The text of a manual · part 4 of 4

CRD 1500 Modem/Charging Cradle Quick Reference: Troubleshooting

Pages 12 to 20 of 20, from CRD 1500 Modem/Charging Cradle Quick Reference

The original document is the PDF (226 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol CRD1500-1000

Page 12

C R D 1 5 0 0 C h a r g i n g

M o d e m / C r a d l e

Troubleshooting If you’re having trouble with your modem cradle, check the following: • • • •

Ensure the connection to the telephone network and power supply is correct. Ensure the host application is running correctly on the terminal. Try another terminal if available. When using a PBX, ensure any requirements such as dialing 9 and ignoring dial tone are considered. In the unlikely event that your modem has locked up, remove power for a few seconds and re-apply. The operating system's manager (e.g., serial port, modem, internet) usually resets the modem processor when opening communications. If there are problems, the application automatically closes the manager and resets.

User and Service Access No part of the cradle, other than the line connection plug, is accessible to users.

Specifications The cradle contains a 14.400kbps (V32bis) modem with additional Data Compression to allow faster throughput, taking advantage of the higher serial port speeds of 57,600bps available to the terminal. Error Correction (MNP4, V42) is also included.

10

Page 13

Q u i c k

R e f e r e n c e

Regulatory Information Radio Frequency Interference Requirements USA (Home or office use) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. There is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on while observing for interference, the user is encouraged to correct the interference by employing one or more of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and the receiver. · Connect the equipment into an outlet that is on a circuit different from the receiver. · Consult the dealer or an experienced radio/TV technician for help. This device complies with FCC Part 15. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. CANADA This Class B digital apparatus complies with Industry Canada Standard ICES-003. Cet appareil numérique de la classe B est conform à la norme NMB-003 d’Industrie Canada.

Telecom Approval Warnings and Notices Connecting to the telephone network A compliant telephone lead is required with RJ11 plug (line is on middle pair) connection to modem, terminated with an appropriate and correctly wired local telecom connector compatible with the telephone network. Such a cable may be obtained from your local electronics supplier. Alternatively, compliant RJ11-plug-toRJ11-plug cables may be used with a range of adapters for places such as Europe. Caution: To reduce risk of fire, use only No. 26 AWG or larger telecommunications line cord. When installing, always connect the telecom cable first to the modem and then to the telecom network. Reverse the procedure on disconnection by first removing from the telephone network socket.

11

Page 14

C R D 1 5 0 0 C h a r g i n g

M o d e m / C r a d l e

USA This equipment complies with Part 68 of the FCC rules. A label is located externally on the equipment that contains, among other information, the FCC certification number and Ringer Equivalence Number (REN) for this equipment. If requested, this information must be provided to the telephone company. The REN is used to determine the quantity of devices that may be connected to the telephone line. Excessive devices on the telephone line may result in the devices not ringing in response to an incoming call. In most, but not all areas, the sum of REN’s should not exceed five (5.0). To be certain of the number of devices that may be connected to a line, as determined by the total REN's, contact the local telephone company. This equipment is designed to be connected to the telephone network or premises wiring using a compatible modular jack (RJ11C) that is FCC Part 68 compliant. An FCC compliant telephone cord and modular plug must be used. Should you experience trouble with this telephone equipment, please first contact your facility's Technical or Systems Support, who will contact your nearest Symbol Customer Service Center. If necessary, the Symbol Support Center may be contacted at the following: 1-800-653-5350 Symbol Support Center One Symbol Plaza Holtsville, NY 11742-1300 support@symbol.com If the equipment is causing harm to the telephone network, the telephone company may request that you disconnect the equipment until the problem is resolved. This equipment cannot be used on public coin phone service provided by the telephone company. Connection to party line service is subject to state tariffs. (Contact the state public utility commission, public service commission or corporation commission for information.) Your telephone company may discontinue your service if your equipment causes harm to the telephone network. They will notify you as soon as possible and, if practical, in advance of disconnection. During notification, you will be informed of your right to file a complaint to the FCC if you believe it is necessary. Occasionally, your telephone company may make changes to it's facilities, equipment, operations, or procedures that could affect the operation of your equipment. If so, you will be given advance notice of the change to give you an opportunity to maintain uninterrupted service. Statement of Fax Branding

12

Page 15

Q u i c k

R e f e r e n c e

The Telephone Consumer Protection Act of 1991 makes it unlawful for any person to use a computer or other electronic device to send any message via a telephone fax machine unless such message clearly contains in a margin at the top or bottom of each page or on the first page of the transmission, the date and time it is sent and an identification of the business or other entity, or other individual sending the message, and the telephone number of the sending machine, or such business, other entity, or individual. The telephone number provided may not be a 900 number or any other number for which charges exceed local or long-distance transmission charges. In order to program this information into your fax/modem consult your fax software user's manual for set-up instructions. CANADA The Industry Canada label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational, and safety requirements. The Department does not guarantee the equipment will operate to the user's satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions might not prevent degradation of service in some situations. Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines, and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. CAUTION: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate. NOTICE: The Ringer Equivalence Number (REN) assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices, subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed 5.0. AUSTRALIA The Australian Ringer Equivalence Number (REN) of this device is 0.1. The REN value is a guide to the maximum number of telecommunications devices that can be connected together, in parallel, to one telephone line. The maximum permitted REN value is 3.0 and hence the sum REN value of all connected devices must not exceed 3.0.

