Page 124
4-28
AP-51xx Access Point Product Reference Guide
NOTE The Symbol-AP-5131-MIB contains the majority of the information contained within the Symbol-CC-WS2000-MIB-2.0 file. This feature rich information has been validated with the Motorola WS2000 and proven reliable. The remaining portion of the Symbol-AP-5131-MIB contains supplemental information unique to the access point feature set. If using the Symbol-CC-WS2000-MIB-2.0 and/or Symbol-AP-5131-MIB to configure the AP-5131, use the table below to locate the MIB where the feature can be configured. Feature
MIB
Feature
MIB
LAN Configuration
Symbol-AP-5131-MIB
Subnet Configuration Symbol-CC-WS2000-MIB-2.0
VLAN Configuration
Symbol-AP-5131-MIB
DHCP Server Configuration
Symbol-CC-WS2000-MIB-2.0
802.1x Port Authentication
Symbol-AP-5131-MIB
Advanced DHCP Server configuration
Symbol-CC-WS2000-MIB-2.0
Ethernet Type Filter Configuration
Symbol-AP-5131-MIB
WAN IP Configuration Symbol-CC-WS2000-MIB-2.0
Wireless Configuration
Symbol-AP-5131-MIB
PPP Over Ethernet
Symbol-CC-WS2000-MIB-2.0
Security Configuration Symbol-AP-5131-MIB
NAT Address Mapping Symbol-CC-WS2000-MIB-2.0
MU ACL Configuration Symbol-AP-5131-MIB
VPN Tunnel Configuration
Symbol-CC-WS2000-MIB-2.0
QOS Configuration
Symbol-AP-5131-MIB
VPN Tunnel status
Symbol-CC-WS2000-MIB-2.0
Radio Configuration
Symbol-AP-5131-MIB
Content Filtering
Symbol-CC-WS2000-MIB-2.0
Bandwidth Management
Symbol-AP-5131-MIB
Rogue AP Detection
Symbol-CC-WS2000-MIB-2.0
SNMP Trap Selection Symbol-AP-5131-MIB
Firewall Configuration Symbol-CC-WS2000-MIB-2.0
SNMP RF Trap Thresholds
Symbol-AP-5131-MIB
LAN to WAN Access
Config Import/Export
Symbol-AP-5131-MIB
Advanced LAN Access Symbol-CC-WS2000-MIB-2.0
MU Authentication Stats
Symbol-AP-5131-MIB
Router Configuration
Symbol-CC-WS2000-MIB-2.0
Symbol-CC-WS2000-MIB-2.0
Page 125
System Configuration
WNMP Ping Configuration
Symbol-AP-5131-MIB
System Settings
Symbol-CC-WS2000-MIB-2.0
Known AP Stats
Symbol-AP-5131-MIB
AP 5131 Access
Symbol-CC-WS2000-MIB-2.0
Flash LEDs
Symbol-AP-5131-MIB
Certificate Mgt
Symbol-CC-WS2000-MIB-2.0
Automatic Update
Symbol-AP-5131-MIB
SNMP Access Configuration
Symbol-CC-WS2000-MIB-2.0
SNMP Trap Configuration
Symbol-CC-WS2000-MIB-2.0
NTP Server Configuration
Symbol-CC-WS2000-MIB-2.0
Logging Configuration Symbol-CC-WS2000-MIB-2.0 Firmware Update
Symbol-CC-WS2000-MIB-2.0
Wireless Stats
Symbol-CC-WS2000-MIB-2.0
Radio Stats
Symbol-CC-WS2000-MIB-2.0
MU Stats
Symbol-CC-WS2000-MIB-2.0
Automatic Update
Symbol-CC-WS2000-MIB-2.0
SNMP allows a network administrator to manage network performance, find and solve network problems, and plan for network growth. The access point supports SNMP management functions for gathering information from its network components, communicating that information to specified users and configuring the access point. All the fields available within the access point are also configurable within the MIB. The access point SNMP agent functions as a command responder and is a multilingual agent responding to SNMPv1, v2c and v3 managers (command generators). The factory default configuration maintains SNMPv1/2c support of the community names, hence providing backward compatibility. SNMP v1/v2c community definitions and SNMP v3 user definitions work independently, and both use the Access Control List (ACL) of the SNMP Access Control sub-screen. Use the SNMP Access screen to define SNMP v1/v2c community definitions and SNMP v3 user definitions. SNMP version 1 (v1) provides a strong network management system, but its security is relatively weak. The improvements in SNMP version 2c (v2c) do not include the attempted security enhancements of other version-2 protocols. Instead, SNMP v2c defaults to SNMP-standard
4-29
Page 126
4-30
AP-51xx Access Point Product Reference Guide community strings for read-only and read/write access. SNMP version 3 (v3) further enhances protocol features, providing much improved security. SNMP v3 encrypts transmissions and provides authentication for users generating requests. To configure SNMP v1/v2c community definitions and SNMP v3 user definitions for the access point: 1. Select System Configuration - > SNMP Access from the access point menu tree.
