Page 19
To set Unicast Wireless RPL transmissions: 1. Sign on to the 4690 Master store controller. 2. At the main menu, select Installation and Update Aids. 3. Select Change Configuration. 4. Select Controller Configuration.
Note:
Perform the following on all Master and Alternate Master controllers with the wireless feature installed and selected.
5. Select User Defined Logical File names. 6.
Define logical file name ADXRPLWL. When asked if it is OK to define this name with an IBM reserved name, answer yes.
7. Define ADXRPLWL to 1. 8. Exit configuration. 9. Select Activate Configuration. 10. Select Controller Configuration. 11. After the configuration activation, re-IPL all store controllers. The RPL server within the store controller(s) now transmits the terminal operating system in unicast mode to the wireless terminals. Wired Ethernet terminal loading is not affected by the configuration change.
Spectrum24 CB1000 For IBM 4690 Terminals User Guide
16
Page 20
To set MultiCast Wireless RPL transmissions: 1. Sign on to the 4690 Master store controller. 2. At the main menu, select Installation and Update Aids. 3. Select Change Configuration. 4. Select Controller Configuration.
Note:
Perform the following on all Master and Alternate Master controllers with the wireless feature installed and selected.
5. Select User Defined Logical File names. 6. Erase logical file name ADXRPLWL. When asked if it is OK to erase this name with an IBM reserved name, answer yes. 7.
Exit the configuration
8.
Select Activate Configuration.
9.
Select Controller Configuration.
10. After the configuration activation, re-IPL all store controllers. The RPL server within the store controller(s) now transmits the terminal operating system in multicast mode to the wireless terminals. Wired Ethernet terminal loading is not affected by the configuration change.
ADXWLSPD - Speed-up wireless terminal loading Use the ADXWLSPD parameter with wireless networks faster than 1Mbps. The terminal load time can be reduced when a value for this parameter is set.
Spectrum24 CB1000 For IBM 4690 Terminals User Guide
17
Page 21
When loading a wireless terminal, the controller delays about 60ms between each RPL load block to avoid overrunning the bandwidth of the wireless network. ADXWLSPD controls the number of load blocks sent per delay. The default is one block per delay. The default delay was designed for a dual controller system with a 1Mbps network. Since the controller cannot detect the speed of the wireless terminals, the user can configure ADXWLSPD to speed up the load. Set ADXWLSPD based on the slowest wireless terminal in the network. Note that an 11Mbit radio can scale back to 5.5 or 2 or 1 Mbps based on the radio signal from the AP. The Symbol recommended setting is close to the speed of the slowest wireless terminal. This option only applies to RPL loaded terminals and doesn’t affect PXE loading. Speed of slowest wireless terminal
Recommended setting
1Mbit
ADXWLSPD = 1 (Default)
2Mbit
ADXWLSPD = 3
5Mbit
ADXWLSPD = 5
11Mbit
ADXWLSPD = 10
Note:
Setting the ADXWLSPD value too high causes the controller to send blocks faster than the wireless network can transmit them. This causes load blocks to be thrown away and the terminals take a long time to load.
If ADXWLSPD is not defined, the default value is 1. Base 4690 OS does not define this Logical Name.
Spectrum24 CB1000 For IBM 4690 Terminals User Guide
18
Page 22
To define the User Logical Name ADXWLSPD: 1. Sign on to the 4690 Master store controller. 2. At the main menu, select Installation and Update Aids 3. Select Change Configuration. 4. Select Controller Configuration.
Note:
Perform the following on all Master and Alternate Master controllers with the wireless feature installed and selected.
5. Select User Defined Logical File names. 6. Define User logical file name ADXWLSPD. When asked if it is OK to erase this name with an IBM reserved name, answer yes. 7. Define the logical name with a value between 1 and 15 8. Exit the configuration 9. Select Activate Configuration. 10. Select Controller Configuration. 11. After the configuration activation, re-IPL all store controllers.
