The text of a manual · part 8 of 76
AP-51xx Access Point Product Reference Guide: Hardware Installation, pages 65 to 72
Pages 65 to 72 of 724, from AP-51xx Access Point Product Reference Guide
The original document is the PDF (7.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol AP-5131
Page 65
Hardware Installation
For standard 48-Volt Power Adapter (Part No. 50-14000-243R) and line cord installations: a. Connect RJ-45 Ethernet cable between the network data supply (host) and the AP-5131 LAN port. b. Verify the power adapter is correctly rated according the country of operation. c. Connect the power supply line cord to the power adapter. d. Attach the power adapter cable into the power connector on the AP-5131. e. Plug the power adapter into an outlet. NOTE If the AP-5131 is utilizing remote management antennae, a wire cover can be used to provide a clean finished look to the installation. Contact Motorola for more information. 9. Verify the behavior of the AP-5131 LEDs. For more information, see AP-5131 LED Indicators on page 2-23. The AP-5131 is ready to configure. For information on an AP-5131 default configuration, see Getting Started on page 3-1. For specific details on AP-5131 system configurations, see System Configuration on page 4-1.
2.7.3 Suspended Ceiling T-Bar Installations A suspended ceiling mount requires holding the AP-5131 up against the T-bar of a suspended ceiling grid and twisting the AP-5131 chassis onto the T-bar. The mounting hardware and tools (customer provided) required to install the AP-5131 on a ceiling T-bar consists of: • •
Safety wire (recommended) Security cable (optional)
To install the AP-5131 on a ceiling T-bar: 1. If required, loop a safety wire, with a diameter of at least 1.01 mm (.04 in.), but no more than 0.158 mm (.0625 in.), through the tie post (above the AP-5131’s console connector) and secure the loop. 2. If required, install and attach a security cable to the AP-5131 lock port. 3. Attach the radio antennae to their correct connectors.
2-17
Page 66
2-18
AP-51xx Access Point Product Reference Guide
!
CAUTION Both the Dual and Single Radio model AP-5131s use RSMA type antenna connectors. On a Dual Radio AP-5131, a single dot on the antenna connector indicates the primary antenna for both Radio 1 (2.4 GHz) and Radio 2 (5 GHz). Two dots designate the secondary antenna for both Radio 1 and Radio 2. On Single Radio models, a single dot on the antenna connector indicates the primary antenna for Radio 1, and two dots designate the secondary antenna for Radio 1
4. Cable the AP-5131 using either the Power Injector solution or an approved line cord and power supply.
!
CAUTION Do not supply power to the AP-5131 until the cabling of the unit is complete.
For Power Injector installations: a. Connect a RJ-45 Ethernet cable between the network data supply (host) and the Power Injector Data In connector. b. Connect a RJ-45 Ethernet cable between the Power Injector Data & Power Out connector and the AP-5131 LAN port. c. Ensure the cable length from the Ethernet source (host) to the Power Injector and AP-5131 does not exceed 100 meters (333 ft). The Power Injector has no On/Off power switch. The Power Injector receives power as soon as AC power is applied. For more information on using the Power Injector, see Power Injector and Power Tap Systems on page 2-10. For standard 48-Volt Power Adapter (Part No. 50-14000-243R) and line cord installations: a. Connect RJ-45 Ethernet cable between the network data supply (host) and the AP-5131 LAN port. b. Verify the power adapter is correctly rated according the country of operation. c. Connect the power supply line cord to the power adapter. d. Attach the power adapter cable into the power connector on the AP-5131. e. Plug the power adapter into an outlet. 5. Verify the behavior of the AP-5131 LEDs. For more information, see AP-5131 LED Indicators on page 2-23. 6. Align the bottom of the ceiling T-bar with the back of the AP-5131.
Page 67
Hardware Installation
7. Orient the AP-5131 chassis by its length and the length of the ceiling T-bar. 8. Rotate the AP-5131 chassis 45 degrees clockwise, or about 10 o’clock. 9. Push the back of the AP-5131 chassis on to the bottom of the ceiling T-bar.
