Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 1 of 2

CRD1500-4000E Ethernet Cradle Quick Reference, pages 1 to 10

Pages 1 to 10 of 20

The original document is the PDF (316 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Symbol CRD1500-4000

Page 1 read from a scan by OCR; it may hold reading errors

C R D 1 5 0 0 - 4 0 0 0 €E Et h eronet CGeraodteoe wy sane

Page 2

C R D

1 5 0 0 - 4 0 0 0 E

1999-2001 SYMBOL TECHNOLOGIES, INC. All rights reserved. Symbol reserves the right to make changes to any product to improve reliability, function, or design. Symbol does not assume any product liability arising out of, or in connection with, the application or use of any product, circuit, or application described herein. No license is granted, either expressly or by implication, estoppel, or otherwise under any patent right or patent, covering or relating to any combination, system, apparatus, machine, material, method, or process in which Symbol products might be used. An implied license exists only for equipment, circuits, and subsystems contained in Symbol products. Symbol and the Symbol logo are registered trademarks of Symbol Technologies, Inc. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. Symbol Technologies, Inc. One Symbol Plaza Holtsville, N.Y. 11742-1300 http://www.symbol.com

Patents This product is covered by one or more of the following U.S. and foreign Patents: U.S. Patent No. 4,593,186; 4,603,262; 4,607,156; 4,652,750; 4,673,805; 4,736,095; 4,758,717; 4,760,248; 4,806,742; 4,816,660; 4,845,350; 4,896,026; 4,897,532; 4,923,281; 4,933,538; 4,992,717; 5,015,833; 5,017,765; 5,021,641; 5,029,183; 5,047,617; 5,103,461; 5,113,445; 5,130,520; 5,140,144; 5,142,550; 5,149,950; 5,157,687; 5,168,148; 5,168,149; 5,180,904; 5,216,232; 5,229,591; 5,230,088; 5,235,167; 5,243,655; 5,247,162; 5,250,791; 5,250,792; 5,260,553; 5,262,627; 5,262,628; 5,266,787; 5,278,398; 5,280,162; 5,280,163; 5,280,164; 5,280,498; 5,304,786; 5,304,788; 5,306,900; 5,324,924; 5,337,361; 5,367,151; 5,373,148; 5,378,882; 5,396,053; 5,396,055; 5,399,846; 5,408,081; 5,410,139; 5,410,140; 5,412,198; 5,418,812; 5,420,411; 5,436,440; 5,444,231; 5,449,891; 5,449,893; 5,468,949; 5,471,042; 5,478,998; 5,479,000; 5,479,002; 5,479,441; 5,504,322; 5,519,577; 5,528,621; 5,532,469; 5,543,610; 5,545,889; 5,552,592; 5,557,093; 5,578,810; 5,581,070; 5,589,679; 5,589,680; 5,608,202; 5,612,531; 5,619,028; 5,627,359; 5,637,852; 5,664,229; 5,668,803; 5,675,139; 5,693,929; 5,698,835; 5,705,800; 5,714,746; 5,723,851; 5,734,152; 5,734,153; 5,742,043; 5,745,794; 5,754,587; 5,762,516; 5,763,863; 5,767,500; 5,789,728; 5,789,731; 5,808,287; 5,811,785; 5,811,787; 5,815,811; 5,821,519; 5,821,520; 5,823,812; 5,828,050; 5,848,064; 5,850,078; 5,861,615; 5,874,720; 5,875,415; 5,900,617; 5,902,989; 5,907,146; 5,912,450; 5,914,478; 5,917,173; 5,920,059; 5,923,025; 5,929,420; 5,945,658; 5,945,659; 5,946,194; 5,959,285; 6,002,918; 6,021,947; 6,029,894; 6,031,830; 6,036,098; 6,047,892; 6,050,491; 6,053,413; 6,056,200; 6,065,678; 6,067,297; 6,082,621; 6,084,528; 6,088,482; 6,092,725; 6,101,483; 6,102,293; 6,104,620; 6,114,712; 6,115,678; 6,119,944; 6,123,265; 6,131,814; 6,138,180; 6,142,379; 6,172,478; 6,176,428; 6,178,426; 6,186,400; 6,188,681; 6,209,788; 6,209,789; 6,216,951; 6,220,514; 6,243,447; 6,244,513; 6,247,647; 6,308,061; 6,250,551; 6,295,031; 6,308,061; 6,308,892; 6,321,990; 6,328,213; 6,330,244; 6,336,587; 6,340,114; 6,340,115; 6,340,119; 6,348,773; 6,380,949; 6,394,355; D305,885; D341,584; D344,501; D359,483; D362,453; D363,700; D363,918; D370,478; D383,124; D391,250; D405,077; D406,581; D414,171; D414,172; D418,500; D419,548; D423,468; D424,035; D430,158; D430,159; D431,562; D436,104. Invention No. 55,358; 62,539; 69,060; 69,187, NI-068564 (Taiwan); No. 1,601,796; 1,907,875; 1,955,269 (Japan); European Patent 367,299; 414,281; 367,300; 367,298; UK 2,072,832; France 81/03938; Italy 1,138,713 rev. 06/02

