The text of a manual · part 7 of 8
Spectrum24 CB2000 Client Bridge Product Reference Guide: Chapter 4 CB2000 Device Manager
Pages 47 to 50 of 56, from Spectrum24 CB2000 Client Bridge Product Reference Guide
The original document is the PDF (631 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol CB-2000
Page 47
Chapter 4
4.1
CB2000 Device Manager
Installing the Device Manager Follow these steps to install the Device Manager on a workstation: 1. Insert the Software and Documentation CDROM in the CD-ROM drive. The setup menu appears. If it does not appear, start the setup menu from the Windows Start menu. For example: Start, Run, D:setup.exe. 2. In the menu, click Install the Tools and Documentation. 3. Follow the displayed instructions to complete the installation. If prompted, reboot the computer.
4.2
Device Manager Interface The Spectrum24 CB2000 Device Manager provides a useful interface for accessing Spectrum24 wireless devices and launching their configurations in a standard Web browser. Use the management tool to: •
View Spectrum24 CB2000 devices
•
Change CB2000 IP and subnet mask settings
•
Launch the Configuration Management System for a selected device.
The interface buttons perform the following functions: Properties. Displays the following properties of the selected device: Device Name, Device Type, Wireless LAN Service Area (ESSID), IP Address, Subnet Mask, and MAC Address. Configure. Launches the Configuration Management System for the selected device. If the selected device is on a different subnet, the Pre-IP Configuration Wizard prompts the user to assign an address on the same subnet as the workstation. Refresh. Scans the network and displays the connected Spectrum24 CB2000 devices.
Spectrum24 CB2000 Client Bridge Product Reference Guide
41
Page 48
CB2000 Device Manager
Choose NIC. If the workstation has more than one network interface card installed, select this button to choose which card to use. Close. Closes the device manager window and ends the session. Help. Launches the device manager help page in a browser.
4.3
Pre-IP Configuration Wizard The Pre-IP Configuration Wizard allows a user to enter a preferred IP and subnet setting or accept a suggested setting for the CB2000. Use this wizard to temporarily access a CB2000 to view or change configuration parameters. A user can only configure devices on the same subnet as their workstation. To configure a device on a different subnet, a user must first assign it an IP address on the same subnet as their workstation. When a user selects Configure from the Device Manager and the IP address and subnet settings of their workstation and CB2000 are different, the Pre-IP Configuration Tool launches automatically to facilitate setting new IP and subnet values for the workstation to communicate with the CB2000. Perform the following to use the wizard: 1. In the Wireless Infrastructure Device Pre-IP Configuration window, accept the suggested settings or change them as required. – You can assign a static IP address or specify that the device obtain its IP address from a DHCP server. 2. The next window prompts for an administrative password to allow the new IP address to be set. When the units are shipped from the factory, there is no administration password. Leave the password field blank. If an administration password has been set for the device, enter the password and click Next. The Configuration Management System main page appears in the Web browser. 3. Make changes to the configuration settings as usual.
42
Spectrum24 CB2000 Client Bridge Product Reference Guide
Page 49
CB2000 Device Manager
4. After completing all other changes, do the following: –
If configuring a new CB2000 for use on a network, click Apply All Changes.
–
If changing or viewing parameters from a workstation and the Pre-IP Configuration Wizard changed the IP and subnet settings for the sole porpose of communicating with the device, click IP Network. In the IP Network page, restore the IP address to its original setting and click Apply All Changes.
5. Close the browser window. After changing the IP address, the configuration session is disrupted. To continue configuring, follow these steps after closing the browser: 1. Return to the Device Manager window. 2. Click Refresh. 3. Select the device and click Configure. 4. Repeat the procedure for using the Pre-IP configuration wizard.
Spectrum24 CB2000 Client Bridge Product Reference Guide
43
Page 50
CB2000 Device Manager
44
Spectrum24 CB2000 Client Bridge Product Reference Guide