Motorola (Symbol) installation guide for the 1-Port Power-over-Ethernet Power Injector, part AP-PSBIAS-1P2-AFR, which sends power and Ethernet data to an access point over one cable. It names the AP100, AP200, AP300 and AP-5131 as the supported devices. The reader can check the specifications, cable the injector, read its LEDs and work through common problems.
- What it is
- Single-port 802.3af Power over Ethernet injector, part AP-PSBIAS-1P2-AFR p. 1
- Supported devices
- AP100, AP200, AP300 and AP-5131; one device per injector p. 1
- Output power
- 15.4W at 48V minimum continuous per port (minimum 12.95W at the PDTE) p. 1
- Network
- 10/100BaseT Ethernet over TIA/EIA-568 Category 5 (or higher) cabling p. 1
- Connectors
- Shielded RJ-45 Data In and Data & Power Out sockets; AC power input on the back p. 1
- Maximum cable length
- 100 meters (333 ft) from the Ethernet source through the injector to the AP p. 1, 2
- Power cord
- Not supplied; three-conductor with IEC 60320 coupler, rated 250VAC RMS and 5A minimum (or 18AWG) p. 1
- Operating temperature
- 0°C to 40°C (32°F to 104°F) p. 1
- Operating humidity
- 10% to 93% non-condensing p. 1
- Protection
- Underload, overload, short-circuit and under/over voltage port protection p. 1
- Mounting
- Free standing on a level surface or wall mounted with key holes; units join with a coupling rail p. 1, 2
- Power switch
- None; ready as soon as AC power is applied p. 2
- LEDs
- Steady green: AC power received, device connected; blinking green: output voltage out of range, or overload or short circuit p. 2
- Document
- 72-99410-01 Revision A, May 2007 p. 1
What this manual walks you through
- Preparing the site for the Power Injector p. 1
- Cabling the Power Injector between the network and the access point p. 1
- Joining several Power Injectors with the coupling rail p. 2
- Reading the Power Injector LEDs p. 2
- Fixing a Power Injector that does not power up p. 2
- Fixing an AP that gets no power or no Ethernet p. 2
Good to know
- The injector does not repeat or amplify the Ethernet signal; place it as close as possible to the network data port. p. 1
- Using the injector with an unsupported Motorola device could make that device inoperable. p. 1
- The building must supply short-circuit protection: a fuse or breaker no larger than 120 VAC, 3A (U.S.) or 240VAC, 1.5A (international). p. 1
- Do not connect the injector to an outlet whose voltage differs from the label. p. 1
- Category 5 foiled twisted-pair cables are needed to meet Class B emission limits. p. 2
Questions this manual answers
What PoE injector works with the Symbol AP-5131?
The Motorola 1-Port Power Injector, part AP-PSBIAS-1P2-AFR, which also supports the AP100, AP200 and AP300. p. 1
How much power does the AP-PSBIAS-1P2-AFR deliver?
A minimum continuous output of 15.4W at 48V per port, and it meets IEEE 802.3af. p. 1
How long can the cable be with the Power Injector?
No more than 100 meters (333 ft) from the Ethernet source to the injector and the AP. p. 2
Does the Power Injector come with a power cord?
No. It needs a certified three-conductor cord with an IEC 60320 coupler and a grounded plug. p. 1
Power Injector port light is off and the AP does not work
The injector did not detect the AP. Check for a straight-wired four-pair 5/5e/6 cable, the Data In and Data & Power connections, and shorts, or try another injector. p. 2
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
(2)
(1)
72-99410-01 Revision A May 2007
- Read the installation instructions before connecting the Power Injector to a power source.
- Follow basic electricity safety measures whenever connecting the Power Injector to its power source.
- This product relies on on the building installation for short-circuit (over current) protection. Ensure a fuse or circuit breaker no larger than 120 VAC, 3A U.S. (240VAC, 1.5A international) is used on the phase conductor.
- A volatge mismatch can cause equipment damage and could pose a fire hazard. If the voltage indicated on the label is different from the power outlet voltage, do not connect the Power Injector to that particular outlet.