Page 3

Q u i c k

R e f e r e n c e

Introduction The CRD1500-4000E 4-slot Ethernet cradle enables up to 4 SPT 1500 terminals to simultaneously communicate with their associated host computers connected to a local area network. Up to 4 terminals may be seated in the cradle. Additionally, up to 7 CRD1500-4000S serial cradles may be daisy-chained with this unit, providing a total of 32 slots available for host communications.

Theory of Operation Palm HotSync Manager software supports one HotSync at a time between a single terminal and a single PC. If the application requires multiple devices to communicate simultaneously with a single host, then synchronization server software such as Scout MTSTM or AVANTGOTM is required. This software may be purchased from Symbol. Contact your Symbol sales representative for information.

About This Guide This guide provides instruction on the setup, use and maintenance of the CRD1500-4000E 4-slot cradle. Additionally it describes steps to set up an SPT 1500 terminal for use with the CRD15004000E, and steps to update the standard SPT 1500 Desktop Software to permit synchronization over an Ethernet network. Specifically, the following topics are discussed: • • • • • • •

Set Up on page 2 Software Configuration on page 8 The HotSync Process on page 12 Indicator Lights on page 14 Troubleshooting on page 15 Regulatory Information on page 16 Service Information on backcover.

1

Page 4

C R D

1 5 0 0 - 4 0 0 0 E

Set Up The set up of the cradle includes unpacking, mounting the cradle either on a wall or table top, and connecting the power and serial communication cables. Before setting up the cradle, make sure that SPT 1500 Desktop Software (p/n SW-35138-xx) is installed and running on the host computer, as well as properly configured Network HotSync software on the SPT 1500 terminal. See the SPT 1500 Product Reference Guide (p/n 70-33757-xx) for instructions on the installation of this software. Specific software setup necessary to use the CRD1500-4000E is covered in this document. Additionally, a DHCP server must be configured and operational on the subnet to which the cradle will be attached.

Unpacking the Cradle The shipping box should include the following: • One 4-slot cradle (p/n CRD1500-4000E) • A wall-cube power supply • This Quick Reference Guide (p/n 72-52665-xx). No Ethernet cable is shipped with the cradle, but is required to connect the cradle to an Ethernet hub. If any parts are missing or damaged, contact your authorized Customer Support Representative immediately at 1-800-6592240 in the USA. See the back of this manual for contact information in other countries. Save the shipping box for storing or shipping.

2

Page 5

Q u i c k

R e f e r e n c e

Connecting Power To connect power to the cradle: 1. Connect the power supply cable round plug to the Power Connector on the back of the cradle, as shown in the following illustration. Note:

Make sure the power supply is a 12V, 300ma power supply cable.

2. Connect the Power Supply AC plug to a standard electrical outlet, as shown in the following illustration. Note:

International customers must use a separate AC power cable appropriate for their respective country.

DC Power Connector

3. The cradle’s LEDs should blink, then remain off until a terminal is inserted into one or more of the slots.

3

Page 6

C R D

1 5 0 0 - 4 0 0 0 E

Setting Up for Network Communications The CRD1500-4000E cradle facilitates communication between SPT 1500 terminals and their associated host computers connected to any Ethernet network. As the CRD1500-4000E is an Ethernet device, it must be connected to an Ethernet network which is connected to the same network as the host computers, or an Ethernet network connected to the larger Internet via an Internet gateway. There must be a DHCP server on the same subnet as the CRD1500-4000E in order for the unit to be automatically configured with an IP address, a gateway IP address, and a subnet mask. The single IP address is shared between all slots. To set up for network communications: 1. Ensure there is a DHCP server accessible to the CRD15004000E on the subnet to which it will be attached. 2. Connect one end of a standard 10 Base-T network cable to the middle connector on the back of the CRD1500-4000E. Connect the other end of the cable to a hub which is connected to your subnet. 3. Power-up the unit; the CRD1500-4000E performs its powerup sequence, then attempts to collect all network parameters from the local DHCP server. While collecting network parameters, all LEDs flash green. Once configuration completes, all LEDs shut off.

