3 Configuration Converting an Ethernet based 4694 or SurePOS terminal to a wireless terminal requires: • configuring the Access Point
• configuring the Client Bridge
• configuring the terminal for wireless communications
• configuring logical names for application and performance.
3.1
Access Point Configuration The following fields require configuration prior to installation in the retail environment. • the Net_ID (ESS)
• the Multicast Mask is required to be 03000004.
•
Symbol recommends enabling WEP (encryption).
Configure the parameters through the Access Point User Interface (UI). The UI is a maintenance tool integrated into the Access Point. It provides statistical displays, AP configuration options and firmware upgrades. Access to the UI requires one of the following: •
TCP/IP Telnet Client
• direct serial connection
Spectrum24 CB1000 for IBM 4690 Terminals User Guide
7
Page 11
• dial up access
•
SNMP using a MIB browser
•
Web browser.
Refer to the Access Point Product Reference Guide (available from http://www.symbol.com/services/downloads for more details). To configure the Access Point using a Direct Serial Connection:
Note: The UI and serial port are enabled on the AP: 1. Attach a null modem serial cable from the AP to the terminal or PC serial port. 2. Start the communication program (such as HyperTerminal for Windows) from the terminal. 3. Select the COM port along with the following parameters. • emulation
ANSI
• baud rate
19200 bps
• data bits
8
• stop bits
1
• parity none
• flow control none
There is no password requirement to view the Main Menu or statistics. 4. Press ESC to refresh the display. The AP displays the Main Menu.
Spectrum24 CB1000 For IBM 4690 Terminals User Guide
8
Page 12
5. From the Main Menu, select Enter Admin Mode and enter the password. The default password is Symbol.
Note:
The password is case-specific.
6. Enter the Net_ID (ESS). Select AP Installation From the UI Main Menu. Tab to Net_ID (ESS). Enter a unique value (1-32 alphanumeric characters, case sensitive) and press Enter twice. 7. Enter the Multicast Mask. From the UI Main Menu, select "Set RF Configuration". Tab to Multicast Mask. Enter 03000004. Press Enter twice to enter the configuration value. 8. Save the configuration. From the UI Main Menu, select Special Functions. Tab to Save Configuration and press Enter. At the prompt “Are you sure? yes no”, press y to save. 9. Power the Access Point off and then on to reset. 10. Connect the Access Point to the IBM 4690 Controller Ethernet LAN.
Spectrum24 CB1000 For IBM 4690 Terminals User Guide
9
Page 13
3.2
Client Bridge Configuration Some Client Bridge setup is required prior to installation in the retail environment. • set the ESSID to the Net_ID (ESS) on the AP. ESSID is case sensitive
• check “IBM RPL Support” within the Client Bridge Network options.
Note:
CB1000 firmware version 2.27 or later is required. The CB1000 Configuration Utility Version 2.33 or later supports the “IBM RPL Support” option.
Note:
If using the Serial Port Protocol to configure the Client Bridge, add the line “pos support = yes” under the [bridge] keyword in the System Options. If Locally Administered Addresses (LAA) is configured for the terminals, set the CB1000 Radio Advanced Parameter "MAC Address" to dynamic.
Client Bridge parameters can be set with a Windows Configuration utility or through a terminal emulation (Hyperterm for Windows for example) and a RS-232 Serial Cable. For more configuration details or instructions on updating the CB firmware, refer to the Spectrum24 CB1000 User Guide available at http://www.symbol.com/services/downloads.
Spectrum24 CB1000 For IBM 4690 Terminals User Guide
10
Page 14
The CB1000 Configurator utility (provided with the CB1000) operates on a host PC or workstation running Windows 95/98 or 2000. Refer to the README.TXT file on the CD included with the CB1000 for installation instructions. The utility enables the user to graphically and remotely: • display the CB1000 units running on t he local network
• display and edit the current configuration of any CB1000
• save and load configurations to and from the local host
• update the CB1000 firmware.
To configure the CB1000 using the Windows Configuration utility: 1. Insert a Symbol Technologies supported radio in the CB1000 (CB). 2. Connect the CB directly to a Windows PC with an Ethernet Cable. 3. Power on the CB. 4. Start the CB1000 Configurator program on the Windows PC. 5. From the CB1000 Unit List, double-click on the target CB. Match the serial number of the CB displayed in the Unit List window with the serial number found on the bottom of the CB to identify the correct CB. 6. Verify the CB Firmware version is 2.27 or later. If the CB firmware is earlier than 2.27, obtain the latest firmware from Symbol (http://www.symbol.com/services/downloads). 7. Verify the CB1000 Configuration Utility is Version 2.33 or later. If the Configuration Utility is earlier than 2.33, obtain the latest version from Symbol (http://www.symbol.com/services/downloads). 8. Click on the Network tab.