SNMP v1/v2c community definitions allow read-only or read/write access to access point management information. The SNMP community includes users whose IP addresses are specified on the SNMP Access Control screen. A read-only community string allows a remote device to retrieve information, while a read/ write community string allows a remote device to modify settings. Motorola recommends considering adding a community definition using a site-appropriate name and access level. Set up a read/write definition (at a minimum) to facilitate full access by the access point administrator.
Page 127
System Configuration
2. Configure the SNMP v1/v2 Configuration field (if SNMP v1/v2 is used) to add or delete community definitions, name the community, specify the OID and define community access. Add
Click Add to create a new SNMP v1/v2c community definition.
Delete
Select Delete to remove a SNMP v1/v2c community definition.
Community
Use the Community field to specify a site-appropriate name for the community. The name is required to match the name used within the remote network management software.
OID
Use the OID (Object Identifier) pull-down list to specify a setting of All or a enter a Custom OID. Select All to assign the user access to all OIDs in the MIB. The OID field uses numbers expressed in dot notation.
Access
Use the Access pull-down list to specify read-only (R) access or read/write (RW) access for the community. Read-only access allows a remote device to retrieve access point information, while read/write access allows a remote device to modify access point settings.
3. Configure the SNMP v3 User Definitions field (if SNMP v3 is used) to add and configure SNMP v3 user definitions. SNMP v3 user definitions allow read-only or read/write access to management information as appropriate. Add
Click Add to create a new entry for an SNMP v3 user.
Delete
Select Delete to remove an entry for an SNMP v3 user.
Username
Specify a username by typing an alphanumeric string of up to 31 characters.
Security Level
Use the Security Level area to specify a security level of noAuth (no authorization), AuthNoPriv (authorization without privacy), or AuthPriv (authorization with privacy). The NoAuth setting specifies no login authorization or encryption for the user. The AuthNoPriv setting requires login authorization, but no encryption. The AuthPriv setting requires login authorization and uses the Data Encryption Standard (DES) protocol.
4-31
Page 128
4-32
AP-51xx Access Point Product Reference Guide
OID
Use the OID (Object Identifier) area to specify a setting of All or enter a Custom OID. Select All to assign the user access to all OIDs in the MIB. The OID field uses numbers expressed in dot notation.
Passwords
Select Passwords to display the Password Settings screen for specifying authentication and password settings for an SNMP v3 user. The maximum password length is 11 characters. Use the Authentication Algorithm drop-down menu to specify MD5 or SHA1 as the authentication algorithm. Use the Privacy Algorithm drop-down menu to define an algorithm of DES or AES-128bit. When entering the same username on the SNMP Traps and SNMP Access screens, the password entered on the SNMP Traps page overwrites the password entered on the SNMP Access page. To avoid this problem, enter the same password on both pages.
Access
Use the Access pull-down list to specify read-only (R) access or read/write (RW) access for a user. Read-only access permits a user to retrieve access point information, while read/write access allows a user to modify access pointsettings.
4. Specify the users who can read and optionally modify the SNMP-capable client. SNMP Access Control Click the SNMP Access Control button to display the SNMP Access Control screen for specifying which users can read SNMP-generated information and potentially modify related settings from an SNMP-capable client. The SNMP Access Control screen's Access Control List (ACL) uses Internet Protocol (IP) addresses to restrict access to the AP’s SNMP interface. The ACL applies to both SNMP v3 user definitions and SNMP v1/v2c community definitions. For detailed instructions of configuring SNMP user access and modification privileges, see Configuring SNMP Access Control on page 4-33.