4

Page 7

Q u i c k

R e f e r e n c e

If configuration of the unit from the local DHCP server fails, all LED’s flash red. The unit becomes unresponsive until the power is removed, the unit is connected to a network with a DHCP server, and power is restored. Note:

Before communication between the SPT 1500 terminal and the host computer can take place, the SPT 1500 Desktop Software must be installed and running on the host computer.

Inter-Connecting Cradles Up to seven 4-slot CRD1500-4000S serial cradles may be interconnected (daisy-chained) with the CRD1500-4000E using an RJ45/10 to RJ-45/10 inter-cradle cable (p/n 70246-001). This cable is required for each cradle to be connected.

WARNING Each cradle must have its own power supply. Any other method of power hookup is unsafe. To inter-connect cradles: 1. Connect the power supply to the second 4-slot cradle as described in the Connecting Power section. Note: You must use a 9V 300ma power supply on the serial cradle being connected to the ethernet cradle. 2. Plug one end of the inter-cradle cable into the modular jack labeled EXP on the back of the first cradle. The Expansion Connector is the modular jack located furthest from the Power Connector, as shown in the following illustration. 3. Plug the other end of the inter-cradle cable into the modular jack labeled Host on the back of the second cradle. The Host Connector is located between the Power Connector and the Expansion Connector, as shown in the following illustration.

5

Page 8

C R D

1 5 0 0 - 4 0 0 0 E

4. Repeat the previous steps for any additional 4-slot cradles you want to connect. Ethernet Cradle

Expansion Port

Serial Cradle

DC Power Port (use 12V, 3000ma Power Supply)

DC Power Port (use 9V, 3000ma Power Supply)

Ethernet Connection Port

Stacking Cradles Optionally, you can stack up to 4 cradles on top of each other seated on a table top. To stack the cradles, you’ll need the 4-slot cradle Stacking Kit, (p/n CRD1500-4000KT). Instructions for stacking the cradles are provided with the kit.

6

Page 9

Q u i c k

R e f e r e n c e

Wall-Mounting the Cradle The CRD1500-4000E 4-slot cradle can either be seated on a table top or mounted on a wall. Make all cable connections before wallmounting the cradle. To wall-mount the cradle: 1. Insert two screws appropriate for the mounting surface into the wall, 14 inches apart. These screws must be able to support a weight of at least 2.2 lbs. 2. Place the back of the cradle over the screws, aligning the wall-mount holes over the two screws, and pull down on the cradle to fasten onto the screws, as shown:

7

Page 10

C R D

1 5 0 0 - 4 0 0 0 E

Software Configuration The CRD1500-4000E appears to SPT 1500 terminals inserted into the cradle as a dial-up PPP service. Therefore, just as you would set up a Palm III terminal to connect to an Internet Service Provider (ISP) like Compuserve or Earthlink, the SPT 1500 terminals must be configured for use with the cradle. This section describes the steps necessary to configure both the SPT 1500 terminal and the CRD1500-4000E.

Installing NetSync An SPT 1500 terminal must have NetSync installed and configured for it to communicate with the CRD1500-4000E. Additionally, NetSync extensions to the HotSync Manager must be installed on the host system which the SPT 1500 terminal is to synchronize with. The Network HotSync software is a free add-on for the SPT 1500 and Palm Computing Platform series organizers and is available from the PalmComputing website at http:// www.palm.com/custsupp/downloads/netsync.html. Please note, in some later versions, such as Palm V, Network Hotsync is included as part of the desktop software. Follow the instructions to install the network HotSync software on your host PC, then perform a HotSync to install the program on your SPT 1500 terminal.

Configuring NetSync Options Once NetSync is installed on your SPT 1500 terminal, it must be configured for use with the CRD1500-4000E. From the HotSync panel on your SPT 1500, select each of the option panels available from the “Options” menu (accessed by tapping the Menu icon) and configure them as follows: 1. To configure the Modem Sync Preferences: a. Select the HotSync application from the main application screen. b. Select the menu icon to display the options menu. 8