Page 133

System Configuration

Add

Click Add to create a new SNMP v1/v2c Trap Configuration entry.

SNMP Version

Use the SNMP Version drop-down menu to specify v1 or v2. Some SNMP clients support only SNMP v1 traps, while others support SNMP v2 traps and possibly both, verify the correct traps are in use with clients that support them.

3. Configure the SNMP v3 Trap Configuration field (if SNMP v3 Traps are used) to modify the following: Add

Click Add to create a new SNMP v3 Trap Configuration entry.

Delete

Select Delete to remove an entry for an SNMP v3 user.

Destination IP

Specify a numerical (non DNS name) destination IP address for receiving the traps sent by the access point SNMP agent.

Port

Specify a destination User Datagram Protocol (UDP) port for receiving traps.

Username

Enter a username specific to the SNMP-capable client receiving the traps.

Security Level

Use the Security Level drop-down menu to specify a security level of noAuth (no authorization), AuthNoPriv (authorization without privacy), or AuthPriv (authorization with privacy). The “NoAuth” setting specifies no login authorization or encryption for the user. The “AuthNoPriv” setting requires login authorization, but no encryption. The “AuthPriv” setting requires login authorization and uses the Data Encryption Standard (DES).

Passwords

Select Passwords to display the Password Settings screen for specifying authentication and password settings for an SNMP v3 user. The maximum password length is 11 characters. Use the Authentication Algorithm drop-down menu to specify MD5 or SHA1 as the authentication algorithm. Use the Privacy Algorithm drop-down menu to define an algorithm of DES or AES-128bit. If entering the same username on the SNMP Traps and SNMP Access screens, the password entered on the SNMP Traps page overwrites the password entered on the SNMP Access page. To avoid this problem, enter the same password on both pages.

4. Click Apply to save any changes to the SNMP Trap Configuration screen. Navigating away from the screen without clicking the Apply button results in all changes being lost.

4-37

Page 134

4-38

AP-51xx Access Point Product Reference Guide

5. Click Undo Changes (if necessary) to undo any changes made. Undo Changes reverts the settings displayed on SNMP Trap Configuration screen to the last saved configuration. 6. Click Logout to securely exit the access point Access Point applet. A prompt displays confirming the logout before the applet is closed.

4.5.3 Configuring Specific SNMP Traps Use the SNMP Traps screen to enable specific traps on the access point. Motorola recommends defining traps to capture unauthorized devices operating within the access point coverage area. Trap configuration depends on the network machine that receives the generated traps. SNMP v1/v2c and v3 trap configurations function independently. In a mixed SNMP environment, traps can be sent using configurations for both SNMP v1/v2c and v3. To configure specific SNMP traps on the access point: 1. Select System Configuration - > SNMP Access - > SNMP Traps from the menu tree.

2. Configure the MU Traps field to generate traps for MU associations, MU association denials and MU authentication denials. When a trap is enabled, a trap is sent every 10 seconds until the condition no longer exists.

Page 135

System Configuration

MU associated

Generates a trap when an MU becomes associated with one of the access point’s WLANs.

MU unassociated

Generates a trap when an MU becomes unassociated with (or gets dropped from) one of the access point’s WLANs.

MU denied association

Generates a trap when an MU is denied association to a access point WLAN. Can be caused when the maximum number of MUs for a WLAN is exceeded or when an MU violates the access point’s Access Control List (ACL).

MU denied authentication

Generates a trap when an MU is denied authentication on one of the AP’s WLANs. Can be caused by the MU being set for the wrong authentication type for the WLAN or by an incorrect key or password.

3. Configure the SNMP Traps field to generate traps when SNMP capable MUs are denied authentication privileges or are subject of an ACL violation. When a trap is enabled, a trap is sent every 5 seconds until the condition no longer exists. SNMP authentication Generates a trap when an SNMP-capable client is denied access failures to the access point’s SNMP management functions or data. This can result from an incorrect login, or missing/incorrect user credentials. SNMP ACL violation

Generates a trap when an SNMP client cannot access SNMP management functions or data due to an Access Control List (ACL) violation. This can result from a missing/incorrect IP address entered within the SNMP Access Control screen.

4-39

Page 136

4-40

AP-51xx Access Point Product Reference Guide

4. Configure the Network Traps field to generate traps when the access point’s link status changes or when the AP’s firewall detects a DOS attack. Physical port status change

Generates a trap whenever the status changes on the access point. The physical port status changes when a link is lost between the access point and a connected device.

DynDNS Update

Generates a trap whenever domain name information is updated as a result of the IP address associated with that domain being modified.

Denial of service (DOS) attempts

Generates a trap whenever a Denial of Service (DOS) attack is detected by the access point firewall. A new trap is sent at the specified interval until the attack has stopped.

Send trap every

Defines the interval in seconds the access point uses to generate a trap until the Denial of Service attack is stopped. Default is 10 seconds.

5. Configure the System Traps field to generate traps when the access point re-initializes during transmission, saves its configuration file. When a trap is enabled, a trap is sent every 5 seconds until the condition no longer exists. System Cold Start

Generates a trap when the access point re-initializes while transmitting, possibly altering the SNMP agent's configuration or protocol entity implementation.

Configuration Changes

Generates a trap whenever changes to the access point’s configuration file are saved.

Rogue AP Detection

Generates a trap if a Rogue AP is detected by the access point.

AP Radar Detection

Generates a trap if an AP is detected using a form of radar detection.

WPA Counter Measure

Generates a trap if an attack is detected against the WPA Key Exchange Mechanism.