- The Power Injector Data In and Data & Power Out ports are shielded RJ-45 sockets. Only RJ-45 data connectors should be connected to these sockets.
http://www.motorola.com MOTOROLA INC. 1303 E. ALGONQUIN ROAD SCHAUMBURG, IL 60196 11-8095311 315-271700 01-40-96-52-21
France7020-1718Denmark/Danmark1-800-672-906Australia0800 328 2424United Kingdom
1-800-653-5350 1-631-738-2400
United States+47 2232 4375Norway/Norge5-520-1835Mexico/México6074-49020Germany/Deutschland9 5407 580Finland/Suomi1-505-5794-0Austria/Österreich+65-6796-9600Asia/Pacific905-629-7226Canada
- Power Injector (pt # AP-PSBIAS-1P2-AFR) Inspect the package contents and report any missing or damaged items to your sales representative. The packages should contain the following:
Verifying Package Contents
Installation Guide
Before using the unit, it must be configured to operate in the facility’s network and run your applications. If you have a problem running your unit or using your equipment, contact your facility’s Technical or Systems Support. If there is a problem with the equipment, they will contact Motrola.
1-Port Power-over-Ethernet
Power Injector
This guide is intended for the technician responsible for installing the Power Injector. It assumes the technician is familiar with basic Ethernet LAN-based networking and device installation concepts. This guide provides specifications, procedures and guidelines to use during the installation process. This guide does not provide site-specific installation procedures. For detailed site-specific installation procedures, refer to the site-specific documentation derived from site survey and site network analysis.
To the Installer
Service Information
- Only trained and qualified personnel should install and remove the Power Injector.
- A power cord is not supplied with the device. Use only a correctly rated power cord that’s certified, as appropriate, for the country of operation.
- The power cord must be a three-conductor type (two current carrying conductors and one ground conductor) terminated on one end by an IEC 60320 appliance coupler (for Power Injector connection) and on the other end by a plug containing a ground (earth) contact.
- The power cord must be rated for a minimum of 250VAC RMS operation, with a minimum rated current capcity of 5A [or a minimum wire gauge of 18AWG (0.75mm²)].
- The AC wall-socket outlet must be near the Power Injector and easily accessible.
- The Power Injector Data and Data & Power interfaces are qualified as SELV (Safety Extra-Low Voltage) circuits according to to IEC 60950. These interfaces can only be connected to SELV interfaces on other equipment. Before operating any equipment, review this document for any hazards associated with installation and use of the device. Also, review standard practices for preventing accidents.
Safety Information
- Underload, overload, short-circuit & under/over voltage port protection.
2-484441
- Universal AC Input: 110/220 V, 60/50 Hz.
Netherlands/Nederland
- Supports standard 10/100BaseT Ethernet networks over a standard TIA/EIA-568 Category 5 (or higher) cabling
Italy/Italia
- This Power Injector Installation Guide (72-99410-01)
- Independent power controller (SPEAR™), CPU controller and input (Data) and output (Data + Power) shielded RJ-45 connectors
Spain/España
The Power Injector has the following features:
- Minimum port output continuous allowable power of 15.4W at 48V (minimum 12.95W at the PDTE) AP-5131
91 324 40 00 Inside Spain
to AP-5131 LAN PortSouth AfricaWarnings
+34 91 324 40 00 Outside Spain
A separate Power Injector is required for each device comprising the network. The Power Injector supports the following devices; AP100, AP200, AP300 and AP-5131.
- Meets the IEEE 802.3af standard
Power Injector84452900PowerSweden/SverigeData
1-800-347-0178 Inside US +1-954-255-2610 Outside US
The Motorola Power Injector (pt # AP-PSBIAS-1P2-AFR) is a single-port, 802.3af compliant Power over Ethernet hub combining low-voltage DC with Ethernet data in a single cable connecting to an AP. The Power Injector’s single DC and Ethernet data cable creates a modified Ethernet cabling environment eliminating the need for separate Ethernet and power cables.
Latin America Sales Support
The Power Injector is a small lightweight unit with a RJ-45 Ethernet cord input connector from the hub on the front right-hand side of the unit and a RJ-45 data and power output connector to the AP on the front left-hand side of the unit. On the back of the unit is a 110-220 VAC power input.
Caution - Using the Power Injector with an unsupported Motorola device could render the device inoperable and void your warranty.