13

Page 16

C R D 1 5 0 0 C h a r g i n g

M o d e m / C r a d l e

EUROPE The equipment meets European Directive requirements for pan-European single terminal connection to the Public Switched Telephone Network (PSTN) using DTMF signalling (tone dial). However, due to differences between the individual PSTN's provided in different countries, this does not, of itself, give an unconditional assurance of successful operation on every PSTN network termination point. Note for Switzerland - Problems may be encountered due to Advice of Charge (AoC) tone bursts used for metering/ billing purposes. To avoid difficulties a cable or adapter containing an AoC 12kHz filter is necessary. In case of difficulty, please contact your equipment supplier for advice. In the event of any problems, you should contact your equipment supplier in the first instance. Parallel Equipment loading in Europe The Loading Factor (LF) is 22 Loading Units (LU) and should allow for the operation of several parallel connected equipment on the telephone line, should the application permit. The total loading of an installation can be obtained by adding the LU values of connected equipment. This can then be compared with the LF value that the telephone network can support as given by the operator of the telephone network. The total equipment LF should be less than the network LF to avoid risking a degradation in the equipment performance. (e.g. 4 items similar to this modem specification of 22 LU will operate on a network terminating point that can support 88 LU.)

14

Page 17

Q u i c k

R e f e r e n c e

DECLARATION OF CONFORMITY We,

Symbol Technologies, Inc.

of

One Symbol Plaza, Holtsville, NY 11742-1300, USA declare under our sole responsibility that this product: 1. Meets the essential requirements of Directive 1999/5/EC (R&TTE) and conforms to the standards listed below. The procedures detailed in Annex II of the directive have been followed. 2. Is designed to interwork with the following Public Switched Telephone Networks: Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Liechtenstein, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland, United Kingdom.

to which this declaration relates, is in conformity with the following standards and/or other normative documents. ETS TBR21: 1998 EN 60950: 1992 + A1-A4, A11 EN 55022: 1998 (Class B) EN 55024: 1998

Dornu Narnor (name) Senior Director, Regulatory (title)

September 2000 (signature of authorised person)

(date)

15

Page 18 read from a scan by OCR; it may hold reading errors

Modem /

15 0 0

D Cha e ad

C g r

16

Page 19

Q u i c k

R e f e r e n c e

Warranty Symbol Technologies, Inc. (“Symbol”) manufactures its hardware products in accordance with industry-standard practices. Symbol warrants that for a period of three (3) months from date of shipment, products will be free from defects in materials and workmanship. This warranty is provided to the original owner only and is not transferable to any third party. It shall not apply to any product (i) which has been repaired or altered unless done or approved by Symbol, (ii) which has not been maintained in accordance with any operating or handling instructions supplied by Symbol, (iii) which has been subjected to unusual physical or electrical stress, misuse, abuse, power shortage, negligence or accident or (iv) which has been used other than in accordance with the product operating and handling instructions. Preventive maintenance is the responsibility of customer and is not covered under this warranty. Wear items and accessories having a Symbol serial number, will carry a 90-day limited warranty. Non-serialized items will carry a 30-day limited warranty.

Warranty Coverage and Procedure During the warranty period, Symbol will repair or replace defective products returned to Symbol’s manufacturing plant in the US. For warranty service in North America, call the Symbol Support Center at 1-800-653-5350. International customers should contact the local Symbol office or support center. If warranty service is required, Symbol will issue a Return Material Authorization Number. Products must be shipped in the original or comparable packaging, shipping and insurance charges prepaid. Symbol will ship the repaired or replacement product freight and insurance prepaid in North America. Shipments from the US or other locations will be made F.O.B. Symbol’s manufacturing plant. Symbol will use new or refurbished parts at its discretion and will own all parts removed from repaired products. Customer will pay for the replacement product in case it does not return the replaced product to Symbol within 3 days of receipt of the replacement product. The process for return and customer’s charges will be in accordance with Symbol’s Exchange Policy in effect at the time of the exchange. Customer accepts full responsibility for its software and data including the appropriate backup thereof. Repair or replacement of a product during warranty will not extend the original warranty term. Symbol’s Customer Service organization offers an array of service plans, such as on-site, depot, or phone support, that can be implemented to meet customer’s special operational requirements and are available at a substantial discount during warranty period.

General Except for the warranties stated above, Symbol disclaims all warranties, express or implied, on products furnished hereunder, including without limitation implied warranties of merchantability and fitness for a particular purpose. The stated express warranties are in lieu of all obligations or liabilities on part of Symbol for damages, including without limitation, special, indirect, or consequential damages arising out of or in connection with the use or performance of the product. Seller’s liability for damages to buyer or others resulting from the use of any product, shall in no way exceed the purchase price of said product, except in instances of injury to persons or property. Some states (or jurisdictions) do not allow the exclusion or limitation of incidental or consequential damages, so the proceeding exclusion or limitation may not apply to you.

Page 20

Service Information Before you use the unit, it must be configured to operate in your facility’s network and run your applications. If you have a problem running your unit or using your equipment, contact your facility’s Technical or Systems Support. If there is a problem with the equipment, they will contact the Symbol Support Center: United States

1-800-653-5350

Canada

905-629-7226

United Kingdom

0800 328 2424

Asia/Pacific

337-6588

Australia

1-800-672-906

Austria

1-505-5794

Denmark

7020-1718

Finland

9 5407 580

France

01-40-96-52-21

Germany

6074-49020

Italy

2-484441

Mexico

5-520-1835

Netherlands

315-271700

Norway

66810600

South Africa

11-4405668

Spain

9-1-320-39-09

Sweden

84452900

Latin America Sales Support

1-800-347-0178 Inside US +1-561-483-1275 Outside US

Europe/Mid-East Distributor Operations

Contact local distributor or call +44 208 945 7360

72-52018-01 Revision A, May 2001 Symbol Technologies, Inc. One Symbol Plaza Holtsville, NY 11742-1300