Spectrum24 CB1000 For IBM 4690 Terminals User Guide
11
Page 15
Select the “IBM RPL Support” box. If “Enable Bootp” is an option, select “No”. 9. Click the Radio tab. Click the Basic tab. Enter the ESSID. This is a case sensitive alphanumeric field that should match the NET_ID (ESS) parameter on the AP. For a 2MB radio, set the Radio mode to Station. For an 11MB radio, set the Operating Mode to Infrastructure. 10. Click the Advanced tab. If Locally Administered Addresses (LAA) is configured for the terminals, set the "MAC Address" parameter to ”dynamic”. If LAA is not configured, click either “capture” or “dynamic”. Select Antenna Diversity. For a 2MB radio, Transmit rates 1 and 2 should display. For an 11MB radio, Transmit rates 1, 2, 5, and 11 should display. If the wrong rates are displayed for the inserted radio, use the “Reset to Default” option under File, remove power from the Client Bridge and return to Step 1. 11. Click “Update and Reset Unit”. A “Upload and reset successful” message displays. The CB is ready to connect to the 4694/SurePOS terminal.
Spectrum24 CB1000 For IBM 4690 Terminals User Guide
12
Page 16
3.3
IBM Terminal Setup To convert an Ethernet based 4694/SurePOS terminal from wired to wireless: 1. Plug the Ethernet cable from the terminal into the Client Bridge. 2. Reboot the Client Bridge. The terminal is ready for wireless operation.
3.4
IBM 4690 Controller Setup There are no required changes to the controller configuration, but several parameters are available to optimize the performance of wireless systems and reduce terminal load times. These parameters are changed using User Logical Names.
Note: Verify the 4690 OS level supports the CB1000. The User Logical Names are: •
ADXRPLWL - Selects Unicast vs. Multicast Remote Program Load
•
ADXWLSPD - Speed-up terminal load.
•
ADXSLLD4/ ADXLDLY4- Controller Throttle
•
ADXWLNTO - Change the number of DLC retries.
•
ADXRPLWL - Unicast vs. Multicast Remote Program Load.
Spectrum24 CB1000 For IBM 4690 Terminals User Guide
13
Page 17
ADXRPLWL – Unicast vs MultiCast Remote Program Load
In a 4690 OS environment, 4694 and SurePOS terminals load their terminal OS images from a store controller in a multi-stage process. First, the hardware adapter responsible for the network connection to the store controller sends a broadcast message in search of a store controller. For LAN based hardware adapters (for example, token-ring, Ethernet, and wireless) the store controller discovery is performed using Remote Program Load (RPL) protocol messages. When a store controller receives a load request from a hardware adapter, it first transmits a small piece of code (referred to as a bootstrap) to the terminal. Once the bootstrap is loaded and control is transferred to it, the bootstrap requests the load of the 4690 terminal OS image from the store controller. When the 4690 terminal OS image is loaded, the bootstrap passes control to it and terminal IPL begins. The 1st Stage (the bootstrap load) is transmitted to wireless terminals in unicast (or point-to-point) mode. In Stage 2 (the terminal Operating System load) the OS can be transmitted either in the unicast or multicast mode. The final stage (application load) is transmitted in unicast mode. In Unicast mode, the server transmits LAN data directly to the adapter issuing the request. In Multicast mode, the server transmits LAN data to a group of adapters, which are all able to receive data addressed to a designated destination. In Broadcast mode, the server transmits LAN data to all adapters. Multicast is differentiated from broadcast as multicast data is sent to a certain group of adapters on the LAN (for example, all wireless adapters, but not Ethernet adapters). On wireless LANs, unicast transmissions are acknowledged at various points and provide higher reliability compared with multicast transmissions, which have a higher rate of data loss. Symbol recommends using unicast communications for wireless LANs.
Spectrum24 CB1000 For IBM 4690 Terminals User Guide
14
Page 18
Although unicast transmissions are more reliable than multicast, the amount of data transmitted for a large number of terminals can be greater. In addition, unicast load time increases proportionally to the number of terminals being loaded. Conversely, in multicast mode, load time increases only slightly with an increasing number of terminals. There is more of a leveling effect of load time as the number of terminals is increased. The 4690 OS RPL server is designed to transmit either multicast or unicast loads to wireless POS terminals. By default, 4690 OS RPL servers transmit in multicast mode. To override the multicast default setting and set the store controller to unicast mode, a user logical file name is required to be defined on the store controller(s) enabled for the wireless LAN feature. This file (ADXRPLWL) defines whether the controller operates in a unicast or multicast mode for wireless terminals. Unicast is Symbol recommended setting. Unicast is more reliable and loads a single terminal faster than multicast. However, multicast can load a large number of wireless terminals (15+) faster, especially in slower wireless networks. As the speed of the wireless network increases, the advantage of multicast goes down. If a site has 1-15 terminals on a 2Mbit wireless network, define ADXRPLWL to enable unicast loading. With more than 15 wireless terminals, do not define ADXRPLWL, which enables multicast loading. If there are problems loading terminals, unicast is a more reliable load protocol. Experiment with both modes to determine which one provides the shortest most reliable terminal load time.
Note: Multicast is the default setting. A single terminal loads faster in unicast than multicast. On faster wireless networks, unicast can support a higher number of terminals. The value assigned to ADXRPLWL is meaningless. The existence of the logical name forces unicast loading.
Spectrum24 CB1000 For IBM 4690 Terminals User Guide
15