!
CAUTION Ensure the safety wire and cabling used in the T-Bar AP-5131 installation is securely fastened to the building structure in order to provide a safe operating environment.
10. Rotate the AP-5131 chassis 45 degrees counter-clockwise. The clips click as they fasten to the T-bar.
11. The AP-5131 is ready to configure. For information on an AP-5131 default configuration, see Getting Started on page 3-1. For specific details on AP-5131 system configurations, see System Configuration on page 4-1. NOTE If the AP-5131 is utilizing remote management antennae, a wire cover can be used to provide a clean finished look to the installation. Contact Motorola for more information.
2-19
Page 68
2-20
AP-51xx Access Point Product Reference Guide
2.7.4 Above the Ceiling (Plenum) Installations An AP-5131 above the ceiling installation requires placing the AP-5131 above a suspended ceiling and installing the provided light pipe under the ceiling tile for viewing the rear panel status LEDs of the unit. An above the ceiling AP-5131 installation enables installations compliant with drop ceilings, suspended ceilings and industry standard tiles from .625 to .75 inches thick. NOTE The AP-5131 is Plenum rated to UL2043 and NEC1999 to support above the ceiling installations.
!
CAUTION Motorola does not recommend mounting the AP-5131 directly to any suspended ceiling tile with a thickness less than 12.7mm (0.5in.) or a suspended ceiling tile with an unsupported span greater than 660mm (26in.). Motorola strongly recommends fitting the AP-5131 with a safety wire suitable for supporting the weight of the device. The safety wire should be a standard ceiling suspension cable or equivalent steel wire between 1.59mm (.062in.) and 2.5mm (.10in.) in diameter.
The mounting hardware required to install the AP-5131 above a ceiling consists of: • • • • •
Light pipe Badge for light pipe Decal for badge Safety wire (strongly recommended) Security cable (optional)
To install the AP-5131 above a ceiling: 1. If possible, remove the adjacent ceiling tile from its frame and place it aside. 2. Install a safety wire, between 1.5mm (.06in.) and 2.5mm (.10in.) in diameter, in the ceiling space. 3. If required, install and attach a security cable to the AP-5131’s lock port. 4. Mark a point on the finished side of the tile where the light pipe is to be located. 5. Create a light pipe path hole in the target position on the ceiling tile. 6. Use a drill to make a hole in the tile the approximate size of the AP-5131 LED light pipe.
Page 69
Hardware Installation
!
CAUTION Motorola recommends care be taken not to damage the finished surface of the ceiling tile when creating the light pipe hole and installing the light pipe.
7. Remove the light pipe’s rubber stopper before installing the light pipe. 8. Connect the light pipe to the bottom of the AP-5131. Align the tabs and rotate approximately 90 degrees. Do not over tighten.
Light Pipe
Ceiling Tile Decal Badge
9. Snap the clips of the light pipe into the bottom of the AP-5131. 10. Fit the light pipe into hole in the tile from its unfinished side. 11. Place the decal on the back of the badge and slide the badge onto the light pipe from the finished side of the tile. 12. Attach the radio antennae to their correct connectors.
!
CAUTION Both the Dual and Single Radio model AP-5131s use RSMA type antenna connectors. On the Dual Radio AP-5131, a single dot on the antenna connector indicates the primary antenna for both Radio 1 (2.4 GHz) and Radio 2 (5 GHz). Two dots designate the secondary antenna for both Radio 1 and Radio 2. On Single Radio models, a single dot on the antenna connector indicates the primary antenna for Radio 1, and two dots designate the secondary antenna for Radio 1.
2-21
Page 70
2-22
AP-51xx Access Point Product Reference Guide
13. Attach safety wire (if used) to the AP-5131 safety wire tie point or security cable (if used) to the AP-5131’s lock port. 14. Align the ceiling tile into its former ceiling space. 15. Cable the AP-5131 using either the Power Injector solution or an approved line cord and power supply.