Product Description
Contact local distributor or call +44 118 945 7360
When users purchase a WLAN solution, they often need to place access points in obscure locations. In the past, a dedicated 24-hour, 90-264 VAC power source was required for each access point in addition to the Ethernet infrastructure. This often required an electrical contractor to install power drops at each access point location. With the Motorola Power Injector solution (pt # AP-PSBIAS-1P2-AFR), centralized power can be provided for devices without a local power supply for each.
Europe/Mid-East Distributor Operations
Introduction
Technical Specifications
Installation Preparing for Site Installation
Physical Specifications Width Height Depth Weight
58.5mm 31mm 145mm 450gr
The Power Injector can be installed free standing, on an even horizontal surface or wall mounted using the power injector’s wall mounting key holes. The following guidelines should be adhered to before cabling the Power Injector to the Ethernet source and Motorola device:
Environmental Specifications Operating Temperature 0°C to 40°C (32°F to 104°F) Storage Temperature -20°C to 70°C (-4°F to 158°F) Operating Humidity 10% to 93% Non-condensing Storage Humidity 10% to 93% Non-condensing Electrical Specifications Input Voltage Maximum Output Power Nominal Output Voltage Ethernet Interface Input (Data In)
Output (Data & Power Out)
- Verify the device receiving converged power and Ethernet from the Power Injector is a product approved by Motorola (AP100, AP200, AP300 and AP-5131).
- Do not block or cover airflow to the Power Injector.
- Keep the Power Injector away from excessive heat, humidity, vibration and dust.
90VAC to 264VAC (47Hz - 63Hz) .15.4 W 48VDC
Ethernet 10/100Base-T (RJ-45 female socket) Ethernet 10/100Base-T, plus 48VDC RJ-45 female socket, with DC voltage on pairs 7-8 and 4-5
- Port Status and Main power LED indicators
- The Power Injector is not a repeater, and does not amplify the Ethernet data signal. For optimal performance, ensure the Power Injector is placed as close as possible to the network data port. Do not configure the cable length between the Ethernet network source, the Power Injector and the Motorola AP beyond 100 meters (333ft).
Cabling the Power Injector To install the Power Injector to an Ethernet data source and Motorola device: Caution - Ensure AC power is supplied to the Power Injector using an AC cable with an appropriate ground connection approved for the country of operation. 1. Connect the Power Injector to an AC outlet (110VAC to 220VAC).
- Standalone or wall mount installation support
2. Connect RJ-45 Ethernet cable between the network data supply (host) and the Power Injector Data In connector.
- Interconnection option with other Power Injector units.
3. Connect a RJ-45 Ethernet cable between the Power Injector Data & Power Out connector and the Motorola device receiving converged power and Ethernet. Wireless LAN
(3)(4)(5)(6)
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
Ensure the cable length from the Ethernet source (host) to the Power Injector and Motorola device receiving converged power and Ethernet does not exceed 100 meters (333 ft).
A Power Injector port indicator is not illuminated and the Motorola AP does not operate 1. 2. 3. 4. 5. 6.
The Power Injector did not detect the AP and thus the port is not enabled. Ensure you are using a standard 5/5e/6, straight-wired cable with four pairs. Verify the input Ethernet cable is connected to the Power Injector Data In port. Verify the Motorola AP is connected to the Power Injector Data & Power port. Reconnect the Motorola AP to a different Power Injector. If the AP receives power, there is probably a faulty port or RJ-45 connection on the Power Injector. Verify there is not a short over any of the twisted pair cables or over the RJ-45 connectors.
Access Point receives power but no Ethernet 1. 2. 3. 4. 5.
The Power Injector has no On/Off power switch. The Power Injector receives power and is ready for Motorola device connection and operation as soon as AC power is applied.
Multiple Power Injector Installations Each Power Injector has a coupling rail designed to connect Power Injectors together to support multiple device installations. Align the power injectors and slide the units together using the coupling rail to connect the units. Cable each device as described in the Cabling the Power Injector section of this document. Only one Motorola device (AP 100, AP 200, AP 300 or AP-5131) can be powered from a single Power Injector.
