The text of a manual · part 2 of 3
High Rate CB 2000 Client Bridge, pages 11 to 20
Pages 11 to 20 of 28
The original document is the PDF (905 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol CB-2000
Page 11
Default Setting
IP Network Setting
Default IP address = 10.1.1.3
IP Address
Obtained automatically
Subnet Mask
Obtained automatically
Gateway IP Address
Obtained automatically
Channel Selection
Automatically select the best channel; uses access point setting.
Channel
Uses access point channel.
Wireless LAN Service Area
Attach to any WLAN Service Area automatically
Network Mode
Access Point (infrastructure)
Access Point Privacy Mode
Off
Antenna Selection
Diversity
Network Traffic Accelerator
Off (802.11b)
Data Preamble
N/A (Not applicable)
Security Setting
No Security (Open System)
Administration Password
None
TFTP Server IP Address
None (Uses TFTP port 69.)
9
Installing the CB2000
Property
Page 12
• Closed network with security requirements Use the administration tool to locate and configure the CB2000 and organize devices to manage the wireless LAN and keep it secure.
Step 4 - Verify Operation Perform visual verification that operating LEDs are working properly and the device is communicating with the network. 10
Connect the CB2000 The CB2000 is designed to be connected to an Ethernet client device such as a hub, telephone, computer, or printer. Do not connect a CB2000 set in Access Point (Infrastructure) mode directly to the LAN (for example, through a wall port). Such a connection could cause a transmission loop between the CB2000 and an access point, which could disrupt network operation.
Page 13
Computer Connection The CB2000 can be connected directly to a computer. The CB2000 can convert a desktop computer to a wireless computer. Use this type of connection to configure the CB2000 before connecting it to another device or location on the wireless LAN.
Installing the CB2000
11
Page 14
Hub Connection Supply network connections for up to four devices, such as computers and network printers, by connecting the CB2000 to an Ethernet hub. Use a hub connection to configure the CB2000 in the location it will reside.
12
Make sure that the CB2000 Ethernet cable is plugged into the hub uplink (MDIX) port. If the hub does not have an uplink port, use an Ethernet crossover cable (not provided), which can be connected in any port.
Page 15
Install the CB2000 Device Manager To install the Spectrum24 CB2000 Device Manager on the computer: 1. After verifying the computer is operational, insert the Software and Documentation CDROM in the CD-ROM drive. The setup menu appears. If it does not appear, start the setup menu from the Windows Start menu. For example: Start/Run/D:setup.exe.
3. Follow the instructions on the screens to complete the installation. If prompted, reboot the computer.
13
Installing the CB2000
2. In the menu, click Install the Tools and Documentation.
Page 16
Configure the CB2000 If installing the CB2000 on an open network with DHCP, skip this section and go to Verify Operation to ensure the device is operating correctly. Launch the Device Manager tool to record IP and subnet settings for the newly installed CB2000. These settings are needed for relocating the device on the network.
14
To configure the CB2000 for a closed network or a network with any type of security, change the default configuration settings with the Spectrum24 CB2000 Device Manager. When initially configuring the CB2000, it is recommended to use the supplied standard Category 5 UTP Ethernet cable to connect it directly to the computer where the device manager is installed. Once the CB2000 is configured to associate with the wireless network, remove the supplied Ethernet cable and change its configuration at any time from any location on the network. To launch the Device Manager and configure the CB2000: 1. Select Start/Programs/Symbol Wireless/CB2000 Device Manager. If more than one network adapter is installed on the computer, the user could be prompted to choose a network adapter. Choose the appropriate adapter and click OK. The Wireless Network Tree appears in the Spectrum24 CB2000 Device Manager window. The tree lists all WLAN service areas on the network and expands to show the Spectrum24 LAN devices associated with each service area. Devices in a different subnet are identified with exclamation points (!). To refresh this display, click Refresh. Refresh the display, for example, after changing a device IP address.
Page 17
2. In the Wireless Network Tree, select the device to configure. If more than one wireless LAN device appear in the tree, determine the right one by clicking Properties and checking the MAC address (serial number, located on the bottom of the device) to verify it is correct. 3. Click Configure.
5. If the selected device is on a different subnet, the Pre-IP Configuration Wizard is activated automatically. Use this wizard to configure the IP settings for the selected CB2000. It proposes IP address and subnet mask settings derived from the computer's settings, so the selected device resides on the same subnet as the computer. Accept the suggested settings or change them as required. For more information, see Using the Pre-IP Configuration Wizard in the Spectrum24 CB2000 Client Bridge Reference Guide. 6. The next window prompts for an administrative password to allow the new IP address to be set. When the units are shipped from the factory, there is no administration password. Set an administration password and click Next. The Configuration Management System main page appears in the Web browser. 7. Enter configuration parameters necessary for communicating with the network. See online help and the Spectrum24 CB2000 Client Bridge User Guide for additional information on setting and changing configuration settings.
15
Installing the CB2000
4. If the selected device is on the same subnet as the computer, the Configuration Management System main page appears in the Web browser. (If a password is set on the device, enter it when prompted.)
Page 18
8. After saving the configuration, disconnect the bridge from the computer and connect it in its permanent place in the network. The default installation is complete. For advanced configuration alternatives, refer to the user guide.
16
Page 19
Verify Operation When the bridge is connected to power, verify operation through two LEDs. Location
Description
Wireless Association
On the top of the bridge
On -- Unit is receiving power. Off -- Unit is not receiving power. Blinking -- The unit is transmitting or receiving.
Ethernet Connection
At the RJ45 Ethernet Connector
On -- Unit has an Ethernet connection. Off -- Unit does not have an Ethernet connection. Blinking -- Wired LAN traffic is detected. Faster blinking indicates heavier traffic.
In addition to LED operation, verify proper operation by accessing a network resource using a computer connected to the CB2000. If the LEDs do not function and network resources cannot be accessed, verify the following: • All physical connections, including power. • Configuration settings. • Verify there is a working 802.11b access point within 100 meters. If the CB2000 is not operating, consult the Troubleshooting section of the Spectrum24 CB2000 Client Bridge User Guide for additional information.
17
Installing the CB2000
LED Indicator
Page 20
Customer Support Symbol Technologies provides its customers with prompt and accurate customer support. Use the Symbol Support Center as the primary contact for any technical problem, question or support issue involving Symbol products.
18
If the Symbol Customer Support specialists cannot solve a problem, access to all technical disciplines within Symbol becomes available for further assistance and support. Symbol Customer Support responds to calls by email, telephone or fax within the time limits set forth in individual contractual agreements. When contacting Symbol Customer Support, please provide the following information: • Device serial number • product name and/or model number • software type and version number.
North American Contacts Inside North America, contact Symbol at: Symbol Technologies, Inc. One Symbol Plaza Holtsville, New York 11742-1300 Telephone: 1-631-738-2400/1-800-SCAN 234 Fax: 1-631-738-5990 Symbol Support Center (for warranty and service information) telephone: 1-800-653-5350 fax: (631) 563-5410 Email: support@symbol.com