!
CAUTION Do not supply power to the AP-5131 until the cabling of the unit is complete.
For Power Injector installations: a. Connect a RJ-45 Ethernet cable between the network data supply (host) and the Power Injector Data In connector. b. Connect a RJ-45 Ethernet cable between the Power Injector Data & Power Out connector and the AP-5131 LAN port. c. Ensure the cable length from the Ethernet source (host) to the Power Injector and AP-5131 does not exceed 100 meters (333 ft). The Power Injector has no On/Off power switch. The Power Injector receives power as soon as AC power is applied. For more information on using the Power Injector, see Power Injector and Power Tap Systems on page 2-10. For standard 48-Volt Power Adapter (Part No. 50-14000-243R) and line cord installations: a. Connect a RJ-45 Ethernet cable between the network data supply (host) and the AP-5131 LAN port. b. Verify the power adapter is correctly rated according the country of operation. c. Connect the power supply line cord to the power adapter. d. Attach the power adapter cable into the power connector on the AP-5131. e. Plug the power adapter into an outlet. 16. Verify the behavior of the AP-5131 LED lightpipe. For more information, see AP-5131 LED Indicators on page 2-23. 17. Place the ceiling tile back in its frame and verify it is secure. The AP-5131 is ready to configure. For information on an AP-5131 default configuration, see Getting Started on page 3-1. For specific details on AP-5131 system configurations, see System Configuration on page 4-1.
Page 71
Hardware Installation
2.8 AP-5131 LED Indicators The AP-5131 utilizes seven LED indicators. Five LEDs display within four LED slots on the front of the AP-5131 (on top of the AP-5131 housing) and two LEDs (for above the ceiling installations) are located on the back of the device (the side containing the LAN, WAN and antenna connectors). 0OWER AND %RROR #ONDITIONS ,%$ $ATA /VER %THERNET A 2ADIO !CTIVITY 2ADIO !CTIVITY
The five LEDs on the top housing of the AP-5131 are clearly visible in table-top, wall and below ceiling installations. The five AP-5131 top housing LEDs have the following display and functionality:
Power Status
Solid white indicates the AP-5131 is adequately powered.
Error Conditions
Solid red indicates the AP-5131 is experiencing a problem condition requiring immediate attention.
Ethernet Activity
Flashing white indicates data transfers and Ethernet activity.
802.11a Radio Activity
Flickering amber indicates beacons and data transfers over the AP-5131 802.11a radio. Flickering green indicates beacons and data transfers over the AP-5131
802.11b/g Radio Activity 802.11b/g radio.
2-23
Page 72
2-24
AP-51xx Access Point Product Reference Guide
The LEDs on the rear of the AP-5131 are viewed using a single (customer installed) extended lightpipe, adjusted as required to suit above the ceiling installations. The LEDs displayed using the lightpipe have the following color display and functionality:
Boot and Power Status Solid white indicates the AP-5131 is adequately powered.
Error Conditions
Solid red indicates the AP-5131 is experiencing a problem condition requiring immediate attention.
Power and Error Conditions
Blinking red indicates the AP-5131 Rogue AP Detection feature has located a rogue device
2.9 Mounting an AP-5181 The AP-5181 can be connected to a pole or attach to a wall. Choose one of the following mounting options based on the physical environment of the coverage area. Do not mount the AP-5181 in a location that has not been approved in a site survey. Refer to the following, depending on how you intend to mount the AP-5181: • •
AP-5181 Pole Mounted Installations AP-5181 Wall Mounted Installations
2.9.1 AP-5181 Pole Mounted Installations Complete the following steps to mount the AP-5181 to a (1.5 to 18 inch diameter) steel pole or tube (using the mounting bracket): 1. Fit the edges of the V-shaped clamp parts into the slots on the flat side of the rectangular plate. 2. Place the V-shaped bracket clamp parts around the pole and tighten the nuts just enough to hold the bracket to the pole. (The bracket may need to be rotated around the pole during the antenna alignment process).