The text of a manual · part 8 of 8
Spectrum24 CB2000 Client Bridge Product Reference Guide, pages 51 to 56
Pages 51 to 56 of 56: Chapter 5 Troubleshooting; Appendix A Specifications; Appendix B Customer Support
The original document is the PDF (631 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol CB-2000
Page 51
Chapter 5
5.1
Troubleshooting
Diagnosing Problems If the Spectrum24 CB2000 is experiencing difficulties, try the following: Symptom
Solutions
After changing the IP address, restoring a backup configuration, or resetting the bridge to factory defaults, the Configuration Management System stops responding, keeping the user from making additional configuration changes.
Once the IP address is changed and a user clicks Apply All Changes, the CB2000 loses the network connection with the workstation, which is now on a different IP address. To keep this from happening, click Enter to continue configuring the device after changing the IP address. Similarly, restoring a backup configuration or resetting the bridge to factory defaults can change the IP address setting. To recover from this situation and continue configuring the bridge: 1. Close the browser. 2. Return to the Spectrum24 CB2000 Device Manager and click Refresh. 3. Select the device and click Configure to start a new configuration session.
The bridge cannot associate with an access point.
•
Adjust the position of the bridge to improve reception.
•
Launch the bridge configuration and verify the security settings, advanced performance settings, and access point privacy mode settings on the bridge match those on the access point.
Spectrum24 CB2000 Client Bridge Product Reference Guide
45
Page 52
Troubleshooting
46
Two workgroup bridges cannot communicate in Ad Hoc (Peer-to-Peer) mode.
•
Adjust the positions of the bridges to improve reception.
•
To ensure correct operation in ad hoc mode, the settings on the two bridges must match exactly. Launch the bridge configuration management system and verify the Wireless LAN Service Area, channel selections, Data Preamble setting, and security setting are the same on both bridges.
The wireless network tree does not appear in the Spectrum24 CB2000 Device Manager window.
Verify the correct network adapter is chosen and operating properly. In the device manager window, click Choose NIC. Select the network adapter and click OK.
After upgrading the system, custom configuration settings are lost.
Under some circumstances, upgrading the firmware and the configuration management system forces a return to configuration defaults. In this case, launch the bridge configuration and reconfigure the settings.
Spectrum24 CB2000 Client Bridge Product Reference Guide
Page 53
Appendix A
Specifications
A.1 Physical Characteristics Height: 109 mm (4.29 in) Width: 82 mm (3.24 in) Depth: 39 mm (1.52 in)
A.2 Environmental Operating Ranges Temperature: 0 to 40°C (32 to 104°F) Humidity: 10 to 95% non-condensing
A.3 Network Characteristics Driver Support: NDIS v4.0 and v5.0 Ethernet Frame: DIX, Ethernet_II and IEEE 802.3 Filtering Packet Rate: 14,400 frames per second filtering and forwarding Ethernet Connection: 10/100Base-T (AP-4131 model access point only) SNMP s24dsap.mib, MIB-II and 802.1x.mib
A.3.1 Features •
Embedded HTTP Web management server in each access point works with any Web browser that supports HTML and Javascript
•
Remote configuration capable.
A.3.2 Protocol Support •
TCP/IP
•
IPX
•
NetBEUI
•
DHCP.
Spectrum24 CB2000 Client Bridge Product Reference Guide
A-1
Page 54
A.3.3 Security •
40-bit WEP and 128-bit (shared and session key) encryption
•
Kerberos
A.3.4 Standards Conformance
A-2
•
IEEE 802.11b High Rate
•
IEEE 802.11
•
IEEE 802.3
•
IEEE 802.1d
•
HTTP
Spectrum24 CB2000 Client Bridge Product Reference Guide
Page 55
Appendix B
Customer Support Symbol Technologies provides its customers with prompt and accurate customer support. Use the Symbol Support Center as the primary contact for any technical problem, question or support issue involving Symbol products. If the Symbol Customer Support specialists cannot solve a problem, access to all technical disciplines within Symbol becomes available for further assistance and support. Symbol Customer Support responds to calls by email, telephone or fax within the time limits set forth in individual contractual agreements. When contacting Symbol Customer Support, please provide the following information: • serial number of unit
• model number or product name
• software type and version number.
B.1 North American Contacts Inside North America, contact Symbol by: •
Symbol Technologies, Inc. One Symbol Plaza Holtsville, New York 11742-1300 Telephone: 1-631-738-2400/1-800-SCAN 234 Fax: 1-631-738-5990
•
Symbol Support Center (for warranty and service information): – telephone: 1-800-653-5350
– fax: (631) 563-5410
–
Email: support@symbol.com
Spectrum24 CB2000 Client Bridge Product Reference Guide
B-1
Page 56
B.2 International Contacts Outside North America, contact Symbol by: •
Symbol Technologies Symbol Place Winnersh Triangle, Berkshire, RG41 5TP United Kingdom 0800-328-2424 (Inside UK) +44 118 945 7529 (Outside UK)
B.3 Web Support Sites MySymbolCare http://www.symbol.com/services/msc Symbol Services Homepage http://symbol.com/services Symbol Software Updates http://symbol.com/service/downloads Symbol Developer Program http://software.symbol.com/devzone Symbol Knowledge Base http://kb.symbol.com
B.4 Additional Information Obtain additional information by contacting Symbol at:
B-2
•
1-800-722-6234, inside North America
•
+1-631-738-5200, in/outside North America
• http://www.symbol.com/
Spectrum24 CB2000 Client Bridge Product Reference Guide