The text of a manual · part 16 of 18
Spectrum24 CB 1000 User Guide: Appendix A Troubleshooting
Pages 115 to 120 of 134, from Spectrum24 CB 1000 User Guide
The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol CB-1000
Page 115
Troubleshooting
Appendix A
Troubleshooting
A.1 Problems Encountered during setup Most installation problems can be solved by carefully progressing through these steps: •
Ensure power is applied and light is illuminated
•
Insert one end of the paper clip in the hole labeled Config the serial LED momentarily illuminates
•
When using the Ethernet port ensure the Ethernet LED is illuminated green. If not illuminated green the wrong cable is in use or the client has not enabled the Ethernet NIC
•
The RF association LED is illuminated green. If not illuminated: –
Ensure that the Reset To Default procedure has been performed after installing the radio
–
The ESSID matches the AP
–
Antennas are installed on the AP and the client is within range.
Spectrum24 CB 1000 User Guide
107
Page 116
Troubleshooting
A.2 Hardware Error Diagnosis Indication
Problem
Power LED is off or The CB 1000 is not the power LED is receiving power blinking. properly.
Verify all physical connections are secure. Contact Technical Support if the problem persists.
Power LED is steady and the error LED is illuminated.
Check the System Event Log to determine the error, and refer to the following Event Log Error.CB 1000
Configuration or software error
CB 1000 is Invalid connection to connected to an Ethernet Ethernet cable, but the Ethernet Link LED is not lit.
108
Corrective Action
Verify both ends of the cable are plugged in securely. If the CB 1000 is attached to a hub, use a crossover Ethernet cable. If the CB 1000 is attached directly to an Ethernet device (a PC or Ethernet printer), use a straight-through cable. If the correct cable is being used, verify connection is to a 10BaseT Ethernet device. The CB 1000 does not support 100BaseT.
Spectrum24 CB 1000 User Guide
Page 117
Troubleshooting
Indication
Problem
Corrective Action
Radio Association The radio is not linking LED is not to the access point. illuminated LED and the Status LED is off.
Verify the radio is a Symbol Technologies CB 1000 supported radio. Verify the ESSID matches the access point. Perform the Reset To Default procedure ( see 5.2.5 Resetting to factory defaults on page 32) any time a radio card is installed.
FLASH failure. Unable to read or write configuration.
FLASH could be damaged. Configuration cannot be accessed or saved.
Contact Symbol Technologies Technical Support.
Initialization of interface lan0 failed.
Radio could not be initialized.
Follow these steps. Continue to the next step until the problem is resolved. 1. Reset the CB 1000. 2. Unplug the power. Wait approximately 30 seconds and apply power. 3. Reset the CB 1000 to the factory default configuration and reset the CB 1000. 4. Contact Symbol Technologies Technical Support if the problem persists.
Spectrum24 CB 1000 User Guide
109
Page 118
Troubleshooting
Indication
Problem
Corrective Action xxxx: file does not exist.
Configuration file could not be found.
Reset the configuration to Factory Default, and reset the CB 1000. If the problem persists, contact Symbol Technologies Technical Support.
A.3 Event Log Error Table All entries in the event log are preceded by a number. This number is a timestamp used by Technical Support, but is not relevant to looking up items in this table.
110
Configuration Error Code
Error Code Explanation
Corrective Action xxxx: [yyyy]: section does not exist
Section named [yyyy]: in configuration file named xxxx: is missing.
Save the current configuration (if applicable). Reset the CB 1000 configuration to Factory Default. Reset the CB 1000. Restore configuration (if applicable).
xxxx: [yyyy]: "zzzz": entry refers to nonexistent section
Entry zzzz refers to a section that is not located in file xxxx.
Save current configuration (if applicable). Reset the CB 1000 unit configuration to Factory Default. Reset the CB 1000. Restore configuration (if applicable).
Spectrum24 CB 1000 User Guide
Page 119
Configuration Error Code
Error Code Explanation xxxx: [yyyy]: "zzzz": entry does not exist
Entry zzzz in section yyyy of file xxxx was missing.
Save current configuration (if applicable). Reset the CB 1000 unit configuration to Factory Default. Reset the CB 1000. Restore configuration (if applicable).
xxxx: [yyyy]: "zzzz": entry is invalid
Entry zzzz in section yyyy of file xxxx contains an invalid value.
Check the entry in the configuration for zzzz. If it cannot be found in the Configuration Manager program, use the serial port or telnet configuration menus.
Unable to bring up interface "lanX".
Configuration values for the radio could be incorrect.
Check the configuration for the PCMCIA radio Ethernet card used.
Xxxx: <[yyyy]zzzz>: Unable to add route.
Route values are out of range compared to the interface values.
Set the route value to automatic. If automatic does not work, check the route values. Ensure the values correspond to the other IP parameters.
UART Error - No Rx Buffer Available
Data is being sent to the UART at a rate faster than it can clear its receive buffers, and data is being lost.
Enable flow control for the serial application. If using the the serial port menu system for configuration, flow control is not enabled in the CB 1000. Enter data slower to avoid getting this error while in the serial port configuration system.
Spectrum24 CB 1000 User Guide
Corrective Action
111
Page 120
Troubleshooting
Configuration Error Code Any other errors
112
Error Code Explanation
Corrective Action Contact Technical Support, before continuing.