Page 107

Main Menu Configuration Screens

[tcpbind2] protocol = tcp type = listen local tcp port = 4000 reopen after shutdown = on #socket connect data = "Please login: " #serial connect data = "Received listener connection." 0xd 0xa #serial disconnect data = "Disconnected from listener." 0xd 0xa #serial fail data = "Accept failed." 0xd 0xa

[tcpbind3] protocol = tcp type = connect ip address = 10.10.10.129 remote tcp port = 4000 reopen after shutdown = on #socket connect data = "Hello!" 0xd 0xa #serial connect data = "Connected to socket." 0xd 0xa #serial disconnect data = "Disconnected from socket." 0xd 0xa #serial fail data = "Connection failed." 0xd 0xa

• protocol –

• local tcp port –

•

TCPBIND1a, TCPBIND1b, TCPBIND2, and TCPBIND3, use the TCP protocol, so the value of this entry is tcp. This port defines the TCP port number the CB 1000 uses for connections from other networked devices. Type is set to listen (tcpbind2) for this port to be used.

reopen after shutdown –

If the type is listen (tcpbind2), this value ( default is on) determines whether a second connection is accepted after the first connection terminates. If the type is connect (tcpbind3), this value determines whether another connection attempt is made if the first connection is closed by the remote computer.

Spectrum24 CB 1000 User Guide

99

Page 108

Main Menu Configuration Screens

• socket connect data –

• serial connect data –

•

The values in this entry can be either listen or connect. This specifies whether the CB 1000 waits for a connection from another computer or attempt to initiate the connection itself.

ip address –

100

When the socket connection fails, the data is written to the UART. This happens in the case of a connect type where the remote machine was unavailable or refused the connection. This value can be used to catch listen to problems. The format is the same as in socket connect data.

type –

•

Serial disconnect data is written to the UART when the network connection is closed. The data is appended to any data already in progress. The closing of the socket does not cancel UART transmission of data received over the socket. The format of this data is the same as in socket connect data.

serial fail data –

•

The serial connect data format is the same as the socket connect data. Data is written to the UART upon a successful connection.

serial disconnect data –

•

Socket connect data is data written to the connection once the connection is made. The value can be specified as a combination of a string and ASCII values. For example, the default value is "Hello!" 0xd 0xa. (The double-quote marks are a part of this value). This example would cause 8 bytes to be written to the socket; these are, in hexadecimal, 0x48 0x65 0x6c 0x6c 0x6f 0x21 0x0d 0x0a. The data could be specified on this line by using the eight hexadecimal values instead of a combination of string and hex.

The ip address is used in the TCP protocol to specify the address to connect. Connect must be selected for the IP address to be used.

Spectrum24 CB 1000 User Guide

Page 109

Main Menu Configuration Screens

• remote tcp port –

The remote tcp port specifies the TCP port address used for remote computer connection. Use connect for this port.

10BaseT Ethernet (lan0) [hardware] network id = 101 station name = CB 1000 mac address = detect 005004e8381c # station or microap radio mode = station dsmu = no transmit rate = 1 2 drop zero length packets = yes enable encryption = no

Settings for the actual CB 1000 hardware are determined under this category. The 10BaseT Ethernet category varies depending on the particular radio being used. • station name –

Assign a unique name to a CB 1000 device in this field. Any alphanumeric name can be used. The reserved name for accepting any ESSID is Any. The AP must be enabled to accept broadcast ESSID.

