP Address

1

192.168.1.1

2

192.168.1.2

7

Page 10

C R D 1 7 0 0 - 4 0 0 0 E E t h e r n e t C r a d l e Terminal Slot

IP Address

3

192.168.1.3

4

192.168.1.4

Expansion

192.168.1.5

Note:

Do not use these IP Addresses on the terminal’s host TCP/ IP services.

The cradle also uses IP address 192.168.1.6, so this address, along with those listed in the above table must not be used by the outside network. The cradle modifies one IP address and port number pair inside a TCP/ IP and UDP/IP packet header. Those packets going to the outside network have their source address translated to the IP address of the cradle and their source port changed to unique port number that is associated with the cradle slot it came from. Conversely, packets designated to the cradle’s private network have their destination IP address and port number mapped to the equivalent private network IP address and port number. The differences in the port numbers distinguish between packets for different slots in the cradle. The benefit of both IP address and port translation is that multiple slots can simultaneously share the one network IP address of the cradle. Accessing the outside network with the CRD 1700-4000E is not equivalent to a direct connection to the outside network. The side effect of NAT is a collection of network services that do not function at all (e.g. FTP). Since NAT modifies addresses in TCP/IP and UDP/IP headers, it is insufficient for network services that embed IP addresses inside packet data (e.g.FTP client). Also, the CRD 1700-4000E assumes that a palm client sending data with one TCP or UDP source port expects to receive replies on the same port number. Unfortunately, this is not true for some network services that may reply with data over a range of ports. These network services are unusable with the CRD 1700-4000E. Another difficulty arises with services that listen to incoming requests from the network. Since port numbers are usually fixed for a given service, no palm terminals can be set up as listeners.

8