The text of a manual · part 7 of 76
AP-51xx Access Point Product Reference Guide: Hardware Installation, pages 57 to 64
Pages 57 to 64 of 724, from AP-51xx Access Point Product Reference Guide
The original document is the PDF (7.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol AP-5131
Page 57
Hardware Installation
Nominal Net Gain (dBi)
Part Number
Antenna Type
ML-2452-PNA7-01R
Panel Antenna (Dual-Band)
ML-2452-PNA5-01R
Sector Antenna (Dual-Band) 6.0
8.0
Description 2.4 - 2.5/4.9 - 5.99 GHz, 66 deg/60 deg Type N connector, with pigtail 2.3 - 2.4/4.9 - 5.9 GHz, 120 deg Sector Type N connector, with pigtail
The AP-5181 5 GHz antenna suite includes the following models: Nominal Net Gain (dBi)
Part Number
Antenna Type
ML-5299-FHPA6-01R
Omni-Directional Antenna
7.0
4.900-5.850 GHz, Type N connector, no pigtail
ML-5299-FHPA10-01R Omni-Directional Antenna
10.0
5.8 GHz, Type N connector, no pigtail
2.5 Power Options 2.5.1 AP-5131 Power Options The power options for the AP-5131 include: • • •
Power Injector (Part No. AP-PSBIAS-1P2-AFR) 48-Volt Power Supply (Part No. 50-14000-243R) Any 802.3af midspan device.
Description
2-9
Page 58
2-10
AP-51xx Access Point Product Reference Guide
2.5.2 AP-5181 Power Options The power options for the AP-5181 include:
! • • •
CAUTION An AP-5181 model access point cannot use the AP-5131 recommended 48-Volt Power Supply (Part No. 50-14000-243R). Motorola recommends the AP-PSBIAS-5181-01R Power Tap for use an AP-5181 and its intended outdoor deployment. Power Injector (Part No. AP-PSBIAS-1P2-AFR) Power Tap (Part No. AP-PSBIAS-5181-01R) Any 802.3af midspan device.
2.6 Power Injector and Power Tap Systems An AP-5131 or AP-5181 access point can receive power via an Ethernet cable connected to the access point’s LAN port (using 802.3af). When users purchase a WLAN solution, they often need to place access points in obscure locations. In the past, a dedicated power source was required for each access point in addition to the Ethernet infrastructure. This often required an electrical contractor to install power drops at each access point location. The Power Injector and Power Tap solutions merge power and Ethernet into one cable, reducing the burden of installation and allow optimal access point placement in respect to the intended radio coverage area. Both the Power Injector and Power Tap are integrated AC-DC converters requiring 110-220 VAC power to combine low-voltage DC with Ethernet data in a single cable connecting to the access point. The access point can only use a Power Injector or Power Tap when connecting the unit to the access point’s LAN port. The Power Injector (Part No. AP-PSBIAS-1P2-AFR) is included in certain AP-5131 kits. The AP-5181 Power Tap (Part No. AP-PSBIAS-5181-01R) is ordered separately and is intended for AP-5181 outdoor deployments. NOTE Though an AP-5181 can use the Power Injector solution (Part No. APPSBIAS-1P2-AFR), Motorola recommends using the AP-5181 Power Tap (Part No. AP-PSBIAS-5181-01R) designed especially for outdoor deployments.
Page 59
Hardware Installation
!
CAUTION The access point supports a 802.3af compliant power source (including non-Motorola power sources). However, using the wrong solution (including a POE system used on a legacy Motorola access point) could severely damage the access point and void the product warranty.
A separate Power Injector or Power Tap is required for each access point comprising the network.
2.6.1 Installing the Power Injector or Power Tap Refer to the following sections for information on planning, installing, and validating the installation: • • •
Preparing for Site Installation Cabling the Power Injector and Power Tap Power Injector LED Indicators
2.6.1.1 Preparing for Site Installation The Power Injector or Power Tap can be installed free standing, on an even horizontal surface or wall mounted using the unit’s wall mounting key holes. The following guidelines should be adhered to before cabling the Power Injector or Power Tap to an Ethernet source and an access point: • • •
Do not block or cover airflow to the Power Injector or Power Tap. Keep the unit away from excessive heat, humidity, vibration and dust. The Power Injector and Power Tap are not repeaters, and do not amplify the Ethernet data signal. For optimal performance, ensure the unit is placed as close as possible to the network data port.