Verify the Ethernet cable is connected to an active hub or switch port on the network. Verify the port indicator on the front panel is continuously illuminated. Verify you are using a standard UTP/FTP Category 5 straight (non-crossover) cabling with all four pairs. Ensure the Ethernet cable length is less than 100 meters from the Ethernet data source to the Power Injector. Reconnect the Motorola AP to a different Power Injector. If the AP receives power, there is probably a faulty port or RJ-45 connection on the Power Injector.
Outside North America, Motorola. Symbol Place Winnersh Triangle, Berkshire, RG41 5TP United Kingdom Telephone: 0800-328-2424 (Inside UK), +44 118 945 7529 (Outside UK)
Comprehensive on-line support is available at the Support Central site at http://www.symbol.com/support/. Support Central provides our customers with a wealth of information and online assistance including developer tools, software downloads, product manuals and online repair requests. Downloads http://www.symbol.com/downloads
Copyright
Motorola and the Symbol logo are registered trademarks of Symbol Technologies, Inc. Other product names mentioned in this guide may be trademarks or registered trademarks of their respective companies and are hereby acknowledged.
Patents This product is covered by one or more of the patents listed on: www.symbol.com/patents
Manuals http://www.symbol.com/manuals
Additional Information Obtain additional information by contacting Motorola at:
- 1-800-722-6234, inside North America
Motorola provides its customers with prompt and accurate customer support. Use Support Central as the primary contact for any technical problem, question or support issue involving Motorola products. If the Support Central specialists cannot solve a problem, access to all technical disciplines within Motorola becomes available for further assistance and support. Motorola Support Central responds to calls by email, telephone or fax within the time limits set forth in individual contractual agreements. When contacting Support Central, please provide the following information:
- +1-631-738-5200, in/outside North America
- http://www.motorola.com/
- Serial number of unit
- Model number or product name
- Software type and version number
(9)
The Power Injector demonstrates the following LED behavior under normal and/or problematic operating conditions:
Statement of Compliance Motorola hereby declares that this device is in compliance with all the applicable Directives, 89/336/EEC, 73/23/EEC. A Declaration of Conformity may be obtained from http:// www2.symbol.com/doc/
Copyright © 2007 by Motorola - All rights reserved.
Customer Support Web Sites
Customer Support
(7)
Power Injector LED Indicators
Marking and European Economic Area (EEA)
International Contacts
(11)
North American Contacts
Regulatory Information
Inside North America, contact Motorola at:
This device is approved under the Symbol Technologies brand; Symbol Technologies, Inc., is the Enterprise Mobility business of Motorola, Inc (“Motorola”).
For sales and product information: One Symbol Plaza Holtsville, New York 11742-1300 Telephone: 1-631-738-2400/1-800-SCAN 234 Fax: 1-631-738-5990
(13)
All devices are designed to comply with rules and regulations in locations they are sold and will be labeled as required. Any changes or modifications not expressly approved by Motorola, could void the user’s authority to operate the equipment.
For product support and service: Support Central Telephone: 1-800-653-5350, +1-631-738-6213 (Outside North America) Fax: 631-563-5410 Email: http://www.symbol.com/support
Local language translations are available at the following website: http://www.symbol.com/manuals. EMI Compliance: Category 5 foiled twisted-pair cables must be used to ensure compliance with Class B emission limits.
Radio Frequency Interference Requirements Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the Tested to Comply FCC rules. These limits are designed to provide reasonable With FCC Standards protection against harmful interference in a residential For Home or Office Use installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Symbol Technologies Inc.
LEDAC (Main)PortGreen (Steady)
Power Injector is receiving power from AC outlet
Indicates a device is connected to the Power Injector’s outgoing Data & Power cable
Green (Blinking)
Output voltage source is out of range
The Power Injector is overloaded or has a short circuit
Troubleshooting
- Reorient or relocate the receiving antenna
- Increase the separation between the equipment and receiver
The following potential Power Injector problem scenarios should be addressed as follows:
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected
Power Injector does not power up properly 1. 2. 3.
- Consult the dealer or an experienced radio/TV technician for assistance
Radio Frequency Interference Requirements – Canada
Verify the power cord power cord is operational for the intended country of operation Verify the voltage at the power inlet is between 100 and 240 VAC. Remove and reapply power to the Power Injector and verify the LED behavior during the powering sequence.
(8)
This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. (10)
(12)
(14)