Page 1
High Rate
CB 2000 Client Bridge
Page 2
Page 3
To the User Document Conventions ........................................................................................2 Warnings ............................................................................................................3
Installing the CB2000
Contact Information Customer Support...............................................................................................18
Legal Information Regulatory Information ......................................................................................20 Applying the Regulatory Country Stamp ................................................................20 Statement of Compliance for Integrated Radio Device ............................................22 Copyright and Patent Information ........................................................................23
1
Table of Contents
Introduction........................................................................................................4 Preparation ........................................................................................................5 Obtaining Product Updates and Tools......................................................................6 Installation Steps ................................................................................................7 Connect the CB2000 ..........................................................................................10 Install the CB2000 Device Manager ......................................................................13 Configure the CB2000 ........................................................................................14 Verify Operation ................................................................................................17
Page 4
To the User This Quick Setup Guide contains: • Basic installation and configuration procedures • Product information for the Symbol Technology Spectrum24 CB2000 Client Bridge. Refer to this guide and the documentation on the CDROM for information on installing, configuring, and using the client bridge. 2
Document Conventions Before operating the CB2000, review this document for any hazards associated with installation and use of the device. Also, review standard practices for preventing accidents.
Indicates tips, hints and special requirements. Care is required. Disregarding cautions can cause data loss or equipment damage. Indicates a potentially dangerous condition or procedure that only Symbol-trained personnel should attempt to correct or perform.
Page 5
Warnings • Read all installation instructions and site survey reports, and verify correct equipment installation before connecting the system to its power source. • Verify any device connected to this unit is properly wired and grounded. • Attach only approved cables to this device.
• Verify uninterruptible power sources, if equipment is carrying emergency traffic.
3
To the User
• Verify adequate ventilation around the device, and ambient temperatures meet equipment operation specifications.
Page 6
Introduction The Spectrum24® High Rate CB2000 Client Bridge from Symbol Technologies is a wireless network bridge allowing up to four devices to connect to a Wi-Fi IEEE 802.11b wireless local area network (LAN), or communicate directly with other mobile devices enabled for wireless LAN connectivity. Features include: 4
• Compatible with NBX® communication systems to deploy fully managed voice and data networks • Hub connections for up to four users per bridge provide affordable wireless connections • Client tools for open networks with DHCP • Remote manageability using a standard web browser or SNMP management tool • Auto Network Connect keeps roaming users connected with a choice of ad hoc or infrastructure networks • Support for 40-bit and 128-bit wired equivalent privacy (WEP) and Kerberos encryption.
Page 7
Preparation Before beginning the installation, verify the hardware package contains: • A Spectrum24 CB2000 Client Bridge • A power adapter and power cord. • A standard Category 5 unshielded twisted pair (UTP) Ethernet cable. • A Spectrum24 CB2000 Client Bridge Software and Documentation CDROM. The following items (which are not included) are also required: • A computer with network access to a Wi-Fi compliant wireless LAN access point. The computer requires one of the following operating systems and one of the following browsers to use the CB2000 Device Manager. Use the administration tool to select Spectrum24 CB2000 devices and launch their configuration management systems. • Operating Systems
Windows XP, Windows 2000, Windows NT 4.0, Windows Me, Windows 98
• Browsers
Netscape 4.7 or later, Internet Explorer 5.0 or later
Windows 95 is not supported. If configuring the CB2000 using a non-Windows computer, see the readme file on the install CD. • An Ethernet crossover cable to connect the CB2000 to a hub that does not have an uplink (MDIX) port.
Installing the CB2000
5
Page 8
Obtaining Product Updates and Tools Symbol periodically updates firmware and user documentation. Symbol also provides downloadable tools to assist with installing and configuring the CB2000. Go to the Symbol Technology Web site at http://www.symbol.com/services/downloads/dwnload_spec24_select.html to download firmware updates, drivers, tools and documentation. 6
Page 9
Installation Steps The following steps outline installation and configuration for the CB2000.
Step 1 - Connect the CB2000
The CB2000 supports up to four specific Ethernet client devices. It uses a client list of MAC addresses to keep track of specific devices connected to the device. Each time a new device is connected to the bridge, either directly or through a hub, that device's MAC address is added to the client list. After connecting four different devices, the client list is full. To connect another new device, clear the device to be replaced from the client list before the next new device can associate with the network through CB2000. To clear the device from the list, access the bridge's configuration management system. See the CB2000 User Guide for details.
7
Installing the CB2000
The CB2000 is designed to be connected to an Ethernet client device such as a hub, telephone, computer or printer. Before connecting the bridge, decide where to place it and whether or not the default configuration is to be accepted. Place the bridge in a dry, clean location near the hub, telephone, computer or printer connected to the bridge. The location must have a power source and be within 300 feet (100 meters) of a Wi-Fi compliant wireless LAN access point. The location should be away from transformers, heavy-duty motors, fluorescent lights, microwave ovens, refrigerators or other equipment that could cause radio signal interference.
Page 10
Step 2 - Install the Device Manager The Spectrum24 CB2000 Device Manager is an administration tool to select Spectrum24 CB2000 devices and launch their configurations in the Web browser. To configure a CB2000, the device manager is required to be installed on a computer that has an Ethernet adapter and is running one of the Windows operating systems and Web browsers listed in Preparation section. 8
If the IP address of the unit is known, the user can browse to it from another computer on the same subnet without the use of the Device Manager. The Device Manager can display multiple CB2000s on a subnet, as well as the properties of each one. Click the Configure button to open a Web browser used for device configuration.
Step 3 - Configure the CB2000 The type of network and level of security used with the CB2000 dictates the steps necessary to configure the device. • Open system, DHCP server, no special security requirements Use the CB2000 as it ships from the factory. After connecting the device and verifying network access, use the administration tool to obtain specific information, such as ip and MAC addresses, which are necessary for relocating the device in a network. The following table shows the CB2000 factory default configuration.