2.6.1.2 Cabling the Power Injector and Power Tap To install a Power Injector or Power Tap to an Ethernet data source and access point:
!
CAUTION For Power Tap installations, an electrician is required to open the Power Tap unit, feed the power cable through the Line AC connector, secure the power cable to the unit’s three screw termination block and tighten the unit’s Line AC clamp (by hand) to ensure the power cable cannot be pulled from the Power Tap enclosure. Only a certified electrician should conduct the installation.
2-11
Page 60
2-12
AP-51xx Access Point Product Reference Guide
!
CAUTION Ensure AC power is supplied to the Power Injector or Power Tap (for AP-5181 installations) using an AC cable with an appropriate ground connection approved for the country of operation.
1. Connect an RJ-45 Ethernet cable between the network data supply (host) and the Power Injector’s Data In or the Power Tap’s DATA IN connector. 2. Connect an RJ-45 Ethernet cable between the Power Injector’s Data & Power Out connector or the Power Tap’s DATA/PWR OUT connector and the access point’s LAN port.
!
CAUTION Cabling the Power Injector to the access point’s WAN port renders the access point non-operational. Only use a Power Injector or Power Tap with the access point’s LAN port. Ensure the cable length from the Ethernet source (host) to the Power Tap (or Power Injector) and access point does not exceed 100 meters (333 ft). Neither the Power Tap or Power Injector has an On/Off switch. Each receives power as soon as AC power is applied.
3. For Power Tap installations, have a certified electrician open the Power Tap enclosure, feed the power cable through the unit’s LINE AC connector, secure the power cable to the unit’s three screw termination block and tighten the unit’s LINE AC clamp (by hand) to ensure the power cable cannot be pulled from the unit and is protected from the elements. 4. For Power Tap installations, attach a ground cable between the EARTH GROUND connector (on the back of the unit) to a suitable earth ground connection as defined by your local electrical code. 5. Verify all cable connections are complete before supplying power to the access point.
2.6.1.3 Power Injector LED Indicators NOTE The AP-5181 Power Tap (Part No. AP-PSBIAS-5181-01R) does not have LED indicators.
The Power Injector demonstrates the following LED behavior under normal and/or problematic operating conditions:
Page 61
Hardware Installation
LED Green (Steady)
AC (Main)
Port
Power Injector is receiving power from an Indicates a device is connected to the AC outlet. Power Injector’s outgoing Data & Power cable.
Green (Blinking) Output voltage source is out of range.
The Power Injector is overloaded or has a short circuit.
For more information and device specifications for the Power Injector, refer to the Power Injector Quick Install Guide (Part No. 72-70762-01) available from the Motorola Web site.
2.7 Mounting an AP-5131 The AP-5131 can rest on a flat surface, attach to a wall, mount under a suspended T-Bar or above a ceiling (plenum or attic). Choose one of the following mounting options based on the physical environment of the coverage area. Do not mount the AP-5131 in a location that has not been approved in a site survey. Refer to the following, depending on how you intend to mount the AP-5131: • • • •
Desk Mounted Installations Wall Mounted Installations Suspended Ceiling T-Bar Installations Above the Ceiling (Plenum) Installations
2.7.1 Desk Mounted Installations The desk mount option uses rubber feet allowing the unit to sit on most flat surfaces. The four (4) round rubber feet can be found in the AP-5131 (main) box in a separate plastic bag. To install the AP-5131 in a desk mount orientation: 1. Turn the AP-5131 upside down. 2. Attach the radio antennae to their correct connectors. The antenna protection plate cannot be used in a desk mount configuration, as the plate only allows antennas to be positioned in a downward orientation.
2-13
Page 62
2-14
AP-51xx Access Point Product Reference Guide
!
CAUTION Both the Dual and Single Radio model AP-5131’s use RSMA type antenna connectors. On the Dual Radio AP-5131, a single dot on the antenna connector indicates the primary antenna for both Radio 1 (2.4 GHz) and Radio 2 (5 GHz). Two dots designate the secondary antenna for both Radio 1 and Radio 2. On Single Radio models, a single dot on the antenna connector indicates the primary antenna for Radio 1, and two dots designate the secondary antenna for Radio 1.
3. Remove the backings from the four (4) rubber feet and attach them to the four rubber feet recess areas on the AP-5131.