Changing DLC Retry and Time-out Values Data between controllers and terminals can be lost depending on network traffic conditions. In instances of data loss, the driver retries transmission 4 times. Timers T1 and Ti define retry transmissions. If set high, the chance of a successful retry is high but it could take longer to complete a transmission. If set low, the transmission takes less time but the chance of successful transmission is low (In this case, the terminals could go off-line).
Spectrum24 CB1000 For IBM 4690 Terminals User Guide
19
Page 23
Manually set timers T1 and Ti in respect of network traffic conditions. These timers can be set with the logical name ADXWLNTO. The higher ADXWLNTO, the higher T1 and Ti. ADXWLNTO is defaulted to maximum delay.
Note:
To use the default setting, do not define the logical name ADXWLNTO.
To define the User Logical Name ADXWLNTO: 1. Sign on to the 4690 Master store controller. 2. At the main menu, select Installation and Update Aids 3. Select Change Configuration. 4. Select Controller Configuration.
Note:
Perform the following on all Master and Alternate Master controllers with the wireless feature installed and selected.
5. Select User Defined Logical File names. 6. Define User logical file name ADXWLNTO. When asked if it is OK to erase this name with an IBM reserved name, answer yes. 7. Exit the configuration 8. Perform Steps 1 – 7 for all the other controllers. 9. Select Activate Configuration. 10. Select Controller Configuration. 11. After the configuration activation, re-IPL all store controllers.
Spectrum24 CB1000 For IBM 4690 Terminals User Guide
20
Page 24
ADXSLLD4 - Controller Throttle for Terminal Loading 4690 OS does not use the ADXSLLD4 user logical name. ADXSLLD4 was replaced with ADXLDLY4.
ADXLDLY4 – Controller Throttle for Terminal Loading The ADXLDLY4 option is for pacing wired LAN terminal loads and should not be used to throttle wireless loads.
3.5
PXE Loading With the release of the 4690 OS V2R4, a function was added to support terminals using PXE to load the operating system. To take advantage of the new loading method, the Symbol Client Bridge and Access Point require configuration modifications.
Access Point Setup The Access Point Multicast Mask (V) is required to be "01005E2E", without quotes. The entry or Multicast Mask (D) is "03004000", without quotes. Locate the parameter on the "Set RF Configuration" screen for the Access Point.
Client Bridge Setup The CB1000 MAC ADDRESS is required to be "dynamic", without quotes. Locate the parameter on the "Bridged Ethernet" screen for the Client Bridge.
Spectrum24 CB1000 For IBM 4690 Terminals User Guide
21
Page 25
IBM Terminal Setup For 4694-2x7 and 4694-3x7 models: 1. From the Main Menu select "Boot Sequence" and set the following: •
"1st Boot Source" to "Drive A"
•
"2nd Boot Source" to "System board 10/100 Ethernet"
•
"RPL Boot Protocol" to "PXE"
2. From the Main Menu select "ASIC Setup" and set the following: •
"NVRAM start address" to "DD000"
•
"NVRAM 1st 4k" to "Enabled"
•
"NVRAM 2nd 4k" to "Page 1"
•
"SRAM Start Address" to "DC000"
•
"SIO Interrupt" to "IRQ7"
3. From the Main Menu select "Advanced System Setup". 4. Select "I/O Device Configuration". 5. Set Parallel Port to "Disabled". 6. Save the settings. 7. Exit System Setup and IPL the terminal. 8. The terminal reloads with the new parameters.
Spectrum24 CB1000 For IBM 4690 Terminals User Guide
22
Page 26
IBM 4690 Controller Setup The 4690 OS file ADXTRMDF.DAT is required to include the following entry: "BRDCST=1" Enter "BRDCST=1" without quotes. Run terminal load shrink by typing ADXRTCCL from OS command prompt and re-ipl the controllers. The remainder of the system configuration would be as you have already completed for your Ethernet attached PXE loaded terminals.
Converting a Wireless Terminal to a Wired Terminal To a configure a wireless terminal back to a wired terminal: Remove Ethernet cable from the CB and plug it into the IBM 4690 Controller’s Ethernet hub.