Spectrum24 CB 1000 User Guide

101

Page 110

Main Menu Configuration Screens

•

MAC address –

• radio mode –

•

DSMU mode is available only with the Spectrum24 2Mbps FH radio card. It bridges multiple Ethernet stations and performs like a wireless AP while retaining the roaming properties of an MU, but does not support associations with other MUs. An MU in DS MU mode functions as part of the distribution system, as defined by 802.11. Default value is set to no change this value to yes to enable DS MU mode.

transmit rate –

102

Sets the radio to station or microap. In station (default) mode the CB 1000 can be used in configurations within the Infrastructure or Peer-to-Peer network topologies. In the microap mode the CB 1000 acts as an AP. It establishes a single-cell wireless network coverage area for other CB 1000 devices in station mode. A unique ESSID is required for the CB 1000 in microap mode.

dsmu –

•

A MAC address is a 48-bit number written as six hexadecimal bytes separated by colons. Spectrum24 devices, like other Ethernet devices, have unique, hardware-encoded, alphanumeric, Media Access Control (MAC) or IEEE addresses that define each node on the network. Values for this setting are: detect (default setting) the CB 1000 assumes the MAC address of the device on the CB 1000's ethernet port; builtin The CB 1000's builtin MAC address is used or a specific MAC address can be used by entering a 12 character MAC address without the colons for the value. For example, to use MAC address 01:23:45:67:89:ab, enter 0123456789ab. Use the value detect save for wired to wireless ethernet bridging.

The data rate at which the radio transmits is set by this field. Valid values are radio dependent.

Spectrum24 CB 1000 User Guide

Page 111

Main Menu Configuration Screens

• enable encryption –

This value is used to indicate whether WEP encryption by the radio is enabled or not. If the radio in the CB 1000 does not support setting WEP, this option does not appear (all Symbol Technologies radios supported by the CB 1000 support WEP encryption). Set the various encryption options in the [encryption] section.

encryption Symbol uses the Wired Equivalent Privacy (WEP) algorithm, specified in IEEE 802.11 section 8, for encryption and decryption. WEP uses the same secret key for both encrypting and decrypting plain text. Typically, an external key management service distributes the secret key. Only the sender and receiver of the transmitted data know the secret key. Symbol recommends that users periodically change keys for added security. The CB 1000 and the AP are required to have matching keys. Modify both to maintain data transmissibility. • transmit key –

• encryption key 1 –

•

This value specifies the encyption key used to encrypt transmitted data. The CB 1000 and the AP are required to have matching keys. The default setting is 1. Use this value for encrypting and decrypting data on the radio. The key should be specified as either a 10 digit or a 26 digit hexadecimal number. The number should always have a 0x before the hexadecimal digits. Use 10 digits for a 64 bit key, and 26 digits for a 128 bit key. 128 bit key is only supported on High Data Rate (HR) Direct Sequencing (DS) Spectrum24 radios.

encryption key 2 –

Use this value for encrypting and decrypting data on the radio. The key should be specified as either a 10 digit or a 26 digit hexadecimal number. The number should always have a 0x before the hexadecimal digits. Use 10 digits for a 64 bit key, and 26 digits for a 128 bit key.

Spectrum24 CB 1000 User Guide

103

Page 112

Main Menu Configuration Screens

• encryption key 3 –

•

Use this value for encrypting and decrypting data on the radio. The key should be specified as either a 10 digit or a 26 digit hexadecimal number. The number should always have a 0x before the hexadecimal digits. Use 10 digits for a 64 bit key, and 26 digits for a 128 bit key.

encryption key 4 –

Use this value for encrypting and decrypting data on the radio. The key should be specified as either a 10 digit or a 26 digit hexadecimal number. The number should always have a 0x before the hexadecimal digits. Use 10 digits for a 64 bit key, and 26 digits for a 128 bit key.

ip Set the configuration of the IP protocol. • ip address –

• netmask –

•

When logically ANDed with the IP address, specifies the range of IP addresses within the local network.

broadcast –

104

Assign the IP address used by other computers to communicate with a particular CB 1000.

In the local network, this is the IP address used to refer to all computers simultaneously. The default automaticly works for almost all configurations. There should be no need to change this value.

Spectrum24 CB 1000 User Guide

Page 113

• route –

•

This value references section names that specify the routing options for the network interface card (radio card). The default of automatic works for most configurations.

gateway –

The value specifies the IP address of the Internet router or firewall. By default, the value is set to none. Change this value to the IP address of the gateway if an Internet router or firewall is be used.

Spectrum24 CB 1000 User Guide

105

Page 114

106