4. Cable the AP-5131 using either the Power Injector solution or an approved line cord and power supply.
!
CAUTION Do not supply power to the AP-5131 until the cabling of the unit is complete.
For Power Injector installations: a. Connect a RJ-45 Ethernet cable between the network data supply (host) and the power injector Data In connector. b. Connect a RJ-45 Ethernet cable between the Power Injector Data & Power Out connector and the AP-5131 LAN port. c. Ensure the cable length from the Ethernet source (host) to the Power Injector and AP-5131 does not exceed 100 meters (333 ft). The Power Injector has no On/Off power switch. The Power Injector receives power as soon as AC power is applied. For more information on using the Power Injector, see Power Injector and Power Tap Systems on page 2-10.
Page 63
Hardware Installation
For standard 48-Volt power adapter (Part No. 50-14000-243R) and line cord installations: a. Connect RJ-45 Ethernet cable between the network data supply (host) and the AP-5131 LAN port. b. Verify the power adapter is correctly rated according the country of operation. c. Connect the power supply line cord to the power adapter. d. Attach the power adapter cable into the power connector on the AP-5131. e. Plug the power adapter into an outlet. 5. Verify the behavior of the AP-5131 LEDs. For more information, see AP-5131 LED Indicators on page 2-23. 6. Return the AP-5131 to an upright position and place it in the location you wish it to operate. Ensure the AP-5131 is sitting evenly on all four rubber feet. The AP-5131 is ready to configure. For information on an AP-5131 default configuration, see Getting Started on page 3-1. For specific details on AP-5131 system configurations, see System Configuration on page 4-1.
2.7.2 Wall Mounted Installations Wall mounting requires hanging the AP-5131 along its width (or length) using the pair of slots on the bottom of the unit and using the AP-5131 itself as a mounting template for the screws. The AP-5131 can be mounted onto any plaster or wood wall surface. The mounting hardware and tools (customer provided) required to install the AP-5131 on a wall consists of: •
• •
Two Phillips pan head self-tapping screws (ANSI Standard) #6-18 X 0.875in. Type A or AB Self-Tapping screw, or (ANSI Standard Metric) M3.5 X 0.6 X 20mm Type D Self-Tapping screw Two wall anchors Security cable (optional)
To mount the AP-5131 on a wall: 1. Orient the AP-5131 on the wall by its width or length. 2. Using the arrows on one edge of the case as guides, move the edge to the midline of the mounting area and mark points on the midline for the screws. 3. At each point, drill a hole in the wall, insert an anchor, screw into the anchor the wall mounting screw and stop when there is 1mm between the screw head and the wall.
2-15
Page 64
2-16
AP-51xx Access Point Product Reference Guide
If pre-drilling a hole, the recommended hole size is 2.8mm (0.11in.) if the screws are going directly into the wall and 6mm (0.23in.) if wall anchors are being used. 4. If required, install and attach a security cable to the AP-5131 lock port. 5. Place the large corner of each of the mount slots over the screw heads. 6. Slide the AP-5131 down along the mounting surface to hang the mount slots on the screw heads. 7. Attach the radio antennae to their correct connectors.
!
CAUTION Both the Dual and Single Radio model AP-5131s use RSMA type antenna connectors. On the Dual Radio AP-5131, a single dot on the antenna connector indicates the primary antenna for both Radio 1 (2.4 GHz) and Radio 2 (5 GHz). Two dots designate the secondary antenna for both Radio 1 and Radio 2. On Single Radio models, a single dot on the antenna connector indicates the primary antenna for Radio 1, and two dots designate the secondary antenna for Radio 1.
8. Cable the AP-5131 using either the Power Injector solution or an approved line cord and power supply. NOTE The access point must be mounted with the RJ45 cable connector oriented upwards to ensure proper operation.
!
CAUTION Do not supply power to the AP-5131 until the cabling of the unit is complete.
For Power Injector installations: a. Connect a RJ-45 Ethernet cable between the network data supply (host) and the Power Injector Data In connector. b. Connect a RJ-45 Ethernet cable between the Power Injector Data & Power Out connector and the AP-5131 LAN port. c. Ensure the cable length from the Ethernet source (host) to the Power Injector and AP-5131 does not exceed 100 meters (333 ft). The Power Injector has no On/Off power switch. The Power Injector receives power as soon as AC power is applied. For more information on using the Power Injector, see Power Injector and Power Tap Systems on page 2-10.