MU Hotspot Status

Generates a trap when a change to the status of MU hotspot member is detected.

VLAN

Generates a trap when a change to a VLAN state is detected.

LAN Monitor

Generates a trap when a change to the LAN monitoring state is detected.

Page 137

System Configuration

6. Refer to the Set All Traps field to use a single location to either enable or disable each trap listed within the SNMP Traps screen. Enable All

Select this button to enable each trap defined within the SNMP Traps screen. Once the changes are applied, each event listed will generate a trap upon its occurrence.

Disable All

Select this button to disable each trap defined within the SNMP Traps screen. Once the changes are applied, none of the events listed will generate a trap upon their occurrence.

7. Click Apply to save any changes to the SNMP Traps screen. Navigating away from the screen without clicking the Apply button results in all changes to the screen being lost. 8. Click Undo Changes (if necessary) to undo any changes made. Undo Changes reverts the settings displayed on SNMP Traps screen to the last saved configuration. 9. Click Logout to securely exit the access point Access Point applet. A prompt displays confirming the logout before the applet is closed.

4.5.4 Configuring SNMP RF Trap Thresholds Use the SNMP RF Trap Threshold screen as a means to track RF activity and the access point’s radio and associated MU performance. SNMP RF Traps are sent when RF traffic exceeds defined limits set in the RF Trap Thresholds field of the SNMP RF Traps screen. Thresholds are displayed for the access point, WLAN, selected radio and the associated MU. To configure specific SNMP RF Traps on the access point: 1. Select System Configuration - > SNMP Access - > SNMP RF Trap Thresholds from the menu tree.

4-41

Page 138

4-42

AP-51xx Access Point Product Reference Guide

2. Configure the RF Trap Thresholds field to define device threshold values for SNMP traps. NOTE Average Bit Speed,% of Non-Unicast, Average Signal, Average Retries,% Dropped and % Undecryptable are not access point statistics.

Pkts/s

Enter a maximum threshold for the total throughput in Pps (Packets per second).

Throughput

Set a maximum threshold for the total throughput in Mbps (Megabits per second).

Average Bit Speed

Enter a minimum threshold for the average bit speed in Mbps (Megabits per second).

Average Signal

Enter a minimum threshold for the average signal strength in dBm for each device.

Page 139

System Configuration

Average Retries

Set a maximum threshold for the average number of retries for each device.

% Dropped

Enter a maximum threshold for the total percentage of packets dropped for each device. Dropped packets can be caused by poor RF signal or interference on the channel.

% Undecryptable

Define a maximum threshold for the total percentage of packets undecryptable for each device. Undecryptable packets can be the result of corrupt packets, bad CRC checks or incomplete packets.

Associated MUs

Set a maximum threshold for the total number of MUs associated with each device.

3. Configure the Minimum Packets field to define a minimum packet throughput value for trap generation. Minimum number of Enter the minimum number of packets that must pass through the packets required for a device before an SNMP rate trap is sent. Motorola recommends trap to fire using the default setting of 1000 as a minimum setting for the field.

4. Click Apply to save any changes to the SNMP RF Traps screen. Navigating away from the screen without clicking the Apply button results in all changes to the screen being lost. 5. Click Undo Changes (if necessary) to undo any changes made. Undo Changes reverts the settings displayed on SNMP RF Traps screen to the last saved configuration. 6. Click Logout to securely exit the access point Access Point applet. A prompt displays confirming the logout before the applet is closed.

4.6 Configuring Network Time Protocol (NTP) Network Time Protocol (NTP) manages time and/or network clock synchronization in the access pointmanaged network environment. NTP is a client/server implementation. The access point (an NTP client) periodically synchronizes its clock with a master clock (an NTP server). For example, the access point resets its clock to 07:04:59 upon reading a time of 07:04:59 from its designated NTP server.

4-43

Page 140

4-44

AP-51xx Access Point Product Reference Guide

Time synchronization is recommended for the access point’s network operations. For sites using Kerberos authentication, time synchronization is required. Use the Date and Time Settings screen to enable NTP and specify the IP addresses and ports of available NTP servers. NOTE The current time is not set accurately when initially connecting to the access point. Until a server is defined to provide the access point the correct time, or the correct time is manually set, the access point displays 1970-01-01 00:00:00 as the default time.

!

CAUTION If using the Radius time-based authentication feature to authenticate access point user permissions, ensure UTC has been selected from the Date and Time Settings screen’s Time Zone field. If UTC is not selected, time based authentication will not work properly. For information on configuring Radius time-based authentication, see Defining User Access Permissions by Group on page 6-76.

To manage clock synchronization on the access point: 1. Select System Configuration - > Date/Time from the access point menu tree.

Page 141

System Configuration

2. From within the Current Time field, click the Refresh button to update the time since the screen was displayed by the user. The Current Time field displays the current time based on the access point system clock. If NTP is disabled or if there are no servers available, the system time displays the access point uptime starting at 1970-01-01 00:00:00, with the time and date advancing. 3. Select the Set Date/Time button to display the Manual Date/Time Setting screen. This screen enables the user to manually enter the access point’s system time using a Year-Month-Day HH:MM:SS format. This option is disabled when the Enable NTP checkbox has been selected, and therefore should be viewed as a second means to define the access point system time. 4. If using the Manual Date/Time Setting screen to define the access point’s system time, refer to the Time Zone field to select the time used to use as complimentary information to the information entered within the Manual Date/Time Setting screen.

4-45