5. If configuring SNMP v3 user definitions, set the SNMP v3 engine ID. AP-51xx SNMP v3 Engine ID
The access point SNMP v3 Engine ID field lists the unique SNMP v3 Engine ID for the access point. This ID is used in SNMP v3 as the source for a trap, response or report. It is also used as the destination ID when sending get, getnext, getbulk, set or inform commands.
Page 129
System Configuration
6. Click Apply to save any changes to the SNMP Access screen. Navigating away from the screen without clicking the Apply button results in all changes to the screen being lost. 7. Click Undo Changes (if necessary) to undo any changes made. Undo Changes reverts the settings displayed on the SNMP Access screen to the last saved configuration. 8. Click Logout to securely exit the access point Access Point applet. A prompt displays confirming the logout before the applet is closed. For additional SNMP configuration information, see: • • • •
Configuring SNMP Access Control Enabling SNMP Traps Configuring Specific SNMP Traps Configuring SNMP RF Trap Thresholds
4.5.1 Configuring SNMP Access Control Use the SNMP Access Control screen (as launched from the SNMP Access screen) to specify which users can read SNMP generated information and, if capable, modify related settings from an SNMP-capable client. Use the SNMP Access Control screen's Access Control List (ACL) to limit, by Internet Protocol (IP) address, who can access the access point SNMP interface. NOTE The ACL applies to both SNMP v3 user definitions and SNMP v1/v2c community definitions on the access point SNMP Access screen.
To configure SNMP user access control for the access point: 1. Select System Configuration - > SNMP Access from the access point menu tree. Click on the SNMP Access Control button from within the SNMP Access screen.
4-33
Page 130
4-34
AP-51xx Access Point Product Reference Guide
2. Configure the SNMP Access Control screen to add the IP addresses of those users receiving SNMP access. Access Control List
Enter Start IP and End IP addresses (numerical addresses only, no DNS names supported) to specify a range of user that can access the access point SNMP interface. An SNMP-capable client can be set up whereby only the administrator (for example) can use a read/ write community definition. Use just the Starting IP Address column to specify a single SNMP user. Use both the Starting IP Address and Ending IP Address columns to specify a range of addresses for SNMP users. To add a single IP address to the ACL, enter the same IP address in the Start IP and End IP fields. Leave the ACL blank to allow access to the SNMP interface from the IP addresses of all authorized users.
Add
Click Add to create a new ACL entry.
Edit
Click Edit to revise an existing ACL entry.
Delete
Click Delete to remove a selected ACL entry for one or more SNMP users.
Page 131
System Configuration
OK
Click Ok to return to the SNMP Access screen. Click Apply within the SNMP Access screen to save any changes made on the SNMP Access Control screen.
Cancel
Click Cancel to undo any changes made on the SNMP Access Control screen. This reverts all settings for this screen to the last saved configuration.
4.5.2 Enabling SNMP Traps SNMP provides the ability to send traps to notify the administrator that trap conditions are met. Traps are network packets containing data relating to network devices, or SNMP agents, that send the traps. SNMP management applications can receive and interpret these packets, and optionally can perform responsive actions. SNMP trap generation is programmable on a trap-by-trap basis. Use the SNMP Traps Configuration screen to enable traps and to configure appropriate settings for reporting this information. Trap configuration depends on the network machine that receives the generated traps. SNMP v1/v2c and v3 trap configurations function independently. In a mixed SNMP environment, generated traps can be sent using configurations for both SNMP v1/v2c and v3. To configure SNMP traps on the access point: 1. Select System Configuration - > SNMP Access - > SNMP Trap Configuration from the access point menu tree.
4-35
Page 132
4-36
AP-51xx Access Point Product Reference Guide
2. Configure the SNMP v1/v2c Trap Configuration field (if SNMP v1/v2c Traps are used) to modify the following: Add
Click Add to create a new SNMP v1/v2c Trap Configuration entry.
Delete
Click Delete to remove a selected SNMP v1/v2c Trap Configuration entry.
Destination IP
Specify a numerical (non DNS name) destination IP address for receiving the traps sent by the access point SNMP agent.
Port
Specify a destination User Datagram Protocol (UDP) port for receiving traps. The default is 162.
Community
Enter a community name specific to the SNMP-capable client that receives the traps.